Discuter avec un expert

DisplayPort Design & Test Information Resource Center

DisplayPort is the new digital display interface for computers, monitors and home-theater systems aimed at lower implementation costs and improving video performance. As a technology, DisplayPort, is now penetrating embedded and consumer electronics applications and recently a new version, MYDP, has been proposed to be a mobile interface to televisions to stream high definition content. Specifications and compliance tests are defined by the Video Electronic Standards Association (VESA) and products are tested according to a Compliance Test Specification (CTS) and are certified at specific third party Test Houses such as Allion, Granite River Labs and China Electronics Standards Institute (CESI). While the signaling is not compatible with HDMI and DVI, DisplayPort supports an interoperability mode (Dual mode) to HDMI through a minimal cost dongle that performs level translation.

Agilent is an active member of VESA, with consistent participation in DisplayPort workshops and specification issues. The resources you find here will provide you with an overview of DisplayPort design, understand the latest measurement techniques, and illustrate design and debug approaches.

The following table shows the different standards associated with DisplayPort

  Standard
DisplayPort
eDP iDP MYDP
Type Box-to-Box One Unit
(Laptops, Games,
etc)
LVDS replacement
internal
Portable-to-TV
Lanes 1,2 or 4 1,2 or 4 4 or 8 1
Bit
Rate
1.62, 2.7, 5.4 1.62, 2.7, 5.4 3.24 or 3.78 1.62, 2.7, 5.4
Version V1.2a V1.3/V1.4 V1.1 V1.0

 The resources you find here will provide you with an overview of DisplayPort design, understand the latest measurement techniques, and illustrate design and debug approaches. Agilent – achieve your best design.

Explorer les vidéos YouTube 

1-18 sur 18

Sort:
Oscilloscope Probe Switching - BitifEye 
Oscilloscope Probe Switching Solution from BitifEye and Agilent.

Brefs de solution 2014-04-09

 
J-BERT N4903B High-Performance Serial BERT - Data Sheet 
Updated J-BERT N4903B data sheet revision 1.3. Especially PCIe3 related enhancements covered by our PR in Jan 2013. Also covers all enhancements since SW releases 6.80 to 7.40

Fiche signalétique 2013-11-25

MOI for DisplayPort PHY CTS 1.2b Sink Tests 
This document is provided "AS IS" and without any warranty of any kind, including, without limitation, any express or implied warranty of non-infringement, merchantability or fitness for a particular purpose. In no event shall VESA™ or any member of VESA be liable for any direct, indirect, special, exemplary, punitive, or consequential damages, including, without limitation, lost profits, even if advised of the possibility of such damages. This material is provided for reference only. VESA does not endorse any vendor’s equipment including equipment outlined in this document.

Notes d’application 2013-03-21

PDF PDF 7.99 MB
MOI for DisplayPort PHY CTS 1.2b Source Testing  
This document is provided "AS IS" and without any warranty of any kind, including, without limitation, any expressed or implied warranty of non-infringement, merchantability or fitness for a particular purpose. In no event shall VESA™ or any member of VESA be liable for any direct, indirect, special, exemplary, punitive, or consequential damages, including, without limitation, lost profits, even if advised of the possibility of such damages. This material is provided for reference only. VESA does not endorse any vendor’s equipment, including equipment outlined in this document.

Notes d’application 2013-03-21

PDF PDF 5.63 MB
DisplayPort Cable-Connector Compliance Test - Test Solution Overview Using the ENA Option TDR 
This describes how to make measurements of VESA DisplayPort Cable & Connector Compliance Tests by using the Agilent E5071C ENA Option TDR.

Présentation technique 2013-02-18

PDF PDF 2.26 MB
Agilent Method of Implementation (MOI) for DisplayPort Cable-Connector Assembly Compliance Test 
Agilent Method of Implementation (MOI) for DisplayPort Cable-Connector Assembly Compliance Test Using Agilent E5071C ENA Network Analyzer Option TDR

Notes d’application 2013-02-18

PDF PDF 1.29 MB
DisplayPort 1.2 Link Layer Testing - FuturePlus 
DisplayPort 1.2 Link Layer Testing Solution from FuturePlus and Agilent.

Brefs de solution 2013-01-26

 
Crossing the Digital-Analog Divide - White Paper 
This white paper helps to better understand how to cope with the physical nature of signals that we might prefer to think of as bits, nibbles and bytes, let's start with an ideal digital waveform.

Notes d’application 2012-05-02

PDF PDF 6.46 MB
W2642A DisplayPort AUX Channel Controller 
Complete your DisplayPort toolset with test automation and AUX channel control capability

Fiche signalétique 2010-09-20

PDF PDF 870 KB
HDMI and DisplayPort Design and Test - A Better Way Brochure 
Brochure covering Agilent's HDMI and Displayport test solutions portfolio and applications, discussing measurement challenges and showing how the test solutions and services address these.

Brochure 2010-05-20

PDF PDF 1.37 MB
Method of Implementation (MOI) for DisplayPort Sink Compliance Test - Application Note 
Method of Implementation (MOI) for DisplayPort Sink Compliance Test

Notes d’application 2008-08-18

PDF PDF 1.87 MB
Jitter Solutions for Telecom, Enterprise, and Digital Designs - Brochure 
Complete solutions for characterization and test of jitter in high-speed digital transmission systems, high-speed I/O connections, and buses.

Brochure 2008-06-25

PDF PDF 3.49 MB
Agilent Technologies' DisplayPort Sink Test Platform Qualified by VESA  

Dossier de presse 2008-06-02

 
Exploring The Test Requirements For DisplayPort Receivers 
Exploring The Test Requirements For DisplayPort Receivers

Article 2008-01-28

PDF PDF 543 Bytes
Agilent Technologies Improves Industry's First DisplayPort Source Compliance, Characterization Test 

Dossier de presse 2007-12-05

 
Method of Implementation (MOI) for DisplayPort - Application Note 
Agilent Method of Implementation (MOI) for DisplayPort Sink Compliance Tests

Notes d’application 2007-11-03

PDF PDF 1.99 MB
Probe loading 
Probe loading

Démonstration de base 2005-12-22

WMF WMF 19.66 MB
Flexibility of Agilent's InfiniiMax Probe System 
This 10-minute video provides some very practical

Visite de produits 2004-11-22

WMF WMF 20.29 MB