89600 VSA Supported Hardware Platforms

Option 300 supports more than 30 hardware platforms. The table below provides additional information.

Signal and Spectrum Analyzers
Product Frequency Range Maximum Analysis Bandwidth Capture Depth Required Software  Instrument Requirements
X-Series Signal Analyzers
N9030A PXA 3 Hz to 50 GHz 160 MHz Up to 536 MSa X-Series Compatibility Matrix
N9020A MXA 10 Hz to 26.5 GHz 160 MHz Up to 536 MSa X-Series Compatibility Matrix
N9010A EXA 10 Hz to 44 GHz 25 MHz Up to 536 MSa X-Series Compatibility Matrix
N9000A CXA 9 kHz to 26.5 GHz 25 MHz 4 MSa X-Series Compatibility Matrix
N9038A MXE 20 Hz to 26.5 GHz 25 MHz 4 MSa X-Series Compatibility Matrix
PSA Series Spectrum Analyzers
E4440A, E4443A, E4445A, E4446A, E4447A, E4448A 3 Hz to 50 GHz 10 MHz Up to 900 kSa 89601B-300 Option B7J
Firmware Version ≥A.08 
E4440A, E4443A, E4445A, E4446A, E4448A 3 Hz to 50 GHz 40 MHz Up to 128 MSa 89601B-300  Option 140
Firmware Version ≥A.08
E4440A, E4443A, E4445A, E4446A, E4448A 3 Hz to 50 GHz 80 MHz Up to 128 MSa 89601B-300 Option 122
Firmware Version ≥A.08
ESA-E Series Spectrum Analyzers
E4402B, E4404B, E4405B, E4407B 9 kHz to 26.5 GHz 10 MHz 124 kSa 89601B-300  
Modular Products
M9391A PXI Vector Signal Analyzer 1 MHz to 6 GHz Up to 160 MHz 1 GSa

89601B-300 Version ≥17.20

 Software Version ≥1.1.300.0
M9392A PXI Vector Signal Analyzer 50 MHz to 26.5 GHz 40 or 250 MHz 128 MSa 

89601B-300
Version ≥15.00

Software Version ≥1.3.0.22
M9393A PXI Vector Signal Analyzer 9 kHz to 27 GHz Up to 160 MHz 1 GSa 89601B-300 Version ≥17.21  
M9703A AXIe Digitizer DC to 1.6 GHz 1 GHz Up to 1 GSa / ch 89601B-300 
Version ≥17.00 
Software Version ≥1.13.7.0
Windows 7: 64-bit only
Vector Signal Analyzers
89610A DC to 39 MHz 39 MHz 48 to 384 MSa 89601B-300
32-bit application only
 
89611A 52 to 88 MHz 36 MHz 48 to 384 MSa 89601B-300
32-bit application only
 
89640A DC to 2.7 GHz 36 MHz  48 to 384 MSa 89601B-300
32-bit application only
 
89641A DC to 6 GHz  36 MHz 48 to 384 MSa 89601B-300
32-bit application only
 
Oscilloscopes
 Product  Frequency Range  Maximum Analysis Bandwidth  Capture Depth  Required Software  Instrument Requirements
InfiniiVision
DSO:
6014L, 6054L, 6104L
InfiniiVision Application Note 512 kSa to 8 MSa 89601B-300 Software Version ≥4.01
DSO or MSO:
6012A, 6014A, 6032A, 6034A, 6052A, 6054A, 6102A, 6104A
InfiniiVision Application Note 512 kSa to 8 MSa 89601B-300 Software Version ≥2.02
DSO or MSO:
7012A, 7014A, 7032A, 7052A, 7102A, 7034A, 7054A, 7104A
InfiniiVision Application Note 2 to 8 MSa 89601B-300 Software Version ≥5.10
DSO or MSO:
7012B, 7032B, 7052B, 7014B, 7034B, 7054B, 7104B
InfiniiVision Application Note 2 to 8 MSa 89601B-300  
DSOX or MSOX:
3012A, 3014A, 3024A, 3032A, 3034A, 3052A, 3054A
InfiniiVision Application Note 2 to 4 MSa 89601B-300
Version ≥15.00
Software Version ≥4.30
DSOX or MSOX:
3102A, 3104A
InfiniiVision Application Note 2 to 4 MSa 89601B-300
Version ≥15.01
 
DSOX or MSOX:
4022A, 4024A, 4032A, 4034A, 4052A, 4054A, 4104A, 4154A
InfiniiVision Application Note 4 MSa 89601B-300
Version ≥16.00
 
Infiniium        
DSO or MSO:
S054, S104A, S204A, S254A, S404A, S604A, S804A
 Infiniium Application Note Up to 500 MSa 89601B-300
Version ≥18.00
 
DSO:
80204B, 80304B, 80404B, 80604B, 80804B, 81004B, 81204B, 81304B
Infiniium Application Note 512 kSa to 64 MSa 89601B-300  
DSO:
80804A, 81004A, 81204A, 81304A
Infiniium Application Note 512 kSa to 64 MSa 89601B-300 Software Version ≥4.01
DSO or DSA:
91304A, 91204A, 90804A, 90604A, 90404A, 90254A
Infiniium Application Note Up to 500 MSa 89601B-300 Software Versions
1.20.0000 to 3.06.0004
OR ≥3.23.0003
DSO or MSO:
8064A
Infiniium Application Note 2 to 64 MSa 89601B-300
Version ≥14.00
 
DSO or MSO:
8104A
Infiniium Application Note 2 to 64 MSa 89601B-300  
DSO or MSO:
9024H, 9054H, 9104H, 9204H
Infiniium Application Note 10 to 500 MSa 89601B-300
Version ≥16.20
 

DSO or MSO:
9064A, 9104A, 9254A, 9404A

Infiniium Application Note 10 to 500 MSa 89601B-300 Software Versions
1.20.0000 to 3.06.0004
OR ≥3.23.0003
DSOX or DSAX:
91304A
Infiniium Application Note 10 to 500 MSa 89601B-300
Version ≥16.20
Software Versions
3.00.0000 to 3.06.0004
OR ≥3.23.0003
DSOX or DSAX:
91604A, 92004A, 92504A, 92804A, 93204A
Infiniium Application Note 10 to 500 MSa 89601B-300
 
Software Versions
3.00.0000 to 3.06.0004
OR ≥3.23.0003
DSOX or DSAX:
93304Q, 92504Q, 92004Q
Infiniium Application Note 10 to 500 MSa 89601B-300
Version ≥15.01
 
DSOX or DSAX:
96204Q, 95004Q
Infiniium Application Note 10 to 500 MSa 89601B-300
Version ≥16.01
Software Version ≥4.30

MSOX:

91604A, 92004A, 92504A, 92804A, 93204A

Infiniium Application Note 10 to 500 MSa 89601B-300
Version ≥17.00
Software Versions
3.00.0000 to 3.06.0004
OR ≥3.23.0003
Logic Analyzers
 Product  Timing Rate  State Clock  Capture Depth Required Software Instrument Requirements 
1680 Series Standalone Logic Analyzers 800 MHz  200 MHz Up to 4 MB 89601B-300
32-bit application only
 
1690 Series PC-Hosted Logic Analyzers 800 MHz  200 MHz Up to 4 MB 89601B-300
32-bit application only
 
16800 Series Portable Logic Analyzers 500 MHz to 4 GHz  250 to 450 MHz Up to 32 MB 89601B-300
32-bit application only 
 
16900 Series Modular Logic Analyzer Systems 800 MHz to 4 GHz  200 MHz to 1.5 GHz Up to 256 MB  89601B-300
32-bit application only
 
N5343A/N5344A RDX Systems Not applicable Not applicable Not applicable 89601B-300
32-bit application only
Software Version ≥1.91
Other Platforms
 Product  Frequency Range  Maximum Analysis Bandwidth  Capture Depth  Required Software  Instrument Requirements
N7109A Multi-Channel Signal Analysis System 20 MHz to 6 GHz  40 MHz  132 MSa

89601B-300
Version ≥15.00

 
N4010A Wireless Connectivity Test Set 2.38 to 2.52 GHz and 4.8 to 5.88 GHz 40 MHz   500 kSa 89601B-300 Option 110
N6841A RF Sensor 20 MHz to 6 GHz  20 MHz  512 MB 89601B-300
Version ≥15.00