What hardware platforms are supported by the 89600 VSA and 89600 WLA Software?
On this page, you will find a listing of the different measurement hardware front ends for the current version of 89600 VSA and 89600 WLA software. You will find the model numbers supported, requirements needed and the specifications of each setup. Information can be found in these tables:
- 89600 VSA and 89600 WLA Software Supported Analog Measurement Hardware Front-ends
- 89600 VSA and 89600 WLA Software Supported Oscilloscopes
- 89600 VSA and 89600 WLA Software Supported Digital Measurement Hardware Front-ends
| Product/Model | 89601B Requirements | Hardware Requirements | Frequency Range | Bandwidth | Capture Depth |
|---|---|---|---|---|---|
| 89600 Series Vector Signal Analyzers | See Below | See Below | 36 - 39 MHz | 48 - 384 Msa | |
| 89610A |
89601B-300 |
DC - 39 MHz | 39 MHz | 48 - 384 Msa | |
| 89611A |
89601B-300 |
52 - 88 MHz | 36 MHz | 48 - 384 Msa | |
| 89640A |
89601B-300 |
DC - 2.7 GHz | 36 MHz | 48 - 384 Msa | |
| 89641A |
89601B-300 |
DC - 6 GHz | 36 MHz | 48 - 384 Msa | |
| ESA-E Series Portable Spectrum Analyzers | See Below | See Below | 9 kHz - 26.5 GHz | 10 MHz | 124 ksa |
| E4402B, E4404B, E4405B, E4407B | 89601B-300 | ESA Options: 229, 231, B7D, B7E, 1D5, A4H, B72 Firmware version A.08.04 or greater. Option 229 version A.02.01 or greater. Option 231 version A.02.00 or greater | Model Dependant | 10 MHz | 124 ksa |
| PSA Series Spectrum Analyzer | See Below | See Below | 3 Hz - 50 GHz | 8 - 80 MHz | 900 ksa - 128 Msa |
| E4440A, E4443A, E4445A, E4446A, E4447A, E4448A | 89601B-300 | PSA Option B7J Firmware version A.08 or greater | Model Dependant | 8 MHz | 900 ksa |
| E4440A, E4443A, E4445A | 89601B-300 | PSA Option 140 Firmware version A.08 or greater | Model Dependant | 40 MHz | 128 Msa |
| E4440A, E4443A, E4445A | 89601B-300 | PSA Option 122 Firmware version A.08 or greater | Model Dependant | 80 MHz | 128 Msa |
| N4010A Wireless Connectivity Test Set | See Below | See Below | See Below | 40 MHz | 500 ksa |
| N4010A | 89601B-300 | N4010A-110 | 2.38 - 2.52 GHz and 4.8 - 5.88 GHz | 40 MHz | 500 ksa |
| X-Series Signal Analyzer | See Below | See Below | See Below | 10 - 140 MHz | 4 - 500 Msa |
| N9038A - MXE | Refer to compatability matrix | Refer to compatability matrix | Option Dependant | Option Dependant | Option Dependant |
| N9030A - PXA | Refer to compatability matrix | Refer to compatability matrix | Option Dependant | Option Dependant | 500 Msa |
| N9020A - MXA | Refer to compatability matrix | Refer to compatability matrix | Option Dependant | Option Dependant |
Option Dependant |
| N9010A - EXA | Refer to compatability matrix | Refer to compatability matrix | Option Dependant | Option Dependant | 4 Msa |
| N9000A - CXA | Refer to compatability matrix | Refer to compatability matrix | Option Dependant | Option Dependant | 4 Msa |
| N7100 Multi-channel Signal Analysis System | See Below | See Below | 20 MHz - 6 GHz | 40 MHz | 132 Msa |
| N7109A | 89601B-300 | 20 MHz - 6 GHz | 40 MHz | 132 Msa | |
| Modular Instruments | See Below | See Below | Model Dependant | Model Dependant | Model Dependant |
|
M9392A |
89601B-300 |
Software version 1.3.0.22 or greater | 50 MHz -26.5 GHz | 40 or 250 MHz | 128 Msa |
|
M9703A |
89601B-300 |
Software version 1.11.2.0 or greater |
Option Dependant | Option Dependant | Option Dependant |
| RF Sensor | |||||
| N6841A |
89601B-300 |
20 MHz - 6 GHz | 20 MHz | 512 MB |
| Product/Model | 89601B Requirements | Hardware Requirements | Frequency Range | Bandwidth | Capture Depth |
|---|---|---|---|---|---|
| (DSO or MSO): 9024H, 9054H, 9104H, 9204H |
89601B-300 Version 16.20 or greater |
Model Dependant | Model Dependant | 10 MSa - 500 MSa | |
| (DSOX or MSOX): 4022A, 4024A, 4032A, 4034A, 4052A, 4054A, 4104A, 4154A |
89601B-300 |
Model Dependant | Model Dependant | 4 Msa | |
| (DSOX or MSOX): 3102A, 3104A |
89601B-300 |
Model Dependant | Model Dependant | 2 - 4 MSa | |
| (DSOX or DSAX): 96204Q, 95004Q |
89601B-300 Version 16.01 or greater |
Software version 4.30 or greater | Model Dependant | Model Dependant | 10 MSa - 500 MSa |
| (DSOX or DSAX): 93304Q, 92504Q, 92004Q |
89601B-300 |
Software version 4.00 or greater | Model Dependant | Model Dependant | 10 MSa - 500 MSa |
| (DSOX or MSOX): 3012A, 3014A, 3024A, 3032A, 3034A, 3052A, 3054A |
89601B-300 |
Model Dependant | Model Dependant | 2 - 4 MSa | |
| (DSOX or DSAX): 91604A, 92004A, 92504A, 92804A, 93204A | 89601B-300 |
Software versions |
Model Dependant | Model Dependant | 10 MSa - 500 MSa |
| (DSOX or DSAX): 91304A |
89610B-300 Version 16.20 or greater |
Software versions 3.00.0000 - 3.06.0004 OR 3.23.0003 or greater |
Model Dependant | Model Dependant | 10 MSa - 500 MSa |
| (DSO): 91304A, 91204A, 90804A, 90604A, 90404A, 90254A | 89601B-300 |
Software versions |
Model Dependant | Model Dependant | Up to 500 MSa |
| (DSO or MSO) 9064A, 9104A, 9254A, 9404A | 89601B-300 |
Software versions |
Model Dependant | Model Dependant | 10 MSa - 500 MSa |
| (DSO or MSO): 7012A, 7014A, 7032A, 7052A, 7102A, 7034A, 7054A, 7104A | 89601B-300 | Software version 5.10 or greater | Model Dependant | Model Dependant | 2 MSa - 4 MSa |
| (DSO or MSO): 7012B, 7032B, 7052B, 7014B, 7034B, 7054B, 7104B | 89601B-300 | Model Dependant | Model Dependant | 2 MSa - 4 MSa | |
| (DSO or MSO): 6012A, 6014A, 6032A, 6034A, 6052A, 6054A, 6102A, 6104A | 89601B-300 | Software version 2.02 or greater | Model Dependant | Model Dependant | 512 ksa - 4 Msa |
| DSO6014L, DSO6054L, DSO6104L | 89601B-300 | Software version 4.01 or greater | Model Dependant | Model Dependant | 512 ksa - 4 Msa |
| DSO: 80804A, 81004A, 81204A, 81304A | 89601B-300 | Software version 4.01 or greater | Model Dependant | Model Dependant | 512 ksa - 64 Msa |
| (DSO or MSO):8064A |
89601B-300 |
Model Dependant | Model Dependant | 2 - 64 Msa | |
| (DSO or MSO): 8104A | 89601B-300 | Model Dependant | Model Dependant | 2 - 64 Msa | |
| DSO: 80204B, 80304B, 80404B, 80604B, 80804B, 81004B, 81204B, 81304B | 89601B-300 | Model Dependant | Model Dependant | 512 ksa - 64 Msa |
| Product / Model | Additional Requirements | Hardware Requirements | Timing Rate | State Clock | Memory Depth |
|---|---|---|---|---|---|
| 1680 Series Standalone Logic Analyzers |
89601B-300 |
800 MHz | 200 MHz | 1-4 MB | |
| 1690 Series PC-Hosted Logic |
89601B-300 |
800 MHz | 200 MHz | 1-4 MB | |
| 16800 Series Portable Logic Analyzers |
89601B-300 |
500 MHz - 4 GHz | 250 - 450 MHz | 1-32 MB | |
| 16900 Series Modular Logic Analysis Systems |
89601B-300 |
800 MHz - 4 GHz | 200 MHz - 1.5 GHz | 1-128 MB | |
| N5343A / N5344A RDX Systems |
89601B-300 |
Software version 1.91 or greater |