Which AXIe modules can be controlled using the USB option on the AXIe chassis ESM (M9502A-U20 and M9505A-U20)?
The only modules supported through USB connectivity to a host PC are the following Agilent logic and protocol analyzer modules.
FAQ 2013-01-09 |
|
|
Do I need to perform a periodic front panel instrument alignment on my N9039A RF Preselector?
No, but there is a system alignment that needs to be periodically run. See FAQ content for details...
FAQ 2012-12-11 |
|
|
How often does the system user alignment for the PSA EMI Measurement Receiver need to be run?
30 days or 3° C temperature change. See contents for details...
FAQ 2012-12-11 |
|
|
What is the process to capture a trace image to the floppy disk on the Agilent 8712ES/ET and 8714ES/ET Vector Network Analyzers?
The 8712ES/ET and 8714ES/ET Vector Network Analyzers support HPGL, PCX, PCL5, and GIF image saves via the floppy drive.
FAQ 2012-12-11 |
|
|
What Configuration issues are there with option AYQ, Quasi Peak Detector in the ESA-E Series of Spectrum Analyzers?
View the compatibility issues here....
FAQ 2012-12-05 |
|
|
Are there any reference documents for TRL Calibration of network analyzers?
FAQ 2012-11-05 |
|
|
Is it possible to programmatically receive the displayed low/high stimulus values when using the “CALC1:MARK:BWID:DATA?” bandwidth query results?
When manually configuring the ENA network analyzer via the Marker – Marker Search – Bandwidth ON, the manual process results in low and high stimulus values as displayed on the analyzer’s front panel.
FAQ 2012-10-31 |
|
|
What external mixers will work with my PXA/mmW EXA and how do I order them?
Currently, the N9030A PXA/mmW EXA with Option EXM will work with either the 11970 Series (with the exception of the 11970K) or ) or external mixers from other vendors such a OML Inc. mixers.
FAQ 2012-10-17 |
|
|
Is it possible on the Agilent ENA series Network Analyzers to over-ride the output source blanking at every sweep end?
Yes, the output source blanking on sweep retrace can be prevented by turning off the Initial Source Port Control function.
FAQ 2012-10-17 |
|
|
Can I use a USB memory to update the firmware for the ENA?
It depends on the model.
FAQ 2012-10-17 |
|
|
On the Agilent E4980A, what is the "DC Source Option 001 (±10 VDC Max)" and how is it utilized?
A summary description of the enhancements provided by E4980A option 001 - 'Power and DC Bias Enhancement Option'
FAQ 2012-10-15 |
|
|
Which Agilent oscilloscopes have a 10 MHz reference input/output?
6000 Series, 6000L Series, 7000A Series, 7000B Series, 9000 Series, 54850 Series (Output only), 80000A Series, 80000B Series, 90000A Series and 90000 X-Series
FAQ 2012-09-29 |
|
|
Can I manually set the sample rate on my InfiniiVision oscilloscope?
Although the sample rate cannot be directly set on any InfiniiVision oscilloscope, it can be set indirectly by adjusting the oscilloscopes time per division setting.
FAQ 2012-09-29 |
|
|
What is the difference between the Auto and Normal trigger modes on InfiniiVision oscilloscopes?
In auto trigger mode, the trigger will be forced if the specified conditions are not met. In normal trigger mode, the trigger will never be forced and a trigger will only occur if the specified conditions are met.
FAQ 2012-09-29 |
|
|
What features are different between the ENA 7 series and the ENA 6 series?
Followings are the difference between the ENA 7 series and the ENA 6 series.
FAQ 2012-09-25 |
|
|
On the ENA 6 series, can I use Supr Avoid ON/OFF function like the 871x?
No. It is always ON.
FAQ 2012-09-25 |
|
|
What is the difference between the ENA 6 series opt.100 (fault location) and the ENA opt.010 (time domain)?
Both options are aim to do time domain conversion. The ENA 6 series opt.100 focuses on to analyze the cable characteristics...
FAQ 2012-09-25 |
|
|
Are mixed mode S-parameter measurements possible on the 2-port ENA?
Yes. The equation editor function allows for the real-time calculation of mixed mode S-parameters on the 2-port ENA.
FAQ 2012-09-25 |
|
|
Does the ENA 6 series support direct sampler measurements and user ratio measurements?
No.
FAQ 2012-09-25 |
|
|
On the ENA 6 series, can I use swept sweep mode?
No. The ENA 6 series always sweeps in step.
FAQ 2012-09-25 |
|
|
How do I get >8 bit vertical resolution on my Agilent real-time oscilloscope?
Most Agilent oscilloscopes give 8-bit vertical resolution at normal acquisition mode.
FAQ 2012-08-31 |
|
|
How to calculate the bit clock frequency under DSI interface of U8903A?
The Bit clock frequency can be calculated by multipling the number of channels,bit length and frame clock frequency.
FAQ 2012-08-25 |
|
|
Can I use an Agilent 85032E Cal Kit with FieldFox instruments?
Yes. You can use an 85032E Cal kit with FieldFox.
FAQ 2012-08-20 |
|
|
Is it possible to modify the scale on the return loss plot when the measurement is configured for Return Loss & DTF on a FieldFox instrument?
There is no method to change the scale on the upper Return Loss (top) plot.
FAQ 2012-08-20 |
|
|
Will FieldFox instruments be able to differentiate between internal and external zeroing when using the U200xA/B/H USB power sensors?
FieldFox instruments cannot do this differentiation, but FieldFox allows you the choice of external zeroing.
FAQ 2012-08-20 |
|