Will there be specification, performance characteristic or usability differences when using the 11970 Series mixers on the PXA?
Yes, there will be several differences when using 11970 Series mixers with the
FAQ 2013-04-26 |
|
|
Will the PXA work with the N8975AZ-Kxx block down converters for noise figure to 110 GHz?
...will...to...N8975AZ-Kxx...noise...figure...block...converters...with...PXA
FAQ 2013-04-26 |
|
|
ENA 6 시리즈는 주파수 스윕할 때 swept sweep 모드를 지원합니까?
아니요..
FAQ 2013-04-25 |
|
|
외부 믹서 연결 옵션 EXM은 11974 시리즈 Preselected Mixer를 지원할 예정입니까?
아니요.
FAQ 2012-10-25 |
|
|
Is it possible on the Agilent ENA series Network Analyzers to over-ride the output source blanking at every sweep end?
Yes, the output source blanking on sweep retrace can be prevented by turning off the Initial Source Port Control function.
FAQ 2012-10-17 |
|
|
Are there any step-by-step measurement examples for ENA 7 series?
Yes. There are some measurement examples in ENA help file...
FAQ 2012-10-17 |
|
|
What is the difference between an "ECal Confidence Check" and a Network Analyzer "System Verification" test?
The ECal Confidence Check is a method to check the accuracy of a calibration performed with either a mechanical cal kit or an ECal module. System verification testing provides network analyzer users a method to verify that the network analyzer is ...
FAQ 2012-10-17 |
|
|
On the Agilent E4980A, what is the "DC Source Option 001 (±10 VDC Max)" and how is it utilized?
A summary description of the enhancements provided by E4980A option 001 - 'Power and DC Bias Enhancement Option'
FAQ 2012-10-15 |
|
|
Which Agilent oscilloscopes have a 10 MHz reference input/output?
6000 Series, 6000L Series, 7000A Series, 7000B Series, 9000 Series, 54850 Series (Output only), 80000A Series, 80000B Series, 90000A Series and 90000 X-Series
FAQ 2012-09-29 |
|
|
What is the difference between the Auto and Normal trigger modes on InfiniiVision oscilloscopes?
In auto trigger mode, the trigger will be forced if the specified conditions are not met. In normal trigger mode, the trigger will never be forced and a trigger will only occur if the specified conditions are met.
FAQ 2012-09-29 |
|
|
Can I manually set the sample rate on my InfiniiVision oscilloscope?
Although the sample rate cannot be directly set on any InfiniiVision oscilloscope, it can be set indirectly by adjusting the oscilloscopes time per division setting.
FAQ 2012-09-29 |
|
|
Can I make absolute measurements on the ENA?
Yes.
FAQ 2012-09-25 |
|
|
How to calculate the bit clock frequency under DSI interface of U8903A?
The Bit clock frequency can be calculated by multipling the number of channels,bit length and frame clock frequency.
FAQ 2012-08-25 |
|
|
How can I de-embed a test fixture using the 86100C/D Digital Communications Analyzer?
N1010A software with InfiniiSIM-DCA option provides the capability to de-embed and embed fixtures, cables, probes, and other circuit elements.
FAQ 2012-08-06 |
|
|
U1251B, U1252B, U1253B 휴대용 멀티미터에서 측정 간격을 설정 할 수 있나요?
네, 설정이 가능 합니다.
FAQ 2012-07-31 |
|
|
N9082A또는 89601X-BHE를 PUSCH와 PUCCH의 multi-user 변조분석에 사용 할 수 있습니까?
네, N9082A와 89601X-BHE는 한 번에 multi-user신호들을 검출할 수 있습니다.
FAQ 2012-07-30 |
|
|
What is the maximum bit clock cycle per frame for DSI interface of U8903A?
64 bit clock cycle per frame.
FAQ 2012-07-25 |
|
|
Does the E4406A or PSA Series Spectrum Analyzer provide GSM trigger to time zero (T0) timing in order to test Enhanced Observed Time Difference Tec...
Yes, the EDGE / GSM measurement personalities for the E4406A and PSA Series provide precise nanosecond timing between an external trigger and the training sequency T0 transition point. (click here for more details).
FAQ 2012-05-28 |
|
|
Does the E4406A or PSA Series support GPRS measurements?
Both the E4406A and PSA Series support GPRS measurements. For the E4406A, option BAH (GSM) or option 202 (EDGE with GSM) are required. For the PSA, option 202 (GSM with EDGE) and option B7J (Digital Demodulation hardware) are required.
FAQ 2012-05-28 |
|
|
How do I perform WCDMA Power Control measurements on the E4406A or PSA Series Spectrum Analyzers?
Reverse link power control measurements can be made using the W-CDMA (Option BAF) power control measurement. Power control analysis on the downlink can be done in the Code Domain Power measurement using the Symbol Power vs. Time view.
FAQ 2012-05-28 |
|
|
How do I make the signal list compare measurements made with the detectors used to different limit lines in my MXE EMI Receiver?
Meas Setup, Detectors (Measure)...
FAQ 2012-05-10 |
|
|
How do a take a sweep with both the Quasi-Peak and EMI Average detector at the same time with an MXE EMI Receiver?
Switch to EMI Receiver mode...
FAQ 2012-05-10 |
|
|
Why do I get a Meas Uncal message when I select either the Quasi-Peak or EMI Average detector for taking a full band sweep with the MXE EMI Receiver?
Sweeptime has reached its maximum. See complete FAQ for further details...
FAQ 2012-05-10 |
|
|
Can I use the Fixture Simulator functions with the 2-port ENA?
Yes, but the function is limited...
FAQ 2012-03-16 |
|
|
Can I order a 3.5 mm connector for 26 GHz and below PXAs? Will the 3.5 mm connector be available on the 40/50 GHz units?
3.5 mm connector (Option C35) is orderable on the 26.5 GHz N9030A PXA (Option 526 only) starting in April 2011. The 43, 44 and 50 GHz N9030A PXAs (options 543, 544, 550) have 2.4 mm connectors.
FAQ 2012-03-02 |
|