What is the best way to measure PDL (Mueller matrix 8169A, 11896A) (speed, accuracy)?
There are several different ways to characterize polarization dependent loss (PDL) on a device.

FAQ 2011-07-06

What accessories should I order with the 816XX Tunable Laser Sources?
See long answer.

FAQ 2011-07-06

What is the correct filter size for the 81000FA filter holder?
The 81000FA is an accessory which mounts on to an 8152x or 8162x optical head. The dimensions ...

FAQ 2011-07-06

What is the minimum attenuation step on the 8156A?
The 8156A has an attenuation range of 60 dB with a minimum step size of 0.001 dB.

FAQ 2011-07-06

What is the difference between the 8100xxA connector adapter and the 81000xI connector interface?
The 8100xxA series adapters are for use with optical heads.

FAQ 2011-07-06

Can I connect angled to flat or straight or visa versa?
No, generally neither connection of different connector types (straight vs. angled) can be done.

FAQ 2011-07-06

How can I read the responsivity data of my 8163x optical power sensor module, optical head, and ...
To read out the responsivity data of your optical power sensor module, optical head or attenuator ...

FAQ 2011-07-06

What accessories should I order with the 8166XA DFB Laser?
An 816x mainframe is required to operate a DFB Laser Source Module. Additionally, a connector adapter ...

FAQ 2011-07-06

How can I mount an optical head in an instrumentation rack?
To mount two (2) 8162x optical heads side by side next to an 8163A optical multimeter, please order ...

FAQ 2011-07-06

How do I calibrate the 81534A Return Loss Module with the 81610CC Reference Cable?
A patchcord between the output of Return Loss Module and 81610CC reference cable has to be used..

FAQ 2011-07-06

Can the output power on the 8166xA DFB source be adjusted?
The maximum output power on the sources can be attenuated up to 6.0 dB, in 0.1 dB steps.

FAQ 2011-07-06

What is the calibration cycle for the 8163x / 8153x power sensor modules?
The calibration cycle for the newer optical sensors (8163x) is 24 months.

FAQ 2011-07-06

Can I adjust the large slot laser sweep rate using the internal PACT application for the 8164 mainframe?
The sweep rate is not directly settable. It is currently defaulted to 5 nm/sec.

FAQ 2011-07-06

Can I use the 81611/12/13/14A as a Fabry-Perot source for an insertion loss measurement?
Yes, the 81611/12/13/14A each have an internal Fabry-Perot source.

FAQ 2011-07-06

Can I use multimode fiber on a single mode output and vice versa?
Apart from any loss resulting from Fresnel-reflections on the concatenation of the two fibers ...

FAQ 2011-07-06

Do the 8166xA DFB Laser Sources have optical isolators on the output?
Each 8166xA DFB Laser Source has an optical isolator on the output.

FAQ 2011-07-06

Can I get a dual channel optical power sensor module with an analog output?
There is no room on the dual channel power sensor for an analog output.

FAQ 2011-07-06

Are all of the TLSs shipped standard with an optical attenuator on the output?
The 81480A/81640A/80A all have a 60dB attenuator, 0.001 dB steps.

FAQ 2011-07-06

What is the difference between the 8163xA and the 8163xB power sensors?
The 8163xA optical power sensors did not have an analog output available.

FAQ 2011-07-06

What is the difference between the optical inputs on the different 8163x optical power sensor modules?
The 81632x/ 81635x have straight fiber on the input. The 1633x/81634x have a recessed lens on the input.

FAQ 2011-07-06

Does Agilent have a recommended solution for inspecting the output ferrules?
Agilent does not offer a visual ferrule inspection tool as part of its' product line.

FAQ 2011-07-06

Why can't I acquire the license key?
To rely on the CPU- ID remove the network-card before installing the PFL.

FAQ 2011-07-05

Can I use the 815xx Modules with the newer 816x mainframes? What are the trade-offs?
The 815xx modules will operate in the 8163 and 8164 mainframe, but NOT in the 8166 mainframe.

FAQ 2011-07-05

What is the rack mount kit for the 8169A polarization controller?
Below is a list of rack mount part numbers for the 8169A. Note that the 8169A is a full width mainframe.

FAQ 2011-07-05

What is the calibration cycle for the interface modules?
The 81618A/81619A interface modules do not require calibration.

FAQ 2011-07-05