What is the rack mount kit for the 8169A polarization controller?
Below is a list of rack mount part numbers for the 8169A. Note that the 8169A is a full width mainframe.

FAQ 2011-07-05

What is the difference between the FETCH and the READ command to get the data from the power modules?
The FETCH and READ command will both acquire a power reading from the mainframe.

FAQ 2011-07-05

Can I use the 816xx series modules in any of the 816x mainframes?
The compact modules will operate in any of the 816X mainframes. However, the large slot tunable ...

FAQ 2011-07-05

Why can't I acquire the license key?
To rely on the CPU- ID remove the network-card before installing the PFL.

FAQ 2011-07-05

How do I make high power measurements with an optical head?
The + 27 dBm optical heads are convenient for high-power measurements.

FAQ 2011-07-05

What happens if the power unit is changed from dBm to Watt or vice versa?
All dependent parameters are automatically converted accordingly so all features remain fully functional.

FAQ 2011-07-05

How much hysteresis does the power control loop of the 81566A/67A show?
There are two threshold levels (if power control is active).

FAQ 2011-07-05

What is the calibration cycle for the 816x mainframes?
The 816x mainframes do not require calibration.

FAQ 2011-07-05

What is the difference between the 8162xA and the 8162xB optical heads?
The main difference is the 8162xB models (except the 81625B) offer an analog output, the 8162xA's do not.

FAQ 2011-07-05

Should I use a Germanium (Ge) or a Indium Gallium Arsenide (InGaAs) optical head?
An important difference between Ge and InGaAs is the shape of the spectral responsivity curves.

FAQ 2011-07-05

Does Agilent Technologies offer analog outputs for the optical heads?
Agilent Technologies offers several different optical heads:

FAQ 2011-07-05

Is the 8156xA suitable for Cable TV applications?
The angled connector versions 81561A and 81567A avoid irritating interference effects.

FAQ 2011-07-05

Can I use the 815xx Modules with the newer 816x mainframes? What are the trade-offs?
The 815xx modules will operate in the 8163 and 8164 mainframe, but NOT in the 8166 mainframe.

FAQ 2011-07-05

How is the 8169A different from the 11896A polarization controller?
The 8169A Provides polarization synthesis relative to a built-in linear polarizer.

FAQ 2011-07-05

I just received my new 816x module and the mainframe does not recognize the module. What should I do?
The mainframe firmware must be at least the same revision number as the module.

FAQ 2011-07-05

How small is CD and PMD of the 8156xA?
The value of CD and PMD of the 8156xA is equivalent to the value of about 1 m optical fiber SMF28.

FAQ 2011-07-05

Is the power control loop of the 81566A/67A also working for signal packets?
Yes, the averaging time of the 81566A/67A has to be adjusted to a time significantly longer than ...

FAQ 2011-07-05

What kind of power sensor is used in the 81566A/67A?
The 81566A/67A uses an InGaAs photodiode, similar to Agilent's 81632A power sensor module.

FAQ 2011-07-05

How do I interpret the binary data which is retrieved over the GPIB from the Stability/Logging application?
The data has the following format ...

FAQ 2011-07-05

Why should I use an optical head for optical power measurements?
Use heads for bare fiber, open beam, highly accurate absolute power or high power measurements.

FAQ 2011-07-05

When I calibrate power/ return loss / source modules, do I send the mainframe as well?
No, it is not required to send in a mainframe to calibrate individual modules.

FAQ 2011-07-05

What is the calibration cycle for the 8161x Optical Return Loss Module?
The 8161X Optical Return Loss Modules have a 24 month calibration cycle.

FAQ 2011-07-05

When upgrading my 816xB mainframe using ATTools, my computer reports "Cannot initialize serial port ...
A background task, such as hot synchronization, may be using the serial port.

FAQ 2011-07-05

How large is the optical head detector area?
All optical heads from Agilent Technologies use large area detectors.

FAQ 2011-07-05

Why would I want to use the analog output on the front of the optical head?
The analog output provides a voltage (0-2V) proportional to the optical power in a given range ...

FAQ 2011-07-05