Hable con un experto

Soporte Técnico

Medición Electrónica

Buscar Producto por No. de Modelo: Ejemplos: 34401A y E4440A

76-100 de 379

Ordenar:
What accessories should I order with the 8165XA FP Laser?
An 816x mainframe is required to operate a FP Laser. Additionally, a connector adapter ...

FAQ 2011-07-06

What is the best way to measure PDL (Mueller matrix 8169A, 11896A) (speed, accuracy)?
There are several different ways to characterize polarization dependent loss (PDL) on a device.

FAQ 2011-07-06

What accessories should I order with the 8166XA DFB Laser?
An 816x mainframe is required to operate a DFB Laser Source Module. Additionally, a connector adapter ...

FAQ 2011-07-06

My 816xx large slot or compact tunable laser is displaying "Laser Safety Error". What does this mean?
The Realign procedure should be run on the laser to see if it will clear the problem.

FAQ 2011-07-06

Can I use the 81611/12/13/14A as a Fabry-Perot source for an insertion loss measurement?
Yes, the 81611/12/13/14A each have an internal Fabry-Perot source.

FAQ 2011-07-06

What is the correct filter size for the 81000FA filter holder?
The 81000FA is an accessory which mounts on to an 8152x or 8162x optical head. The dimensions ...

FAQ 2011-07-06

What is the model number for the magnetic D ring on the front of the 8162x optical head?
The magnetic D-ring model number is 81624DD.

FAQ 2011-07-06

How is a computer's fingerprint ID obtained?
To rely on the CPU- ID remove the network-card before installing the PFL.

FAQ 2011-07-06

Why won't my High Power 8165xA FP laser source turn on?
When the 8164A is first turned on it requests a password.

FAQ 2011-07-06

Does the 81689A operate with the Lambda Scan in the PNP Drivers?
No, Lambda Scan requires one of the large slot tunable lasers.

FAQ 2011-07-06

What is the monitor output option for the 8156A optical attenuator?
When the attenuator is ordered with the monitor output, a 13 dB coupler is placed after the attenuator ...

FAQ 2011-07-06

Can I use the 81000FB bare fiber adapter with laser sources?
No, the 81000FB is designed for adapting bare fibers to sensor modules only.

FAQ 2011-07-06

Are the inputs and outputs from the 8161xA return loss modules straight or angled?
The input and the output on the 8161xA return loss modules are angled connections.

FAQ 2011-07-06

Can I adjust the large slot laser sweep rate using the internal PACT application for the 8164 mainframe?
The sweep rate is not directly settable. It is currently defaulted to 5 nm/sec.

FAQ 2011-07-06

Can I use the 815xxA Series optical heads with the 81618A / 81619A interface modules?
The 815xxA Optical Heads can NOT be used with the 81618A/81619A interface modules.

FAQ 2011-07-06

Is the output for the 8165xA FP sources straight or angled?
The outputs of the 8165xA FP sources are all straight.

FAQ 2011-07-06

What accessories should I order with the 816XX Tunable Laser Sources?
See long answer.

FAQ 2011-07-06

What is the maximum safe input power for the 8156A optical attenuator?
The maximum safe input power for the 8156A attenuator is +23dBm (200mW).

FAQ 2011-07-06

How do I upgrade the firmware for large slot tunable lasers in the 8164 mainframe?
You can upgrade the 816xx full size tunable lasers firmware via GPIB, via floppy disks or ...

FAQ 2011-07-06

Are all of the TLSs shipped standard with an optical attenuator on the output?
The 81480A/81640A/80A all have a 60dB attenuator, 0.001 dB steps.

FAQ 2011-07-06

Can the output power on the 8165xA FP laser sources be adjusted?
The nominal maximum output power of these sources can be attenuated up to 6.0 dB.

FAQ 2011-07-06

Do the large slot and compact tunable laser sources have optical isolators on the output?
Yes, all of the TLS's have optical isolators on the output.

FAQ 2011-07-06

How can I read the responsivity data of my 8163x optical power sensor module, optical head, and ...
To read out the responsivity data of your optical power sensor module, optical head or attenuator ...

FAQ 2011-07-06

Why can't I install the license key from my PFL CD-ROM?
If you have PFL version 1.0.3 the installation process is described on the CD-ROM (PFL README.pdf).

FAQ 2011-07-05

Can I use the newer 816xx modules in the older 8153A mainframe?
The new 816xx modules will NOT operate in the older 8153A mainframe.

FAQ 2011-07-05