Sprechen Sie mit einem Experten
Technical Support
Test & Messtechnik
Refine the List
Alle detailierte Suchkriterien entfernen
Nach Oberbegriff
- Configuration & Installation (8)
- Display Messages/Error Codes (3)
- Measurement & Instrument Fundamentals (6)
- Measurement Techniques (11)
- Operating System & Software (9)
- Operation & Functionality (24)
- Other Information (1)
- Parts & Accessories (9)
- Product & Firmware Updates & Upgrades (6)
- Programming & Data Transfer (2)
- Service & Maintenance (6)
- Specifications & Accuracy (5)
- Troubleshooting (6)
Nach Applikation
By Type of Content
- FAQ (374)
Nach Produkt Kategorie
-
Alle Produkt Kategorien
-
Additional Test & Measurement Products
- Photonic Test & Measurement Products
-
Additional Test & Measurement Products
26-50 of 374
|
Are all of the TLSs shipped standard with an optical attenuator on the output?
The 81480A/81640A/80A all have a 60dB attenuator, 0.001 dB steps.
FAQ 2011-07-06 |
|
|
Can the output power on the 8165xA FP laser sources be adjusted?
The nominal maximum output power of these sources can be attenuated up to 6.0 dB.
FAQ 2011-07-06 |
|
|
What accessories should I order with the 8165XA FP Laser?
An 816x mainframe is required to operate a FP Laser. Additionally, a connector adapter ...
FAQ 2011-07-06 |
|
|
Can I adjust the large slot laser sweep rate using the internal PACT application for the 8164 mainframe?
The sweep rate is not directly settable. It is currently defaulted to 5 nm/sec.
FAQ 2011-07-06 |
|
|
What is the rack mount kit for the 8156A optical attenuator?
Below is a list of possible rack mount part numbers for the 8156A.
FAQ 2011-07-06 |
|
|
My 816xx large slot or compact tunable laser is displaying "Laser Safety Error". What does this mean?
The Realign procedure should be run on the laser to see if it will clear the problem.
FAQ 2011-07-06 |
|
|
Can the 81003FD (also valid for all the other 81003xx adapters) be used with the 8152xx optical heads?
No, the 81003FD will not work with the 8152xx series optical heads.
FAQ 2011-07-06 |
|
|
How can I operate the 8156A as a calibrated back reflector?
Accessories required are: 81000SI, 81113PC, 81000UM, 81000FI, 81000BR.
FAQ 2011-07-06 |
|
|
How can I read the responsivity data of my 8163x optical power sensor module, optical head, and ...
To read out the responsivity data of your optical power sensor module, optical head or attenuator ...
FAQ 2011-07-06 |
|
|
Do the 8165XA FP Laser Sources have optical isolators on the output?
Each 8165xA FP Laser Source has an optical isolator on the output.
FAQ 2011-07-06 |
|
|
Do you have any specifications and a picture of the 81618A, 81619A interface modules?
Agilent Technologies does not publish specifications for the 81618A/19A interface modules.
FAQ 2011-07-06 |
|
|
Can I use multimode fiber on a single mode output and vice versa?
Apart from any loss resulting from Fresnel-reflections on the concatenation of the two fibers ...
FAQ 2011-07-06 |
|
|
Can I connect angled to flat or straight or visa versa?
No, generally neither connection of different connector types (straight vs. angled) can be done.
FAQ 2011-07-06 |
|
|
Can the output power on the 8166xA DFB source be adjusted?
The maximum output power on the sources can be attenuated up to 6.0 dB, in 0.1 dB steps.
FAQ 2011-07-06 |
|
|
What is the maximum safe input power for the 8156A optical attenuator?
The maximum safe input power for the 8156A attenuator is +23dBm (200mW).
FAQ 2011-07-06 |
|
|
What accessories should I order with the 8161xA Optical Return Loss Modules?
The following accessories are recommended for use with the 8161xA Optical Return Loss Modules.
FAQ 2011-07-06 |
|
|
What is the input and output fiber type for the 8169A polarization controller?
The input and output fiber on the 8169A is standard single mode fiber.
FAQ 2011-07-06 |
|
|
Can I use the 81611/12/13/14A as a Fabry-Perot source for an insertion loss measurement?
Yes, the 81611/12/13/14A each have an internal Fabry-Perot source.
FAQ 2011-07-06 |
|
|
Why won't my High Power 8165xA FP laser source turn on?
When the 8164A is first turned on it requests a password.
FAQ 2011-07-06 |
|
|
Do the 8166xA DFB Laser Sources have optical isolators on the output?
Each 8166xA DFB Laser Source has an optical isolator on the output.
FAQ 2011-07-06 |
|
|
What is the difference between the optical inputs on the different 8163x optical power sensor modules?
The 81632x/ 81635x have straight fiber on the input. The 1633x/81634x have a recessed lens on the input.
FAQ 2011-07-06 |
|
|
What is the calibration cycle for the 8156A optical attenuator?
The recommended calibration cycle for the 8156A is 24 months.
FAQ 2011-07-06 |
|
|
What are the differences between 81640A/80A/42A/82A high performance vs. 81689A compact TLS?
There are a lot of differences between the larger TLS and the smaller one.
FAQ 2011-07-06 |
|
|
Does the 81689A operate with the Lambda Scan in the PNP Drivers?
No, Lambda Scan requires one of the large slot tunable lasers.
FAQ 2011-07-06 |
|
|
What accessories should I order with the 8166XA DFB Laser?
An 816x mainframe is required to operate a DFB Laser Source Module. Additionally, a connector adapter ...