FAQs:
RF & Microwave Test Accessories

Examinar FAQs

Idioma:Español | English | Ambos

Acotado por:

FAQs | RF & Microwave Test Accessories

1-25 de 95

Ordenar:

Resultados

Título/ descripción Fecha Tipo
8510: Annual Certification of Calibration Kit 2002-06-27 FAQ
8510: What Is the Difference between 2.4mm and 2.92 'K' Connectors? 2002-06-27 FAQ
8647A and 8648 Series RF Blanking 2002-06-27 FAQ
Are any of the L4491A mounting rails removable?
Yes, the L4491A mounting bays can be removed or a pre-drilled bottom plate is available by ordering option 006.
2008-04-04 FAQ
Are the 830xxA, 874xxA family of amplifiers DC-blocked on the input and/or output? If so, what is the maximum safe DC input voltage on both the input and output?
2004-02-18 FAQ
Are the N2276A and N2276B multiplexers compatible with the 3499B mainframe?
No, the 3499B is a two-slot controller and the N2276A and N2276B require three slots.
2005-03-25 FAQ
Are there separate licenses for 34970A and 34980A instruments?
Yes. Each instrument uses a specific Data Logger Pro product number.
2007-11-19 FAQ
Can Agilent build my custom L4490A/L4491A solution?
Please visit "www.agilent.com/find/AD-systems" or see Agilent’s Channel Partners and Solution Providers at "www.agilent.com/find/channelpartner"
2008-04-07 FAQ
Can Excel control a scan, and make and record measurements using the 34980A?
Use the 34980A IntuiLink add-in or the Excel Macro language.
2007-01-22 FAQ
Can I add another 34945EXT to the L449XA?
The L4491A option 002 is recommended if an additional 34945EXT is required.
2008-04-04 FAQ
Can I assign names to switches when using the L4490A/L4491A?
Yes. At the web interface, right click on the switch to assign a name.
2008-04-07 FAQ
Can I close all of the channels in the reed cards (ie. 34923A, 34924A, and 34933A) at the same time when working in switch mode?
No. Due to power dissipation, you cannot close all of the channels in the reed cards simultaneously when working in switch mode.
2008-08-15 FAQ
Can I mix 34980As and 34970As in the same configuration?
You can have a combination of one 34980A and one or two 34970As in a configuration.
2007-11-19 FAQ
Can I mount a fan in the L449XA mainframe for cooling?
Yes, there is a fan mounting location on the rear panel for a 60mm (50mm mounting hole-to-hole spacing).
2008-04-04 FAQ
Can I mount switches or connectors on the L449XA front or rear panel?
Yes, blank panels or pre-drilled panels are available.
2008-04-04 FAQ
Can I Perform Open/Short Test Using 34980A?
Yes. There are two ways you can setup using the 34980A to perform this test.
2008-06-25 FAQ
Can I record the L4490A/L4491A I/O traffic?
Yes, select the "System Overview" button in the web browser to "Generate Report".
2008-04-07 FAQ
Can the 34980A automatically open or close Switches based on Alarm Conditions?
Yes. The 34980A can use the Sequence feature to allow the instrument to automatically open or close switches in the event of an alarm.
2006-08-17 FAQ
Can the 87302C/87303C/87304C hybrid dividers be utilized in power combining applications?
Yes, the hybrid dividers can be utilized in power combining applications.
2009-03-17 FAQ
Can the L4490A/L4491A mainframe be password protected when using LAN?
Yes, instructions for using password protection can be found in the web interface.
2008-04-07 FAQ
Can the measurements be displayed on the 34980 front-panel?
No.
2006-10-19 FAQ
Can the measurements taken be read from the 34980 Data Acquisition Front Panel?
No
2006-06-22 FAQ
Can you advise of alternatives to printing and acquiring screen images from the various Agilent Analyzers equipped with only a GP-IB interface?
2009-03-17 FAQ
Comparing and Contrasting the Agilent Technologies 8710x and 8720x Family Switches
2009-03-17 FAQ
Do I have to buy distribution boards for the L4490A/L4491A?
Yes, the distribution boards are required to route the control signals to the switches and attenuators.
2008-04-04 FAQ