What is the size and resolution of the Agilent X-Series (PXA/MXA/EXA/CXA) Signal Analyzer display?
Click here for details...

FAQ 2009-09-26

Is there an Ecal that covers the lower frequency of the E5071C down to 9 kHz?
Yes, the N4431B 4-port Ecal now supports down to 9 kHz.

FAQ 2009-08-30

How to calculate the accuracy for U1731A/U1732A Capacitance Measurements?
The accuracy is calculated using the formula in the datasheet...... The Example......

FAQ 2009-07-16

How to calculate the accuracy for U1731A/U1732A Inductance Measurements?
The accuracy is calculated using the formula in the datasheet...... The Example......

FAQ 2009-07-16

How does Agilent specify the bandwidth of the N1021B probe?
The one-way bandwidth of the probe can be estimated using a simplified equation ...

FAQ 2009-06-18

Does the Agilent Measurement Manager (AMM) run on Window Vista operating system?
Yes. The Agilent Measurement Manager (AMM) rev. 1.8.3.0 and above will able to run on Windows Vista ...

FAQ 2009-06-10

What are the frequency limitations on the various probes utilized with the Agilent 85070E Dielectric Probe Kit and why?
The 85070E Dielectric Probe options 020, 030 and 050 have maximum frequeny via the E4991A Impedance Analyzer of 3 GHz.

FAQ 2009-05-28

Can the 346C-K01 be used below 1 GHz?
This special option is not calibrated or characterized below 1 GHz.

FAQ 2009-04-28

What is option H12 for the E4418B and E4419B EPM Series Power Meters?
Option H12 for the E4418B and E4419B EPM Series Power Meters provides an improved power level accuracy specification....

FAQ 2009-04-12

Do the mean, min, and max values of the InfiniiVision oscilloscopes measurement statistics refer to one signal on the screen or all previously capt...
They refer to the "Count" number of captured waveforms ...

FAQ 2009-03-30

What is the certification (and recertification) process for calibration kit torque wrenches?

FAQ 2009-03-17

Is the Rdc measurement accuracy of the 4287A better than that of the 4286A?

FAQ 2009-03-13

What is the output impedance of the 4287A?
Nominal output impedance is 50 ohms.

FAQ 2009-03-11

What benefits can I get by replacing the 4286A with the 4287A?

FAQ 2009-03-11

What is the minimum sensitivity of the N897xA NFA Series?
Sensitivity is not a specified parameter

FAQ 2009-02-09

How can I access to the maximum memory depth (32M/16M) as stated in the U2701A/U2702A Modular Oscilloscope's datasheet?
You can see the effects of maximum memory depth 32/16 Mpts in zoom mode….

FAQ 2009-02-04

How do I calculate the dc vertical gain accuracy of a U2701A/U2702A USB Modular Oscilloscope?
The dc vertical gain accuracy of a U2701A/U2702A USB Modular Oscilloscope depends on the error values in the measured value....

FAQ 2009-02-04

What is the output impedance of the 4285A?

FAQ 2009-01-14

Does the Agilent Measurement Manager (AMM) support regional language settings other than English (US)?
Yes, the Agilent Measurement Manager (AMM) supports regional language settings other than English (US)….

FAQ 2009-01-12

Is the accuracy of the impedance measurement specified when the 4395A/4396B Option 010 is used with the 87512A?
No, the accuracy of the impedance measurement values obtained by using the 4395A/4396B with the 87512A is not specified.

FAQ 2008-11-16

Can the spectrum analyzer mode of the 4395A display noise level below 0.0001 µV / sqrt (Hz) in noise measurement mode?
No, the 4395A can't display noise level below 0.0001 µV / sqrt (Hz) in noise measurement mode.

FAQ 2008-11-16

What does the Input Impedance in Table 11-24 of E4980A User's Guide and Table 39 of E4980A datasheet mean and how should it be applied?
The Table 11-24 and Table 39 describe input impedance of DC bias current monitor.

FAQ 2008-11-12

How accurately does the 4338B measure high resistance?
The 4338B accuracy in high resistance measurement is degraded because the maximum measurement range is limited to 100 k ohms.

FAQ 2008-11-11

What is the signal source output impedance of the 4338B?
The signal source output impedance is 1 ohm +/- 0.2 ohms (not specified).

FAQ 2008-11-11

ESA-L1500A: Spectrum Analyzer Frequency Reference

FAQ 2008-10-08