Contact an Expert

Technical Support

Test & Measurement

Find by Product Model Number: Examples: 34401A, E4440A

1-25 of 131

Sort:
What Configuration issues are there with option AYQ, Quasi Peak Detector in the ESA-E Series of Spectrum Analyzers?
View the compatibility issues here....

FAQ 2012-12-05

What external mixers will work with my PXA/mmW EXA and how do I order them?
Currently, the N9030A PXA/mmW EXA with Option EXM will work with either the 11970 Series (with the exception of the 11970K) or ) or external mixers from other vendors such a OML Inc. mixers.

FAQ 2012-10-17

Which Agilent oscilloscopes have a 10 MHz reference input/output?
6000 Series, 6000L Series, 7000A Series, 7000B Series, 9000 Series, 54850 Series (Output only), 80000A Series, 80000B Series, 90000A Series and 90000 X-Series

FAQ 2012-09-29

How to calculate the bit clock frequency under DSI interface of U8903A?
The Bit clock frequency can be calculated by multipling the number of channels,bit length and frame clock frequency.

FAQ 2012-08-25

Are there limit lines with pass/fail status on FieldFox instruments?
Yes, all the modes include limit lines and pass/fail status indicators.

FAQ 2012-08-20

Will FieldFox instruments be able to differentiate between internal and external zeroing when using the U200xA/B/H USB power sensors?
FieldFox instruments cannot do this differentiation, but FieldFox allows you the choice of external zeroing.

FAQ 2012-08-20

Can I use an Agilent 85032E Cal Kit with FieldFox instruments?
Yes. You can use an 85032E Cal kit with FieldFox.

FAQ 2012-08-20

Is it possible to modify the scale on the return loss plot when the measurement is configured for Return Loss & DTF on a FieldFox instrument?
There is no method to change the scale on the upper Return Loss (top) plot.

FAQ 2012-08-20

How Can I Find What I Need in a Signal Analyzer Recording Faster?
If you have a very long Signal Analyzer recording, it is sometimes difficult to find the area of interest. There is no really good tool for this problem at this time, but here are some suggestions.

FAQ 2012-08-17

FieldFox will not recognize my USB memory stick. What can I do?
Most USB memory sticks work well with the FieldFox.

FAQ 2012-08-17

Which is Most Accurate: CalReady, QuickCal (Without Load), or 2 Port Calibration?
When nothing connected at the end of RF port, CalReady is the most accurate calibration method at test port.

FAQ 2012-08-15

Why won't my Signal Analyzers Display Pulse Type Signals Properly?
These signals may be missed if the Sweep Acquisition setting is on Auto. We recommend using a Sweep Acquisition setting of 50 or 100 for GSM signals.

FAQ 2012-08-15

What is the maximum DC input for PSA Series Spectrum Analyzer?
AC/DC coupling values found here...

FAQ 2012-05-30

For the PSA Series spectrum analyzer, is gated sweep capability required for options 212 (TD-SCDMA Modualtion Analysis) and 213 (HSDPA / 8PSK for T...
No, Gated sweep is not required.

FAQ 2012-05-30

Does the E7495A/B Base Station Test Set allow simultaneous operation of the CW and complex source in Spectrum Analyzer mode, Channel Analyzer mode,...
Yes. This support was added for A.02.10 firmware in January 2004.

FAQ 2012-05-29

Can the E4406A or PSA Series cdmaOne personality (Option BAC) make power timing and phase measurements?
Yes. In the cdmaOne personality you will first need to change the Measure Method to Timing and Phase under the Measure Setup key and then change the view to Power Timing and Phase under the View/Trace key.

FAQ 2012-05-29

What file formats does the 89601A VSA software support for signal waveforms?
Recorded data from the following files can be interpreted by the 89600: ASCII (.txt and .csv), Binary (89600 SDF .sdf, .dat), Binary (E3238 .cap), Binary (N5510A .bin), MATLAB 7 (or earlier, .mat)

FAQ 2012-05-28

Do the E4406A and PSA Series support Complementary Cumulative Distribution Function (CCDF) measurement for cdmaOne?
Yes. The Power Statistics CCDF measurement is not in the cdmaOne personality (Option BAC), but it does come standard in the Basic measurement personality for E4406A and in the Spectrum Analysis mode for PSA and can be used to measure cdmaOne sign...

FAQ 2012-05-26

Do the E4406A, PSA Series and 89600 VSA Software report Peak Code Domain Error for W-CDMA and cdma2000?
Yes. The screen capture below shows a W-CDMA Modulation Accuracy measurement on the E4406A and PSA Series, and Peak Code Domain Error is reported in the results table.

FAQ 2012-05-26

Which Application Notes are Most Relevant to the PSA Series Spectrum Analyzer?
This page contains links to application notes that are relevant to PSA Series spectrum analyzers.

FAQ 2012-05-11

How do I make the signal list compare measurements made with the detectors used to different limit lines in my MXE EMI Receiver?
Meas Setup, Detectors (Measure)...

FAQ 2012-05-10

How do a take a sweep with both the Quasi-Peak and EMI Average detector at the same time with an MXE EMI Receiver?
Switch to EMI Receiver mode...

FAQ 2012-05-10

Why do I get a Meas Uncal message when I select either the Quasi-Peak or EMI Average detector for taking a full band sweep with the MXE EMI Receiver?
Sweeptime has reached its maximum. See complete FAQ for further details...

FAQ 2012-05-10

What is the revision history for the 89601A, VSA software?
New feature list with each software release...

FAQ 2012-03-16

Do the ENA provide a probe power connection for active probes?

FAQ 2012-03-16

1 2 3 4 5 6 Next