Is the state file compatible between the ENA-L and the ENA?
No.

FAQ 2009-02-24

Is it possible to supply a DC voltage to a device under test with the E5091A?
Yes. The E5091A is capable of providing a DC voltage to a device under test.

FAQ 2009-02-24

On the ENA / ENA-L can I use the embedded GPIB Interface to control and perform a power meter calibration?
An Agilent 82357A/B USB/GPIB interface is required.

FAQ 2009-02-24

Does the ENA-L have AUX input to measure DC level?
No. The ENA-L doesn't have AUX input.

FAQ 2009-02-23

On the ENA-L, Can I use point trigger function?
No. The ENA-L doesn't have the point trigger function.

FAQ 2009-02-23

Does the ENA-L have "Default Calibration data" like the 871x?
Yes. Turning the correction off is equivalent feature to "Default Calibration Data".

FAQ 2009-02-23

Is it possible to connect to the ENA / ENA-L with the IntuiLink application, using the USBTMC interface?
Because some dll files does not support the USBTMC interface, it is not possible to connect the ENA via USBTMC with Agilent IntuiLink ENA version 3.0, or earlier.

FAQ 2009-02-23

With the Vector Mixer Calibration (VMC) technique, is it possible to characterize mixers below the lowest operating frequency of the ENA?
Yes.

FAQ 2009-02-23

On the ENA-L, can I use Alt sweep ON/OFF function like the 871x?
No. It is always Alt sweep ON in the ENA-L.

FAQ 2009-02-23

85070E/85071E: What Are the Part Numbers for 7mm and 3.5mm Airlines for Materials Measurements?
7mm airline 85051-60010 3.5mm airline 85053-60008

FAQ 2009-02-17

My Agilent PNA Family Network Analyzer no longer recognizes the external multiport test set. How do I fix this anomaly?

FAQ 2009-02-12

Is the Agilent Intuilink PNA application supported while the analyzer's frequency offset mode (option 080) is activated?
Agilent Intuilink PNA is not supported when the analyzer is in the frequency offset mode.

FAQ 2009-02-10

Does 85070E and 85071E software run on Windows Vista?
Windows Vista must be configured to allow the 85070E and 85071E to write files to the Program Files folder.

FAQ 2009-02-05

How can I clear an error message shown on the display of the 4294A/4395A/4396B by using GPIB command?
Send the "KEY 18" command to the instrument.

FAQ 2009-01-08

What features or functions are different between ENA and PNA-L?
Followings are the difference between the ENA and the PNA-L...

FAQ 2008-11-27

Can the 4395A/4396B read the cal data from the disk that comes with the cal kits such as the 85033D, 85039A, 85039B, etc?
No, the 4395A/4396B can't read the cal data from the disk furnished with these cal kits.

FAQ 2008-11-18

The VOLT unit is selectable in the Format menu when the 4395A/4396B is set to spectrum analyzer mode. Is this RMS value or peak value?
It stands for RMS value.

FAQ 2008-11-17

Why is "OVERLOAD" message sometimes displayed in Network Analyzer mode of the 4395A? How can I avoid this error message?
The OVERLOAD message on the 4395A Network Analyzer mode is often displayed when Sweep Start frequency is lower than 5 kHz and a wide IFBW is selected.

FAQ 2008-11-17

Is there any prober for measuring an on-board chip device with the 4396B option 010?
Agilent doesn't supply the relevant fixture, but a third party provides some probers available for the on-board device measurements using the E4991A.

FAQ 2008-11-17

How can I set the unit of the marker to "dBV / sqrt (Hz)" in the noise measurement (spectrum analyzer mode) of the 4396B?
To change the unit of the marker value to "dBV / sqrt (Hz)", perform the following procedure:

FAQ 2008-11-17

How can I order the upgrade kits of the 4396B?
The model numbers of available upgrade kits for the 4396B options are as follows.

FAQ 2008-11-17

Is there any requirement for the monitor display that can be used as an external monitor of the 4395A / 4396B?
Color monitors supporting VGA can be used as an external monitor of the 4395A / 4396B.

FAQ 2008-11-17

What accessories can be used for the 4396B?
Please refer to "Available Accessories" section in the 4396B Configuration Guide.

FAQ 2008-11-17

Can the spectrum analyzer mode of the 4396B measure the power of a digital modulation signal such as QAM?
Yes, but it works only when the signal is periodic and the 4396B with option 4396B-1D6 (Time-gated spectrum analysis) is used.

FAQ 2008-11-17

What kind of benefits does the 4396B's file transfer function have?
The "File Transfer Function" of the 4396B allows you...