8483A Power Sensor Calibrating
|
2002-06-27
|
FAQ
|
|
|
|
|
Are the N8480 Series Power Sensors compatible with the 53148A counter/power meter/DVM?
No, the N8480 Series Power Sensors are not compatible with the 53148A counter/power meter/DVM.
|
2009-02-04
|
FAQ
|
|
|
|
|
Are the N848xA Power Sensors (both STD and CFT options) compatible with the obsolete 435, 436, 437 and 438 Power Meters?
No, the N848xA Power Sensors are not compatible with the obsolete 43x Power Meters.
|
2009-02-04
|
FAQ
|
|
|
|
|
Are the N848xA Power Sensors drop-in replacements for legacy 848xA Power Sensors?
No, the N848xA option CFT power sensors are not drop-in replacements for the legacy 848xA power sensors….
|
2009-02-04
|
FAQ
|
|
|
|
|
Can I use a different attenuator for my high power sensor rather than the attenuator that shipped with the RF power sensor?
No, you must use the attenuator that shipped with the power sensor.
|
2009-11-08
|
FAQ
|
|
|
|
|
Can I use D-type linearity to calibrate the V8486A Power Sensor?
Yes, you can use D-type linearity to calibrate the V8486A Power Sensor....
|
2008-09-25
|
FAQ
|
|
|
|
|
Do changes in the test signal input power level affect the Agilent EPM-Series power meter's measurement speed?
Yes, the test signal input power level will affect both the power meter and sensor’s "settling times".
|
2006-07-20
|
FAQ
|
|
|
|
|
How can I make my E4418/9A Power Meter compatible with the E930xA/B/H Power Sensor?
To make the E4418A or E4419A Power Meter compatible with the E930xA, E930xB or E930xH Power Sensors, you must upgrade the firmware and DSP….
|
2009-02-04
|
FAQ
|
|
|
|
|
How can I prevent Power Sensors from damage?
To prevent Power Sensors (eg. E4412A, E4413A, N8481A, N8482A, N8485A, U2000B, U2000H, U2001B, U2001H, U2002H etc.) from damage, refer to….
|
2009-02-04
|
FAQ
|
|
|
|
|
How can I use a computer to monitor when the power meter is done with a Secure Erase?
The “*OPC?” command can be used with a long IO timeout.
|
2009-10-20
|
FAQ
|
|
|
|
|
How do I change the power meter's system model number (E4418A or E4419A) to be the same as the physical model number (E4418B or E4419B) ?
To change the power meter's system model number from E4419A to E4419B and from E4418A to E4418B, use the following SCPI command:….
|
2008-10-16
|
FAQ
|
|
|
|
|
How do I convert dBm to dBmV since power meter display unit is in dBm?
dBmV = dBm + 47
|
2009-11-08
|
FAQ
|
|
|
|
|
How do I convert percentage(linear) to dB(logarithmic) since most the accuracy value stated in power meter datasheet is in percentage?
dB = 0.0432
|
2009-10-20
|
FAQ
|
|
|
|
|
How do I get Instrument Drivers for Agilent Test & Measurement Products?
From the CD shipped with the instrument or from the product technical support web page for the instrument.
|
2009-05-01
|
FAQ
|
|
|
|
|
How do you “zero” the N848xA sensors?
The N848xA Power Sensors are zeroed by removing the RF power from the input sensor and pressing the Zero button on the power meter.
|
2009-02-04
|
FAQ
|
|
|
|
|
How does the measurement accuracy of the N848xA Power Sensors compare to that of the legacy 848xA sensors?
The N848xA Power Sensors are as accurate if not more accurate than the legacy 848xA sensors they replace….
|
2009-02-04
|
FAQ
|
|
|
|
|
Is the N8262A power meter compatible with the N8480A Series Power Sensors?
No, the N8262A power meter with the firmware revision A2.02.00 is not compatible with the N8480A Series Power Sensors.
|
2009-02-04
|
FAQ
|
|
|
|
|
New Precision Type-N connectors
Agilent power sensors now come with the precision type-N connector as standard............
|
2002-09-03
|
FAQ
|
|
|
|
|
Power Sensors:ANSI Z540 Compliant Calibration Option
|
2002-06-27
|
FAQ
|
|
|
|
|
V8486A Calfactors
|
2002-06-27
|
FAQ
|
|
|
|
|
V8486A: Frequency Range
|
2002-06-27
|
FAQ
|
|
|
|
|
What is the difference between the closed-loop and opened-loop methods in power sensors?
In power sensors, the closed-loop method uses a bridge feedback of substituted DC power while the opened-loop method….
|
2008-09-25
|
FAQ
|
|
|
|
|
What is the difference between the STD and CFT options for the N848xA Power Sensors?
The N848xA option CFT behaves like legacy the 848xA power sensors. The option STD behaves like the Agilent E-series average power sensors….
|
2009-03-04
|
FAQ
|
|
|
|
|
What is the power band switching level on the N848xA Power Sensors?
The N848xA option STD Power Sensors have two RF power bands….
|
2009-02-04
|
FAQ
|
|
|
|
|
When a B-model or H-model of the E-Series Power Sensors (with a 30 dB attenuator attached) is connected to a EPM Series, EPM-P Series or P-Series Power Meter, why is the power level shown 0 dBM?
When a B- or H-model of the E-Series Power Sensors is connected to a EPM, EPM-P or P-Series Power Meter, the power level is 0 dBm because…..
|
2008-09-25
|
FAQ
|
|