Technical Support
Test & Measurement
Refine the List
By Type of Content
- Specifications (25)
- Manuals (69)
- Application Notes (44)
- Brochures & Competitive Overviews (8)
- Selection & Configuration Guides (5)
- Demos (3)
- Articles & Case Studies (1)
- Press Releases (2)
By Product Category
-
All Product Categories
-
Oscilloscopes, Analyzers, Meters
-
Frequency Counter Products
- 53200 Series RF & Universal Frequency Counters/Timers (350 MHz) (24)
- 53140 Series Microwave Counters (18)
- 53150 Series CW Microwave Counters (20)
- RF and Universal Frequency Counters (225 MHz) (32)
- U1050A Acqiris Twelve-channel CompactPCI Time-to-Digital Converter (12)
- U1051A Acqiris Six-channel CompactPCI Time-to-Digital Converter (9)
- Z2090B-170 Pulse Analyzer System (2)
-
Frequency Counter Products
-
Oscilloscopes, Analyzers, Meters
101-125 of 157
|
Simplified Analysis of Phase-Locked Loop Capture and Tracking Range (AN 1200-7)
The Agilent 53310A's ability to measure and display a signal's continuous frequency over time makes dynamic frequency analysis of PLLs easy. A direct measure of the PLL's capture and tracking range is obtained by monitoring the output frequency while the PLL is forced to go in and out of lock. A...
Application Note 2000-08-01 |
|
|
Quick Identification of Periodic Jitter Sources (AN 1200-4)
The Agilent 53310A is an easy-to-use, inexpensive tool for displaying time interval measurements versus time. Any repetitive pattern in the jitter is immediately apparent. The 53310A's analysis features readily give peak-to-peak and periodic rate information. Taking all of these clues together...
Application Note 2000-08-01 |
|
|
Peak Deviation and Center Frequency Measurements for CT2 and DECT Radios (AN 1200-12)
The use of digital modulation in mobile communications systems is growing rapidly. Information in the form of 1s and 0s is often transmitted as two different frequencies. This is known as minimum shift keying or GMSK if the data is filtered. Measuring the deviation accurately on a bursted signal...
Application Note 2000-08-01 |
|
|
Examine Channel Switching Characteristics of Cellular Radios (AN 1200-10)
The Agilent 53310A's ability to measure and display a signal's continuous frequency over time makes cellular communications channel switching analysis easy. A direct frequency profile of channel switching is provided on an easy-to-interpret display. Measurement markers allow you to quickly verify...
Application Note 2000-08-01 |
|
|
Fast Characterization of Pulse-Width Encoded Data (AN 1200-5)
The built in fast histogram capability of the Agilent 53310A is a simple and easy way to analyze pulse width encoded data. In less than a second, it takes a hundred thousand pulse width measurements, rearranges the measurements in value order, then displays how often a given value occurred.
Application Note 2000-08-01 |
|
|
Single Shot Frequency Profiling of Chirped Radars Made Easy (AN 1200-8)
This Application Note describes the Agilent 53310A's ability to measure and display a signal's continuous frequency over time makes dynamic frequency analysis of radar pulses easy. Views of single-shot chirp linearity are obtained by measuring the continuous frequency of the IF chirp. The chirp...
Application Note 2000-08-01 |
|
|
Simplified Motor Spin-up Analysis (AN 1200-1)
This Application Brief offers the Agilent 53310A Modulation Domain Analyzer as a solution to the problem of characterizing a motor's
performance without the need for external controller.
Application Note 2000-08-01 |
|
|
Direct Characterization of Motion Control Systems (AN 1200-2)
This Application Brief is one of a series. It demonstrates how the Agilent 53310A makes it easy to capture and view velocity profiles, without the need for an external controller.
Application Note 2000-08-01 |
|
|
VCO Step Response Analysis Made Easy (AN 1200-3)
The Agilent 53310A allows for an easy-to-use single pass technique for displaying the VCO's output frequency versus time. It makes rapid, high resolution frequency measurements in a back-to-back manner. This yields a full analysis of a VCO's step response in a single pass. For applications that...
Application Note 2000-08-01 |
|
|
Automatic Frequency Settling time Measurement Speeds Time-to-Market for RF Designs (AN 1275)
This Application Note addresses considerations for the RF designer. It presents the Agilent 53310A with Option 031, which was developed
specifically for digital RF communications measurement needs, offering significant advantages over past techniques.
Application Note 2000-07-01 |
|
|
53131A/132A Universal Counter Operating Guide
53131-90055; Contains a quick reference guide, getting started guide, front panel operation, and specifications.
User Manual 1999-10-01 |
|
|
4 Hints for Making Better Microwave Counter Measurements
This Product Note provides four pertinent hints for making better microwave counter measurements, describes the advantages of using a microwave counter, and deals with the unique measurement problems created by the advancement in counter technology.
Application Note 1998-09-01 |
|
|
5334B Brochure
Brochure 1998-05-01 |
|
|
E1747A Timing Pattern Analysis Software User Guide
Part Number: E1725-90013 (Apr98). The E1747A is a discontinued product; this manual is provided for information only.
User Manual 1998-04-01 |
|
|
E1725C/E1740A Time Interval Analyzer - Getting Started Guide
Part Number: E1725-90012 (Apr98). The E1725C is a discontinued product; this manual is provided for information only.
Quick Start Guide 1998-04-01 |
|
|
E1725C/E1741A Time Interval Analyzer - Getting Started Guide
Part Number: E1725-90011 (Apr98). The E1725C is a discontinued product; this manual is provided for information only.
Quick Start Guide 1998-04-01 |
|
|
Fundamentals of Time Interval Measurements (AN 200-3)
This classic Application Note provides a fundamental background on measurements of time-related events with electronic time interval counters. This Application Note is for information only. Agilent no longer sells or supports these products.
Application Note 1997-06-01 |
|
|
Understanding Frequency Counter Specifications (AN 200-4)
This classic Application Note was aimed at the reader who might be unsure of particular specifications in frequency counter data sheets. It is still considered like a textbook and is always in demand.
Application Note 1997-05-01 |
|
|
Fundamentals of Microwave Frequency Counters (AN 200-1)
This somewhat lengthy, classic Application Note addresses the microwave counter designer's need for down-conversion techniques. It describes and compares techniques and outlines additional
considerations in choosing a microwave counter. Includes some applications of the Agilent 5342A.
Application Note 1997-05-01 |
|
|
Fundamentals of the Electronic Counters (AN 200)
This classic Application Note is aimed at introducing to the reader the basic concepts, techniques and the underlying principles that
constitute the common denominator of this myriad of counter products. It discusses the fundamentals of the conventional counter, the types of measurements it can...
Application Note 1997-03-01 |
|
|
5350/51/52B Operating Manual - Jan96
05350-90052. The 5350 series of counters are discontinued, and this manual is provided for information only.
Operation Manual 1996-01-01 |
|
|
5347A/48A Microwave Counter/Power Meter Operating and Programming Manual
Part Number: 05348-90025 (Dec95). The 5347A/48A is a discontinued product; this manual is provided for information only.
Operation Manual 1995-12-01 |
|
|
5371A Frequency and Time Interval Analyzer Programming Manual
Part Number: 05371-90032 (Jun95). The 5371A is a discontinued product; this manual is provided for information only.
Programming and Syntax Guide 1995-06-01 |
|
|
E1740A Time Interval Analyzer User Guide
Part Number: E1740-90005 (Jun94). The E1740A is a discontinued product; this manual is provided for information only.
User Manual 1994-06-01 |
|
|
5334A/B Universal Counter Operating and Programming Manual
Part Number: 05334-90047 (Dec93).
The 5334A and 5334B are obsolete products; this manual is provided for information only.
Operation Manual 1993-12-01 |
|
