Does Option 320 require that I have Option UNU or UNW on the X-Series signal generators?
Yes, Option 320, pulse train generator, requires Option UNW, narrow pulse modulation. Option UNU, pulse modulation, is not an option on the X-Series signal generators.

FAQ 2012-04-30

What is the OS (operating system) of the X-Series signal generators?
Windows® CE

FAQ 2012-04-30

Is the output power improved on the X-Series signal generators?
Yes, specified output power changed from +23 dBm to +24 dBm for MXG. For both MXG and EXG X-Series signal generators, standard output power has improved significantly. See the data sheet for more details.

FAQ 2012-04-30

Will the N5171B and N5172B EXG X-Series signal generator have an OCXO option for improved drift rate?
No

FAQ 2012-04-30

Does N5181B or N5182B MXG Option UNY/UNX have backward code compatibility with E8663D or 8663D signal generators?
Yes, the N5181B and N5182B MXG Option UNY/UNX has the same SCPI as PSG E8663D. E8663D is the replacement of 8663D with BWCC (backward code compatibility).

FAQ 2012-04-30

Can you bypass the internal reference chain with clean rubidium source on the X-Series signal generators?
The 10 MHz path is very clean and works with an external reference. The 1-50 MHz tunable path is noisier, see the data sheets for more details.

FAQ 2012-04-30

What are the plans to upgrade the N5102A DSIM, if I want it to go to 160 MHz BW on the N5182B MXG or N5172B EXG X-Series signal generators?
DSIM will be able to run up to 200MSa/sec.

FAQ 2012-04-30

Is the phase coherency supported on the X-Series signal generators?
Yes, with Option 012, LO in/out for phase coherency.

FAQ 2012-04-30

Can you master/slave MXG and EXG or must they all be the same model number?
You can master/slave first generation MXG N5182A with the N5182B MXG and N5172B EXG X-Series signal generators. The N5172B or N5182B must be the master.

FAQ 2012-04-30

Does Option UNY, enhanced low phase noise, require Option UNX, low phase noise,on the X-Series signal generators?
No, they are independent options with different levels of phase noise performance above 3 GHz.

FAQ 2012-04-30

Is the tuning speed the same as switching speed on the X-Series signal generators?
Yes, switching speed is the same as tuning speed.

FAQ 2012-04-30

N7615B Signal Studio Software and 30-Day Free Trial
Update your existing Signal Studio software, start a free trial, or request the Signal Studio Software DVD.
Previous Versions

Computer Software Current Version: 3.5.0.0 | 2012-04-24

Using the E8267D PSG Vector Signal Generator in a System
Browse through this index of resources generated to ease your test system design challenge

FAQ 2012-03-30

I downloaded the Service Support Software for the E44xxB ESG-AP/DP from our website. The software is asking for a username and password. What is t...
The E44xxB ESG-AP/DP Service Support Software username and password are provided.

FAQ 2012-03-13

I downloaded the Service Support Software for the E44xxB ESG-A/D from our website. The software is asking for a username and password. What is the...
The E44xxB ESG-A/D Service Support Software username and password are provided.

FAQ 2012-03-13

What is the polynomial to generate the PN9 sequence in the ESG-D Series RF signal generator?
We follow the ITU standards for PN sequences.

FAQ 2012-03-13

I downloaded the Service Support Software for the 8648X from our website. The software is asking for a username and password. What is the username...
The 8648 Service Support Software username and password are provided.

FAQ 2012-03-13

ESG and ESG-D Series: Selectivity Measurements
The ESG-D Series provides the appropriate adjacent channel power (ACP)

FAQ 2012-03-13

Why doesn't the Agilent License Manager connect to my ESG?
Your ESG needs firmware revision C.04.84 or above...

FAQ 2012-03-02

How do I upgrade the PSA Series Memory Upgrade Option ANE?
The memory can be upgraded to 64 Megabytes by ordering E4440AU Option ANE. Click here for additional information.

FAQ 2012-02-26

How do I configure the PSA Series Spectrum Analyzer to make Phase Noise Measurements?
The PSA Series Phase Noise measurement personality Option 226 is available to make Phase Noise measurements.Click here for additional information.

FAQ 2012-02-26

My PSA Series Spectrum Analyzer Shows error +605 Data Corrupt or Stale, NRAM copy of !....
The non-volatile RAM battery has expired. The replacement battery P/N is 1420-0314C. Click here for additional information.

FAQ 2012-02-26

Does the E444xA PSA series have RMS Detection?
Yes, the PSA has a complete set of detection modes including normal, positive/negative peak, sample, and RMS.

FAQ 2012-02-25

Can I apply a DC offset voltage to the RF output of ESG/PSG?
No, ESG/PSG (and all our RF/microwave SG) do not have a capability of applying a DC offset to their RF output signal.

FAQ 2012-02-20

Where can I find the PC requirements for Signal Studio applications?
PC requirements for all Signal Studio applications can be found in the Signal Studio Software Installation Guide. More...