Can you master/slave MXG and EXG or must they all be the same model number?
You can master/slave first generation MXG N5182A with the N5182B MXG and N5172B EXG X-Series signal generators. The N5172B or N5182B must be the master.

FAQ 2012-04-30

Can we add a SCPI logger/history for past few commands on the X-Series signal generators?
Yes, we have this capability.

FAQ 2012-04-30

Do we offer an external divider option to cover the heterodyne band phase noise performance on the X-Series signal generators?
We have the 70429A-K95 divider that can be used as an external divider for frequencies <250 MHz.

FAQ 2012-04-30

Can we support atmospheric conditions with N7609B GPS on the N5182B MXG or N5172B EXG X-Series signal generators?
Yes.

FAQ 2012-04-30

Will Options 430, 431 and 432 require Option 656 but not require Option 660 for ARB capability?
Yes, this is true for the N5182B MXG or N5172B EXG X-Series signal generators.

FAQ 2012-04-30

What is the size and format of the removable memory (SD card) on the X-Series signal generators?
8 GB SD card, RAW storage. This is available with Option 006 instrument security and removable memory card.

FAQ 2012-04-30

Is the pulse generator specification still the same with ALC On/Off on the X-Series signal generators?
Yes, it still cuts off at <2µs, however, open loop power accuracy has improved with or without power search being run. In most cases, you will see tenths of dB accuracy without running power search. This is a significant improvement over first-generation MXG.

FAQ 2012-04-30

Can customers use custom digital modulation in ARB mode?
Yes, but the data will be a fixed, random pattern.

FAQ 2012-04-30

What does the S/N mode affect negatively on the X-Series signal generators? Why not leave it on all the time?
The harmonics can degrade with S/N mode on.

FAQ 2012-04-30

Will there be drivers available for the N5181B or N5182B X-Series signal generators?
Yes, 32 and 64 Bit IVI com, IVI C and MATLAB drivers are available. LabView driver is planned for late 2012.

FAQ 2012-04-30

How can I generate TETRA and DECT signal for basic interference testing in many compliance test houses, which are bursted, just like the real standard
You can use PRAM to simulate spectrally correct signals for TETRA and DECT for bursted signals. See the X-Series User’s Guide for further information.

FAQ 2012-04-30

N7615B Signal Studio Software and 30-Day Free Trial
Update your existing Signal Studio software, start a free trial, or request the Signal Studio Software DVD.
Previous Versions

Computer Software Current Version: 3.5.0.0 | 2012-04-24

Using the E8267D PSG Vector Signal Generator in a System
Browse through this index of resources generated to ease your test system design challenge

FAQ 2012-03-30

N8211A IVI-COM Driver
Driver file available for download...

Unspecified 2012-03-23

I downloaded the Service Support Software for the E44xxB ESG-AP/DP from our website. The software is asking for a username and password. What is t...
The E44xxB ESG-AP/DP Service Support Software username and password are provided.

FAQ 2012-03-13

I downloaded the Service Support Software for the E44xxB ESG-A/D from our website. The software is asking for a username and password. What is the...
The E44xxB ESG-A/D Service Support Software username and password are provided.

FAQ 2012-03-13

What is the polynomial to generate the PN9 sequence in the ESG-D Series RF signal generator?
We follow the ITU standards for PN sequences.

FAQ 2012-03-13

I downloaded the Service Support Software for the 8648X from our website. The software is asking for a username and password. What is the username...
The 8648 Service Support Software username and password are provided.

FAQ 2012-03-13

ESG and ESG-D Series: Selectivity Measurements
The ESG-D Series provides the appropriate adjacent channel power (ACP)

FAQ 2012-03-13

Why doesn't the Agilent License Manager connect to my ESG?
Your ESG needs firmware revision C.04.84 or above...

FAQ 2012-03-02

How do I configure the PSA Series Spectrum Analyzer to make Phase Noise Measurements?
The PSA Series Phase Noise measurement personality Option 226 is available to make Phase Noise measurements.Click here for additional information.

FAQ 2012-02-26

My PSA Series Spectrum Analyzer Shows error +605 Data Corrupt or Stale, NRAM copy of !....
The non-volatile RAM battery has expired. The replacement battery P/N is 1420-0314C. Click here for additional information.

FAQ 2012-02-26

How do I upgrade the PSA Series Memory Upgrade Option ANE?
The memory can be upgraded to 64 Megabytes by ordering E4440AU Option ANE. Click here for additional information.

FAQ 2012-02-26

Does the E444xA PSA series have RMS Detection?
Yes, the PSA has a complete set of detection modes including normal, positive/negative peak, sample, and RMS.

FAQ 2012-02-25

Can I apply a DC offset voltage to the RF output of ESG/PSG?
No, ESG/PSG (and all our RF/microwave SG) do not have a capability of applying a DC offset to their RF output signal.

FAQ 2012-02-20