Fragen & Antworten:
Discontinued Function Generators [Discontinued]

Blättern Fragen & Antworten

Sprache:Deutsch | English | Beide

Eingeschränkt nach:

Fragen & Antworten | Discontinued Function Generators [Discontinued]

1-25 von 47

Sortieren:

Ergebnisse

Titel/Beschreibung Datum Typ
33120A: Clearing Memory 2002-06-27 FAQ
33120A: EMC Standards Compliance 2002-06-27 FAQ
33120A: Header Files to Include in a C/C++ Program to Control the 33120A w/an GPIB Card 2002-06-27 FAQ
33120A: Manual Availability 2002-06-27 FAQ
33120A: Maximum Output Current 2002-06-27 FAQ
33120A: Noise Function 2002-06-27 FAQ
33120A: Output BNC Connector 2002-06-27 FAQ
33120A: Rackmounting One or More Units 2002-06-27 FAQ
33120A: Replacing the Output Protection Fuse 2002-06-27 FAQ
33120A: Replacing the Power-Line Fuse 2002-06-27 FAQ
33120A: Troubleshooting the RS-232 Connection for Benchlink Arb 2002-08-08 FAQ
34810B/11A/12A/20B BenchLink Products: WinNT® Error 2002-07-29 FAQ
8903B, 8904A Spare Part Numbers and Reference Designators 2002-06-27 FAQ
Adding a dc offset to the output of your function generator
Most function generators have a built-in dc offset that can be added to any waveform. The 33220A's built-in dc offset function can be used with any waveform to generate any combination of amplitude and offset...
2003-10-22 FAQ
Can HyperTerminal be used with Agilent General Purpose Instruments?
HyperTerminal can be used to program most GP instruments using the RS-232 Serial Bus.
2005-06-24 FAQ
Can I control the power-on state of the 33120A?
When power is turned off, the 33120A automatically stores its state in memory location "0".
2002-11-26 FAQ
Can I disable the output without turning the 33120A off?
The 33120A does not have a simple ON/OFF switch for the output. One possible method of producing zero output is to output 0 Volts dc.
2002-09-12 FAQ
Can I program a waveform captured by my oscilloscope into an Agilent arbitrary waveform generator?
Yes. The free IntuiLink Waveform Editor software will download waveform data from Agilent Infiniium, 6000 series, and 54600 series oscilloscopes and send the data to the an Agilent 33120A, 33210A, 33220A, or 33250A generator.
2008-08-29 FAQ
Can I transfer waveform data from the 33120A's arbitrary waveform memory into a PC?
It is not possible to directly transfer waveform data from the 33120A to a PC. While the 33120A is capable of accepting waveform data from a PC, it is not capable of the reverse. One possible workaround involves the use of an oscilloscope.
2002-08-30 FAQ
Can I turn off the audible beep on the Agilent 33120A?
The Agilent 33120A has three forms of audible feedback.
2002-08-30 FAQ
Can you download the values of the X and Y axis of a waveform obtained from the oscilloscope into a function generator to be use as the output?
Yes.
2008-08-29 FAQ
How do I change the line voltage setting on the 33120A?
Instructions for changing the line voltage setting. 1. Remove the power cord.
2002-08-30 FAQ
How do I delete a user-defined arbitrary waveform from memory?
From the remote interface, you can use the commands DATA:DELete specifiying the name of the arbitrary waveform you wish to delete.
2002-11-26 FAQ
How do I generate a DC voltage output from the Agilent 33120A/33220A/33250A?
The Agilent 33120A/33220A/33250A can output DC voltage in the range of -5 V DC to +5 V DC...
2008-08-29 FAQ
How do I generate a dc voltage output from the Agilent 33120A?
The Agilent 33120A can output dc voltage in the range -5 Vdc to +5 Vdc (into a 50-ohm termination).
2002-08-28 FAQ