Paperless Calibration - White Paper
Discusses the benefits of storing calibration records electronically rather than on paper in filing cabinets and explains why having a hard copy of these files is not necessary.

Application Note 2013-01-25

PDF PDF 1.97 MB
Selecting a Calibration Vendor - White Paper
Cost is important but are there any other questions that need to be asked in selecting a calibration supplier?

Application Note 2012-12-11

PDF PDF 1.38 MB
Using a Manufacturer's Specification as a Type B Error Contribution - White Paper
Examines the implications of using a manufacturer's specification in an uncertainty analysis; and how calibration laboratories use uncertainty data in their quality systems and customer-facing documents.

Application Note 2012-12-10

PDF PDF 1.13 MB
Instrument Design Validation and Recommended Calibration Policy - White Paper
Provides background information on the test philosophies and methods used when developing instrument verification and adjustment procedures.

Application Note 2012-11-08

PDF PDF 1.22 MB
Setting and Adjusting Instrument Calibration Intervals
A well-defined calibration interval is one that balances the tradeoffs between the cost and inconvenience of the process and the need to keep test instruments performing within their specifications.

Application Note 2012-10-29

PDF PDF 643 KB
The Six Axes Of Calibration - White Paper
To help demonstrate the variances in the deliverables and value of calibration due to lack of regulation. They have been split into 6 axes. This document discusses each of these axes.

Application Note 2012-10-24

PDF PDF 1.43 MB
The Metrological & Financial Implications of a Clogged Fan Filter - White Paper
This article discussed the implications of having a clogged air filter and addresses solutions to helping in the prevention of clogged air filters.

Application Note 2012-10-24

PDF PDF 1.41 MB
Too Much Calibration? - White Paper
This paper explains the variables at work in the world of calibration - how they can be used to find the elusive balance point between cost and confidence, or "too much" and "not enough" calibration.

Application Note 2012-10-24

PDF PDF 1.23 MB
Connector Pin Recession and its Effect on Network Analyzer Accuracy - White Paper
Outlines an experiment undertaken to assess the impact on the measurement of reflection coefficient when using 3.5 mm connectors.

Application Note 2012-10-24

PDF PDF 762 KB
Fully-Automatic DMM Calibration System - White Paper
Describes a fully-automatic calibration system for digtial multimeters (DMMs), including the uncertainty estimation of DC Voltage measurements.

Application Note 2012-10-14

PDF PDF 2.28 MB
Sensitivity Analysis of One-port Characterized Devices in Vector Network Analyzer Calibrations
Results of a study on the use of characterized devices in microwave vector network analyzer (VNA) calibrations and measurements. A review of the theory of one-port characterized device calibration.

Application Note 2012-10-14

PDF PDF 1.25 MB
Photonics Connector Care: Effects of Damage Connectors and Interfaces in Fiber Optic Measurements
To qualify or predict the effects of damaged fiber optic connectors or optical interfaces, a qualitative assessment can ensure that these connectors are kept in a condition of optimum performance.

Application Note 2012-10-14

PDF PDF 2.28 MB
Calibration of Precision Step Attenuators - White Paper
Automated parallel IF substitution system for precision attenuator calibration which has been in use for over 15 years and presents results of tests made on some very accurate attenuators.

Application Note 2012-10-14

PDF PDF 1.38 MB
Understanding Measurement Risk - White Paper
An intuitive explanation of probability density functions drawing on Monte Carlo simulation to demonstrate the relationship between a device's true values and corresponding measured value.

Application Note 2012-10-09

PDF PDF 749 KB
A Guard-Band Strategy for Managing False-Accept Risk - White Paper
Presents guard-band strategy for managing false-accept risk with only limited knowledge of the a priori probability that a device is in tolerance.

Application Note 2012-10-09

PDF PDF 282 KB
Evaluation of the Performance of a State-of-the-Art Digital Multimeter - White Paper
Describes several methods used to verify the performance of a very accurate automatically calibrated DMM, the HP 3458A.

Application Note 2012-10-02

PDF PDF 478 KB
Attenuation Measurement of Step Attenuators
Describes the T-matrix measurement method for achieving high accuracy in calibrating step attenuators.

Application Note 2012-10-02

PDF PDF 440 KB
An Internet-Enabled Primary Impedance Measurement System - White Paper
iPIMMS allows microwave network analyser users to achieve uncertainties which are equivalent to those of measurementsperformed at the National Physical Laboratory (NPI).

Application Note 2012-09-26

PDF PDF 440 KB
Connector Pin Recession and its Effect on Network Analyzer Accuracy
This article outlines an experiment undertaken to assess the impact on the measurement of reflection coefficient when using 3.5-mm connectors.

Application Note 2012-09-19

PDF PDF 773 KB
Establishing Traceability for Quantities Derived from Multiple Traceable Quantities by Jian Liu
Provides method of developing traceability for measurements (eg. phase noise) that have no SI units.

Application Note 2012-06-15

PDF PDF 1.83 MB
Getting the Calibration You Need
Test equipment calibration is an important part of ensuring the quality and performance of your end products.

Application Note 2012-05-16

Calibration of a Ratio Transformer - White Paper
Describes a calibration technique for decade ratio transformers which is performed by comparison measurement at 1kHz.

Application Note 2011-11-16

PDF PDF 2.30 MB
Revisiting Mismatch Uncertainty with the Rayleigh Distribution by Michael Dobbert & Joe Gorin
This paper examines several important aspects of estimating mismatch uncertainty, which is often a major component of the total uncertainty for RF and microwave measurements.

Application Note 2011-10-06

PDF PDF 1.17 MB
Business Considerations of Equipment Refresh in a Calibration Laboratory by Richard Ogg
Calibration laboratories operate in a world of constant change, and this is never more evident than in the products that are requested to be calibrated.

Application Note 2011-10-05

Isolating Frequency Measurement Error and Sourcing Frequency by Robert Leiby
When performing a calibration, the risk of incorrectly declaring a device as in-tolerance (false-accept risk) is dependent upon several factors such as the specified tolerance limit and guard band.

Application Note 2011-10-05

PDF PDF 3.42 MB