Technical Support
Calibration Services & Repair
Refine the List
By Type of Content
- Specifications (10)
- Application Notes (29)
- Brochures & Competitive Overviews (18)
- Demos (2)
- Articles & Case Studies (2)
Par catégorie de produit
- Instrument Calibration and Repair: Single-Source Solutions (6)
- Instrument Calibration and Repair: Service Plans (3)
- Instrument Calibration and Repair: Single-Event Service (3)
- Learn about Test Equipment Calibration (10)
- Learn about Test Equipment Repair (12)
- Learn about Agilent Infoline Services (3)
- Learn about Metrology & Calibration Standards (31)
- Agilent Assurance Plans (1)
26-50 of 61
|
Understanding Measurement Risk - White Paper
An intuitive explanation of probability density functions drawing on Monte Carlo simulation to demonstrate the relationship between a device's true values and corresponding measured value.
Application Note 2012-10-09 |
|
|
A Guard-Band Strategy for Managing False-Accept Risk - White Paper
Presents guard-band strategy for managing false-accept risk with only limited knowledge of the a priori probability that a device is in tolerance.
Application Note 2012-10-09 |
|
|
Attenuation Measurement of Step Attenuators
Describes the T-matrix measurement method for achieving high accuracy in calibrating step attenuators.
Application Note 2012-10-02 |
|
|
Evaluation of the Performance of a State-of-the-Art Digital Multimeter - White Paper
Describes several methods used to verify the performance of a very accurate automatically calibrated DMM, the HP 3458A.
Application Note 2012-10-02 |
|
|
An Internet-Enabled Primary Impedance Measurement System - White Paper
iPIMMS allows microwave network analyser users to achieve uncertainties which are equivalent to those of measurementsperformed at the National Physical Laboratory (NPI).
Application Note 2012-09-26 |
|
|
Connector Pin Recession and its Effect on Network Analyzer Accuracy
This article outlines an experiment undertaken to assess the impact on the measurement of reflection coefficient when using 3.5-mm connectors.
Application Note 2012-09-19 |
|
|
Establishing Traceability for Quantities Derived from Multiple Traceable Quantities by Jian Liu
Provides method of developing traceability for measurements (eg. phase noise) that have no SI units.
Application Note 2012-06-15 |
|
|
Getting the Calibration You Need
Test equipment calibration is an important part of ensuring the quality and performance of your end products.
Application Note 2012-05-16 |
|
|
Thales Nederland Reaps the Benefits of Agilent Onsite Calibration
Thales Nederland experienced product shipment delays and cost overruns due to long turn around times for calibration. Agilent solved their challenge with the solution of Onsite Calibration.
Case Study 2012-03-09 |
|
|
What is Covered by Warranty?
Agilent warrants Agilent hardware products against defects in materials and workmanship and that Agilent hardware products conform to Agilent published specifications.
Technical Overview 2012-02-29 |
|
|
Tips for Preventing Damage to Spectrum Analyzer
Committed to your success throughout your equipment's lifetime
Data Sheet 2012-02-28 |
|
|
Calibration of a Ratio Transformer - White Paper
Describes a calibration technique for decade ratio transformers which is performed by comparison measurement at 1kHz.
Application Note 2011-11-16 |
|
|
Managing Your Test Equipment's Cost of Ownership - What is Your Plan?
This brochure describes the value of Agilent Advantage Services. It's not just fast repairs or calibration stickers When you work with Agilent Advantage Services, it's a partnership.
Brochure 2011-10-12 |
|
|
Revisiting Mismatch Uncertainty with the Rayleigh Distribution by Michael Dobbert & Joe Gorin
This paper examines several important aspects of estimating mismatch uncertainty, which is often a major component of the total uncertainty for RF and microwave measurements.
Application Note 2011-10-06 |
|
|
Isolating Frequency Measurement Error and Sourcing Frequency by Robert Leiby
When performing a calibration, the risk of incorrectly declaring a device as in-tolerance (false-accept risk) is dependent upon several factors such as the specified tolerance limit and guard band.
Application Note 2011-10-05 |
|
|
Business Considerations of Equipment Refresh in a Calibration Laboratory by Richard Ogg
Calibration laboratories operate in a world of constant change, and this is never more evident than in the products that are requested to be calibrated.
Application Note 2011-10-05 |
|
|
Calibration Process Innovation Using Non-Required Guard Banded Testing by Richard Ogg
Calibration services vary as to how to set the acceptance limits compared to the required tolerance. Using a guard band to reduce the acceptance limit will increase the confidence in the calibration.
Application Note 2011-09-30 |
|
|
Managing Your Test Equipment’s Total Cost of Ownership
It’s not just fast repairs or calibration stickers. When you work with Agilent Advantage Services, it’s a partnership.
Brochure 2011-09-30 |
|
|
Guardbanding
Ensure the highest level of measurement confidence.
Brochure 2011-08-04 |
|
|
Uncertainty Analysis for Uncorrelated Input Quantities by Alberto Campillo
Reference information for those who develop their own measurement uncertainties
Application Note 2011-08-01 |
|
|
N7800A Calibration and Adjustment Software - Data Sheet
Agilent N7800A calibration and adjustment software is available for customers who have the necessary equipment, facility, manpower and skill to calibrate test equipment.
Data Sheet 2011-05-20 |
|
|
Tips for Preventing Damage to 42481A and LCR Meter
Agilent Model 42841A and LCR Meter
Data Sheet 2011-04-06 |
|
|
Tips for Preventing Damage to Digital Multimeter
Popular Agilent models: 3458A, 34401A
Data Sheet 2011-04-01 |
|
|
Tips for Preventing Damage to Signal Generator
Popular Agilent models: E443xB, E4438C, E82x7D
Data Sheet 2011-04-01 |
|
|
Tips for Preventing Damage to DCA, OSA TDR Analyzer
Popular Agilent models: 54754A, 86100C
Data Sheet 2011-04-01 |
