Measuring Dielectric Properties using Agilent's Materials Measurement Solutions - Brochure
Quick guide for Agilent materials measurement solutions that can characterize the material under test by measuring dielectric properties such as permittivity and permeability.

Brochure 2013-04-05

PDF PDF 478 KB
Correlating Impedance Measurements Among Different Types of Measurement Instruments (PN 4291-4)
The 4291B is the advanced impedance analyzer which has the capability to make accurate measurements. This document discusses the data correlation between the 4291B and older instrument.

Application Note 2012-04-27

PDF PDF 51 KB
16197A Bottom Electrode SMD Test Fixture Operation and Service Manual
This manual contains operation and service information for Agilent 16197A Bottom Electrode SMD Test Fixture.

User Manual 2011-09-01

PDF PDF 2 MB
16201A Teminal Adapter Operation and Service Manual
Supplemental information for the the operation and servicing of the 16201A terminal adapter.

Operation Manual 2010-12-20

PDF PDF 333 KB
Impedance Measurement Handbook
Impedance measurements basics using Agilent Technologies' LCR meters and impedance analysers.

Application Note 2009-06-17

Accessories Selection Guide For Impedance Measurements
Impedance test fixtures that can be used with LCR meters, Resistance Meters, Capacitance Meters, Impedance Analyzers, and Combination Analyzers

Selection Guide 2008-12-17

New Technologies for Accurate Impedance Measurement (40Hz to 110MHz)
Auto-balancing bridge method is the best technique to make an accurate impedance measurement in LF frequency. The recent technical innovation successfully expanded its upper frequency limitation from 40MHz to 110MHz. This Product Note discusses how its made and other new technologies included in...

Application Note 2008-11-20

Measurement of Capacitance Characteristics of Liquid Crystal Cell (AN 369-7)
This application note describes how to take best advantage of the 4284A's powerful features when measurin gcapacitance while varying an AC signal voltage applied tothe liquid crystal material under test.

Application Note 2008-11-20

Achieving Fast Design Cycle Time
This application note describes how fast cycle time is achieved using the impedance analyzer such as the E4991A and 4294A with the Electronic Design Automation (EDA) tools.

Application Note 2008-11-13

Solutions for Measuring Permittivity and Permeability w/LCR Meters & Impedance Analyzers (AN 1369-1)
This presents the technologies and methods for measuring permittivity and permeability. Primarily on methods that employ the impedance measurement technology.

Application Note 2008-10-28

16334A Test Fixture Operation and Service Manual
This manual describes basic information needed to use the 16334A. It provides a product overview, specifications, typical characteristics, operation, and service information.

User Manual 2008-09-01

PDF PDF 559 KB
Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer (AN 346-2)
This application note describes the difference between a balanced circuit and an unbalanced circuit, and also explains how to make an unbalanced circuit measurement by the unbalanced instrument step by step.

Application Note 2008-04-10

PDF PDF 116 KB
Contact Resistance and Insulation Resistance Measurements of Electromechanical Components (AN1305-1)
This application note describes the contact resistance and insulation resistance measurement of mechanical components.

Application Note 2008-04-03

PDF PDF 119 KB
16196A/B/C/D Correlating RF Impedance Measurements When Using SMD Test Fixtures
This Product Note explains that the ability to verify the correlation of impedance measurement results is dependent on the variety of factors.

Application Note 2007-03-06

16092A Operation Manual for reference
Drawn out from Agilent 4191A Operation and Service Manual

User Manual 2005-07-27

PDF PDF 1.74 MB
16196A/B/C/D Parallel Electrode SMD Test Fixture Operation and Service Manual
This manual describes basic information needed to use the 16196A/B/C/D. It provides a installation guide product overview operation user maintenance specifications supplemental performance characteristics and service information.

User Manual 2005-06-01

16380V Option 001 10 uF Capacitance Standard Upgrade Kit Upgrade Manual

User Manual 2003-06-01

PDF PDF 458 KB
42100A Four Terminal Pair Resistor Set Operation & Service Manual
42100A Four Terminal Pair Resistor Set Operation and Service Manual

Operation Manual 2003-05-01

PDF PDF 800 KB
16118A Tweezer Test Fixture Operation and Service Manual
16118A Tweezer Test Fixture Operation and Service Manual

User Manual 2002-05-14

16048A Test Lead Operation and Service Manual
16048A Test Lead Operation and Service Manual

User Manual 2002-02-24

16047E Test Fixture , 40 Hz to 110MHz Operation and Service Manual
16047E Test Fixture , 40 Hz to 110MHz Operation and Service Manual

User Manual 2002-02-24

16192A Parallel Electrode SMD Test Fixture Operation and Service Manual
16192A Parallel Electrode SMD Test Fixture Operation and Service Manual

User Manual 2001-11-21

16194A High Temperature Component Fixture Operation and Service Manual
16194A High Temperature Component Fixture Operation and Service Manual

User Manual 2001-11-15

16453A Dielectric Material Test Fixture Specification and Service Manual
16453A Dielectric Material Test Fixture Specification and Service Manual

User Manual 2001-11-15

16089A,B,C Kelvin Clip Leads 16089D Alligator Clip Leads Operation and Service Manual
16089A,B,C Kelvin Clip Leads 16089D Alligator Clip Leads Operation and Service Manual

Operation Manual 2001-11-15