How can I set up Power-on State of the B2901/02/11/12A?
It is possible to store the desired instrument condition as Power-on State. Click the above link for details.

FAQ 2012-11-21

Can I use the triaxial cable with B2900A?
Yes. You can use the triaxial cable by using the N1294A adaptor.

FAQ 2012-11-20

The password is required to access the instrument.
The password is required to access the instrument compliant with the LXI specification. Click the above link for details.

FAQ 2012-10-09

The channel 2 in the B2902A or B2912A doesn't receive any SCPI commands.
The instrument may be configured to use the conventional command set. Click the above link for details.

FAQ 2012-10-09

I cannot store the channel 2 measurement condition to USB memory stick, why not?
The instrument may be configured to use the conventional command set. Click the above link for details.

FAQ 2012-10-09

Does the B2901/02/11/12A have any search function?
No, the B2901/02/11/12A doesn't have any search function which the analyzers such as the B1500A have.

FAQ 2012-10-09

How to determine the frequency for Sin function of Quick IV List Sweep?
Frequency = 1 / ( (360 [degree] / X Step [degree]) * Trigger Period )

FAQ 2012-10-09

How Do I Find My Host Information?
The Host ID is the model and/or serial number of the product, both of which can be found on the serial number label on the back of the instrument.

FAQ 2012-06-14

How many capacitance measurement units (MFCMUs) can be installed in the B1500A?
Only one MFCMU can be installed in a B1500A mainframe.

FAQ 2012-06-07

How can I configure to output continuous arbitrary waveform?
Click the above link for details.

FAQ 2012-03-26

How can I find the remote control command setting of the B2901/02/11/12A?
You can find the remote control command setting by pressing the System>SCPI functuion keys. Click the above link for details.

FAQ 2012-02-01

How can I find the power-on state setting of the B2901/02/11/12A?
You can find the power-on state setting on the System Start-up dialog box. Click the above link for details.

FAQ 2012-02-01

How can I configure Trigger Output Signals with the B2901/02/11/12A?
Click the above link for details.

FAQ 2012-02-01

How to configure the time constant of the output filter with the B2901/02/11/12A?
The time constant of the output filter can be configured on the Output Filter dialog box. Click the above link for details.

FAQ 2012-02-01

How can I select the default command set as the remote control command set of the B2901/02/11/12A?
You can configure the unit to use the default command set by pressing the System>SCPI functuion keys. Click the above link for details.

FAQ 2012-02-01

How can I find the power-on program setting of the B2901/02/11/12A?
You can find the power-on program setting on the System Start-up dialog box. Click the above link for details.

FAQ 2012-02-01

[B1542A] Do not use a base line voltage of gate pulse exceeding +/- 3V range
Do not use a base line voltage of gate pulse lower than -3 V or larger than +3 V to avoid a potential risk of damage on the pulse divider used in the gate cabling system.

FAQ 2012-01-11

How can I set the remote control command set of the Agilent B2901/02/11/12A?
Please take the actions described in the link above to set the remote control command set.

FAQ 2011-12-01

How to configure to output continuous pulses with the B2901/02/11/12A?
It is required to set the ARM count to INFINIY to source continuous pulses. Click the above link for details.

FAQ 2011-12-01

I cannot see the result data more than 2500 points in Measure Result Dialogue.
The instrument may be configured to use the conventional command set. Click the above link for details.

FAQ 2011-12-01

Is there any way to reset only the specified channel of the B2902/12A?
No, there is no way to reset only the specified channel.

FAQ 2011-12-01

How can I realize an accurate low current measurement with the B2901/02/11/12A?
It is necessary to take care of the folloing points in order to make it. Click the above link for details.

FAQ 2011-12-01

[B1542A] Dose 81130A supported by the B1542A Ultra Narrow Pulsed IV solution?
No.

FAQ 2011-11-17

[B1542A] What is the maximaum volatge range of gate pulse?
The maximum voltage rage of gate pulse supported by the B1542A Ultra Narrow Pulsed IV solution is -Pulse top: -4.5 V to + 4.5V, -Pulse base::-3 V to +3 V, -Amplitude: 4.5 V or less.

FAQ 2011-11-17

What is required to run EasyEXPERT 3.2 to 4.11?
The software requirements of EasyEXPERT 3.2 to 4.11 are as follows.

FAQ 2011-10-26