Is there any special setting that I need to do in Agilent VEE before using the U2300A or U2500A DAQ with it?
Yes. In fact it is the most important thing you need to set before using the DAQ with Agilent VEE. As most instruments uses MSB byte ordering, DAQ...

FAQ 2009-12-15

How can I control the 34980A internal DMM using the IVI-C Dmm class in cooperation with the 34980A IVI driver?
Please download from the link for the document on how to control the internal DMM using IVI-C Dmm class in cooperation with the 34980A IVI driver.

FAQ 2009-12-02

Can strain gauges be measured with the Agilent 34970A?
The 34970A can measure strain gauges using 4-wire ohms measurements and return the strain value using the math formula Mx+B.

FAQ 2009-11-18

VEE 9.0 has SCPI completion. How do I make my own SCPI command built-in with VEE?
Please refer to the attached Microsoft Word document for a step by step explanation...

FAQ 2009-11-12

I've written my own text format for SCPI in *.txt. How do I use these for SCPI completion within VEE 9.0. What tool should I use?
You can use the tool found within Agilent.com. Just search using the keyword "Agilent VEE SCPI...

FAQ 2009-11-12

Why do I not see all the data points on my graph tab?
When viewing your readings from the Graph Tab, some times not all of your data is displayed.

FAQ 2009-11-05

What is the main difference between the digital output (DO) of the U2100A, U2600A, U2300A and U2500A?
The DO port of U2100A and U2600A requires external power supply to be pumped into the port...

FAQ 2009-10-20

Where to find the USB modular scopes IVI-COM programming guide?
download the programming guide.

FAQ 2009-09-29

Why am I not able to update my E5810A firmware via Agilent FTP at ftp://ftp.agilent.com/pub/e5810/ ?
Firmware revision A.01.07 and above are able to update via ftp

FAQ 2009-09-29

How do I know what is the best sampling rate to use for my measurement?
Typically if you follow Nyquist theory, your sampling rate should be 2x the highest frequency of the incoming signal that you are measuring. However, we recommend that you use 5x...

FAQ 2009-09-29

How much of data points from my data acquired can I save into one file?
What we observed is that if you log your file into *.csv file, the most no. of points you will be capturing is 65536 points. However, if you are saving into *.txt file, it will depend on the type of...

FAQ 2009-09-29

Can U2651A work with 3.3V input signal or not?
As long as there is a potential exceeding 10V and less than 24V between DIin and DIcom, the digital input should be able to observe the incoming signal as logic high...

FAQ 2009-09-29

How Do I Measure Resistance With A 3-Wire Device?
If you are using a 3-wire device (ie. 3-wire RTD), to measure it accurately, you have to first measure the resistance of R1+R2+Rm then subtract the resistance you measured of R2+R3.

FAQ 2009-09-28

IO Libraries Suite: What has changed in IO Libraries Suite 16.0?
PXI/PXIe support, IVI USBTMC driver, industry standards tracking, product enhancement and bugfixes

FAQ 2009-09-01

IO Libraries Suite: What is the VISA 64 Conflict Manager?
Agilent's VISA 64 Conflict Manager allows you to view and modify the VISA implementation settings for all 64-bit VISA implementations installed on your system...

FAQ 2009-08-25

IO Libraries Suite: Can software written from other vendors specific to their devices that utilize NI-488.2 as an I/O Library work with an Agilent ...
Yes, it is possible with Agilent IO Library version 14.1 and greater.

FAQ 2009-08-25

IO Libraries Suite: What is the VISA 32 Open Report?
The VISA 32 Open Report provides a quick "snapshot" of information about all of the instruments configured on your PC.

FAQ 2009-08-25

IO Libraries Suite: How do I install the E8491 driver when I upgrade from a previous release to IO Libraries Suite 15.1?
Follow these steps...

FAQ 2009-08-25

IO Libraries Suite: Is there any other software that needs to be installed when I am using an application that utilizes NI-488.2 and Agilent IO Lib...
It depends if there is third party connectivity hardware or software installed.

FAQ 2009-08-25

IO Libraries Suite: Why does my LAN instrument not show up in the LAN discovery tool?
Your instruments may be configured incorrectly, on a different subnet, or connected to an E5810A.

FAQ 2009-08-25

IO Libraries Suite: Why does T&M Toolkit’s IO Monitor quit working when I install IO Libraries Suite 15.0, or later?
Agilent IO Libraries Suite 15.0, and later, includes a new, updated version of the IO Monitor tool. Because of this, the older IO Monitor shipped with T&M Toolkit will no longer function.

FAQ 2009-08-25

How do I avoid getting “Out of memory” exception errors when using the BenchLink DataLogger software?
Do not leave the Quick Graph tab active in the BenchLink DataLogger...

FAQ 2009-08-19

How do I avoid getting "The memory could not be "read"" error upon closing the software?
It’s most likely this issue is caused by a bad memory...

FAQ 2009-08-19

How to speed up my computer processing time while running the BenchLink DataLogger software continuously for a long period of time?
Do not leave the Quick Graph tab active in the BenchLink DataLogger...

FAQ 2009-08-19

How can I remotely connect to all my USB DAQ devices, Digital IOs, and card cage?
Please make sure that your remote PC (which is connected to all your USB instruments) is connected to the same network as yourself. However, your remote PC cannot be connected...

FAQ 2009-08-06