Hable con un experto

Technical Support

Electronic Measurement

Find by Product Model Number: Examples: 34401A, E4440A

1-25 of 27

Sort:
Evaluating Oscilloscope Fundamentals - Application Note
We will discuss oscilloscope applications and give you an overview of basic measurements and performance characteristics.

Application Note 2013-03-06

Ten things to Consider when Selecting your Next Oscilloscope - Application Note
You rely on your oscilloscope every day, so selecting the right one to meet your needs is an important task. Comparing specs and features of scopes made by different manufacturers can be time-consuming and confusing. The concepts outlined here are intended to speed your selection process and help you avoid some common pitfalls. No matter who makes the scopes you are considering, carefully analyzing each one in relation to the 10 issues discussed here will help you evaluate the instruments objectively.

Application Note 2012-05-15

Practical Temperature Measurements (AN-290)
The purpose of this application note is to explore the more common temperature measurement techniques, and introduce procedures for improving their accuracy.

Application Note 2012-01-26

PDF PDF 1.29 MB
Creating, Editing, Transferring Arbitrary Waveforms with Agilent U2761A Function Generator
This application note explores how a complex arbitrary waveform is created by using software, importing, reusing existing waveform files and easily programs your instrument with the free Command Logger and Code Converter functions.

Application Note 2009-12-11

Solar Cell and Module Testing
This application note describes how to decrease costs and increase flexibility for solar cell and module testing with Agilent products and solutions.

Application Note 2009-12-07

Creating Arbitrary Waveforms in the U2300A Series and U2500A Series Data Acquisition Devices
This application note covers the inner workings of how waveforms and arbitrary waveforms are formed.

Application Note 2009-08-01

Using the U2331A USB DAQ in the construction industry
The device can be used to measure various types of parameters in the construction industry.

Application Note 2009-04-06

PDF PDF 229 KB
DC-to-DC Regulator Auto Evaluation Test with the U2351A
The Agilent U2351A data acquisition (DAQ) is used as an automatic DC voltage regulator and to induce voltage into the electronics system thereby causing an amount of under voltage or over voltage stress to the device under test (DUT).

Application Note 2009-02-04

PDF PDF 270 KB
DVD Player Manufacturing Test Using Agilent Modular Instruments
Audio and video testing of modern digital video disc (DVD) player using Agilent’s USB modular oscilloscopes and USB modular switch matrix.

Application Note 2008-09-15

10 Hints for Getting More from Your Function Generator (AN 1497)
The 10 hints in this application note will help you take advantage of the features of your function/arbitrary waveform generator so you can get your job done more easily.

Application Note 2008-07-16

Automotive Power Window Regulator Testing - Application Note
Automotive power window regulator tests require the use of accurate data acquisition devices, as they cover a wide range of parameters such as window movement, acceleration of the window movement in both directions, maximum range of movement, torque exerted at the start, the end stall torque, and motor load characteristics.

Application Note 2008-06-30

PDF PDF 280 KB
Small Engine Dynamometer Testing - Application Note
Performing Dynamometer Testing on Combustion Engines

Application Note 2008-06-01

PDF PDF 443 KB
Testing Electromagnetic Compatibility of Remote Keyless Entry Modules in Automotive Applications
One of the most widely used electronic systems is remote keyless entry (RKE). Many manufacturers are expanding the capabilities of the RKE modules being used in the latest automobiles. With increased module functionality, there is also a need for increased test coverage because an RKE module may be used to perform multiple tasks, from unlocking car doors to remotely starting a car’s engine.

Application Note 2008-04-01

PDF PDF 110 KB
Creating a Small, Low-cost RF Switching System using U2121A based solution
Creating a Small, Low-cost RF Switching System using U2121A based solution. This digital I/O module provides a cost-effective alternative for small test systems.

Application Note 2008-03-18

PDF PDF 271 KB
Best of 8 Hints for Making Better Oscilloscopes Measurements
Agilent engineers sharing ideas of how to use the equipment they design

Application Note 2008-03-17

PDF PDF 320 KB
Automated Handler Machine for Test System Using Agilent U2100A DIO
This application note describes how the Agilent U2100A DIO is used for machine automation.

Application Note 2007-11-14

PDF PDF 342 KB
PMU Troubleshooting Using U2531A Simultaneous Data Acquisition
This application note describes how PMU troubleshooting can be performed using the U2500A Series Simultaneous Sampling DAQ.

Application Note 2007-11-14

PDF PDF 158 KB
10 Practical Tips You Need to Know about Your Power Products - Application Note
Learn ten simple ways to improve your testing capabilities with your power supplies and electronic loads.

Application Note 2007-09-21

Strain Measurement Application Using U2300A Series with Agilent VEE Pro - Application Note
This application note describes how users can make strain and vibration measurements using the Agilent USB DAQ for reliability and strength characterization of concrete and metal structures.

Application Note 2007-05-18

PDF PDF 208 KB
Tips for Making Better AC, True RMS Measurements
Learn to make better ac measurements. Learn about ac signals and how to take advantage of features built-in to your multimeter.

Application Note 2004-05-19

How to capture, save, and reproduce arbitrary waveforms
This 6-page application note provides techniques for capturing, saving and reproducing current waveforms and profiles.

Application Note 2003-11-21

9 Tips for Making Better Resistance Measurements
Nine tips for making better resistance measurements with your Agilent voltmeter.

Application Note 2003-11-18

Using a Function/Arbitrary Waveform Generator to Generate Pulses (AN 1437)
A function generator can be a low cost alternative for creating simple pulses. This application note describes several techniques for creating pulses using a function generator.

Application Note 2002-12-13

8 More Hints for Making Better Scopes Measurements
This Application Note contains a variety of hints to help you understand and improve your use of oscilloscopes. It includes the following 8 hints: 1. Don't forget to check that probe 2. A quick, easy way to troubleshoot mixed hardware/software prototypes 3. Using scopes to measure noisy signals 4...

Application Note 1999-12-01

PDF PDF 840 KB
DC Power Supply Handbook (AN 90B)
This Application Note is for information only. Agilent no longer sells or supports these products.

Application Note 1978-01-01

PDF PDF 5 MB

1 2 Next