What is the maximum total length of the RJ45 control cable for connecting multiple 34945EXTs?
The maximum total length of the RJ45 control cables is 140 feet.
FAQ 2013-05-06 |
|
|
How do I view the 3D models that come with the L4490A/L4491A?
The L4490A/L4491A comes with .easm, .igs and .stp files that can be imported into your modeling application.
FAQ 2013-03-13 |
|
|
Where do I get Java to display the 34980A web interface?
The Java Virtual Machine code is needed to run the Agilent 34980A web page features. A free download of the Java Virtual Machine (JVM) can be obtained by going to the following web site.
FAQ 2012-12-17 |
|
|
How do you clear the 34980A multifunction switch/measure mainframe and modules, L44xxA series LXI switch and control instruments memories?
Please refer to the documents for a comprehensive listing of memory installed into these products.
FAQ 2012-12-12 |
|
|
What components are included in the Agilent Y1157A cable kit?
The Agilent Y1157A is a 9 pin DSUB to 10 pin IDC cable kit for the Y1150A, Y1152A and / or the Y1154A distribution boards. (See Chart)
FAQ 2012-10-15 |
|
|
What components are included in the Agilent Y1159A cable kit?
The Agilent Y1159A is a 16 pin IDC to 16 pin IDC cable kit for the Y1150A, Y1151A, Y1152A, Y1153A, Y1154A and / or the Y1155A distribution boards. (See Chart)
FAQ 2012-10-15 |
|
|
What components are included in the Agilent Y1158A cable kit?
The Agilent Y1158A is a 10 pin IDC to 10 pin IDC or 10 pin IDC to 14 pin IDC cable kit for the Y1153A and / or the Y1154A distribution boards. (See Chart)
FAQ 2012-10-15 |
|
|
Why don’t my Agilent PXI modules show up in National Instruments-Measurement & Automation Explorer (NI-MAX)?
NI-MAX is a tool provided by National Instruments (NI) for managing NI hardware and software...
FAQ 2012-09-20 |
|
|
What can I do if I fail to establish hardware connection after successfully installing Agilent USB modular instrument driver on a Win7 environment?
If you encountered the event mentioned above, follow the installation best practices steps below.
FAQ 2012-07-25 |
|
|
What can I do if the Agilent USB Modular Instrument driver installations failed to complete installation on a Windows 7 environment?
If you encountered the event mentioned above, follow the installation best practices steps below.
FAQ 2012-07-25 |
|
|
Why do I get +943 "Remote module topology change" and +935 "Overcurrent detected" errors?
During operation, exceeding the 34945A, L4445A, or L4490A/L4491A internal switch drive power supply current specification of "100 mA continuous + 200 mA (15 ms pulse, 25% duty cycle)" can cause overcurrent conditions within the instrument’s power ...
FAQ 2012-07-17 |
|
|
How do I bypass 34923A protection resistors?
To bypass the 100 ohm resistors on the 34923A card, connect the jumpers according to the pictures below.
FAQ 2012-07-16 |
|
|
How many Agilent 34970A data acquisition units can be connected to a single PC at a time?
Only one Agilent 34970A can be connected for each RS-232 port on the PC. A GP-IB cable can be used to connect up to 15 units if the GP-IB cable is being referenced by the VEE software. The Benchlink Data Logger 3 software can support up to 4 units...
FAQ 2012-01-25 |
|
|
Agilent Driver Migration Tool
FAQ 2012-01-20 |
|
|
What are the differences between Agilent M918xA DMMs and Signametrics SMX2060 Series DMMs?
FAQ 2012-01-01 |
|
|
The Agilent 8761B SPDT Coaxial Switches are not listed in the "Agilent 34945A, L4445A and L4490A/L4491A Configuration Guide". Why?
Due to the 8761B’s internal design the RF path selection is achieved via DC polarity reversal across the coil control terminals. The Agilent 34945A, L4445A and L4490A/L4491A Control Units do not provide a polarity reversal mode. Thus the 8761B cannot be controlled by the 34945A, L4445A and L4490A/L4491A Control Units.
FAQ 2011-12-19 |
|
|
Why the latest USB Modular DAQ hardware driver doesn't work for my Win 7 64bit?
It requires a separate hardware driver installer for USB Modular DAQ for Win 7 64bit
FAQ 2011-09-12 |
|
|
How do you trigger a signal using the M9182A and M9183A PXI DMMs?
There are several ways to trigger and measure a signal. Advanced triggering capabilities available with the M9182A/83A PXI DMMs allow you to trigger and measure multiple samples without losing accuracy or resolution (multi-sample mode)...
FAQ 2011-09-02 |
|
|
How do I erase the memory of the M9181A, M9182A, M9183A PXI Digital Multimeters?
This document describes the method for clearing the memory to default values, or to an empty condition.
FAQ 2011-08-30 |
|
|
Can the same type modules be paired together to open/close corresponding switches at the same time?
Yes, here are a couple of examples:
The N2280A (Quad 1x2) can be configured as two wire 1x2s using the "card pair" command.
The N2281A (Dual 1x4) can be configured as 2x4s using the "card pair" command.
FAQ 2011-07-27 |
|
|
How do you clear the M91xxA memory?
FAQ 2011-06-22 |
|
|
How to Synchronize Waveforms from Multiple 34951A Channels
FAQ 2011-04-29 |
|
|
How do I get information (ie. Vendor ID, Device ID, Subsystem ID, Subsystem Vendor Id) on my specific device?
Open Windows Device Manager...
FAQ 2011-04-25 |
|
|
How to Connect Agilent 849xG/H OPT 016 Step Attenuators to Y1153A
FAQ 2011-04-15 |
|
|
What should I do when I get the “Unable to open instrument” error while communicating with PXIe modules on a non-English OS system?
This error is known to display when the old Agilent IO Libraries 16.0 is run on a non-English OS system and trying to communicate with PXIe modules...
FAQ 2011-03-16 |
|