How do I set channel limits?
On the “Configure Scan Lists” tab, after configuring a channel's measurement function, you can set limits by clicking in the channel's Limit Type column.

FAQ 2010-05-05

Is there a pictorial or tabular representation available for my scan lists, events, Action Scripts, and notifications?
Yes.

FAQ 2010-05-05

How can I move a complete configuration from one PC to another?
You can do this by creating a package, move the package to the new PC then read the package in.

FAQ 2010-05-05

Can I mix 34980As and 34970As in the same configuration?
You can have a combination of one 34980A and one or two 34970As in a configuration.

FAQ 2010-05-05

Can I send an email following a scan or on some event?
Yes. You can use a notification to execute an external program or batch file in response to an event.

FAQ 2010-05-05

How is licensing implemented for Data Logger Pro?
To run the Data Logger Pro software after the evaluation period, you must have a license for each PC using the software.

FAQ 2010-05-05

Can I print the graph data to a printer?
Yes. On a graph tab, click the Preferences... button and select Show Graph Menu Bar.

FAQ 2010-05-05

Can I reduce data while scanning?
No. All scanned data is saved in the datalog.

FAQ 2010-05-05

How can I Locate Exported Data on the Hard Disk?
You can control where files are stored using either the automatic or manual methods discussed above.

FAQ 2010-05-05

Are there separate licenses for 34970A and 34980A instruments?
Yes. Each instrument uses a specific Data Logger Pro product number.

FAQ 2010-05-05

I'm only interested in some of the scanned data. Can I automatically reduce the data during export?
Yes. You can also reduce data when graphing. See “Data Reduction” in the Help menu for details.

FAQ 2010-05-05

Can I upload instrument configurations and scanned data from an instrument?
Yes. To upload the instrument configuration and, if available, measured data, click Configuration > New by Upload...

FAQ 2010-05-05

I do not understand how to use a particular MATLAB function. Who can help me?
Contact The MathWorks

FAQ 2010-05-03

Can I use the National Instruments 34970A LabView Driver and Examples with the 34972A?
Yes, there is a new Labview driver that supports both the 34972A and the 34970A...

FAQ 2010-04-16

Why USB modular instruments (U272XA, U2741A, U2751A and U2761A) is not detectable by E5813A?
PC is failed to enumerate the USB modular instrument.

FAQ 2010-04-09

Transferring Data and Configurations to a new version or to a new computer
Moving between computers with same version or moving configurations and data to a new version on the same computer:

FAQ 2010-03-30

Is U2722A compatible with E5813A?
No

FAQ 2010-03-22

Is U2741A compatible with E5813A?
U2741A is not compatible with E5813A.

FAQ 2010-03-22

Is the USB connection of U2300A,U2500A and U2600A optically coupled?
No. It is not.

FAQ 2010-03-22

Is U2751A compatible with E5813A?
U2751A is not compatible with E5813A.

FAQ 2010-03-22

Is U2761A compatible with E5813A?
U2761A is not compatible with E5813A

FAQ 2010-03-22

Is U2723A compatible with E5813A?
No

FAQ 2010-03-22

Are there any programming commands for the U2741A USB Modular Digital Multimeter?
Yes, U2741A supports both SCPI command and IVI-driver for remote instrument control.

FAQ 2010-02-01

What type of internal memory is installed into the 34972A LXI Data Acquisition Switch Unit?
The Agilent 34972A LXI Data Acquisition Switch Unit utilizes Windows CE...

FAQ 2010-01-25

What does ENOB of 13.3 bit means in the specification sheet?
ENOB = (SINAD-1.76)/6.02 Overall Accuracy = ENOB (Effective Number of Bits)....

FAQ 2009-12-15