Can scanned data be exported? If so, what formats are supported?
Yes. Data can be exported to files in either ASCII or Unicode format.

FAQ 2010-05-05

Is there a pictorial or tabular representation available for my scan lists, events, Action Scripts, and notifications?
Yes.

FAQ 2010-05-05

How do I control instruments using SCPI commands?
You can use Action Scripts and SCPI commands to control any instrument connected to the PC.

FAQ 2010-05-05

What is the Base scan list?
The default scan list is named Scan List A and is the Base scan list.

FAQ 2010-05-05

How many instruments can I have in a configuration?
You can have up to two 34980As or four 34970As in a configuration

FAQ 2010-05-05

How can I Locate Exported Data on the Hard Disk?
You can control where files are stored using either the automatic or manual methods discussed above.

FAQ 2010-05-05

Can I print the graph data to a printer?
Yes. On a graph tab, click the Preferences... button and select Show Graph Menu Bar.

FAQ 2010-05-05

Can I run two scan lists at the same time (in parallel)?
No. Scan lists can only be run sequentially

FAQ 2010-05-05

Can I start a scan and then close Data Logger Pro and continue scanning?
Yes. However, there are some limitations.

FAQ 2010-05-05

I'm only interested in some of the scanned data. Can I automatically reduce the data during export?
Yes. You can also reduce data when graphing. See “Data Reduction” in the Help menu for details.

FAQ 2010-05-05

Where can I export the data?
You can save data to files on any disk drive or storage media connected to your PC.

FAQ 2010-05-05

How are multiple scan lists graphed?
The starting point for each scan list is indicated by a vertical bar on the graph and the label Started.

FAQ 2010-05-05

Can I rename an instrument instead of using the default Instr1, Instr2... naming convention?
Yes. Click on InstrN in the Name column of the “Configure Instruments” tab and enter a new instrument name.

FAQ 2010-05-05

Can I be scanning and run an Action Script at the same time (in parallel)?
No. Scan lists and Action Scripts are executed sequentially

FAQ 2010-05-05

Can I filter the data shown on a graph?
Yes. On a graph tab, click the Channels... button to select which channels to graph and/or to show only certain measurement functions.

FAQ 2010-05-05

Can I have different channels in different scan lists?
You can have different enabled channels in different scan lists.

FAQ 2010-05-05

Can I upload instrument configurations and scanned data from an instrument?
Yes. To upload the instrument configuration and, if available, measured data, click Configuration > New by Upload...

FAQ 2010-05-05

How do I branch from one scan to another?
The Stop the scan and start the scan on action on the “Configure Events” tab, allows you to branch to another scan list on the occurrence of the corresponding event.

FAQ 2010-05-05

What is an Action Script and what can I do with it?
An Action Script contains one or more action steps that perform actions on modules in 34970A/34980A instruments, and other instrumentation connected to the PC.

FAQ 2010-05-05

How do I start a scan when using multiple scan lists?
Scanning always starts with the Base scan list.

FAQ 2010-05-05

Can two scan lists be running at the same time?
No. Only one scan list is active at any given time.

FAQ 2010-05-05

Can I reduce data while scanning?
No. All scanned data is saved in the datalog.

FAQ 2010-05-05

What are channel limits?
Limits can be set on multiplexer, totalizer and digital read channels (see the limit types question below).

FAQ 2010-05-05

How do I set channel limits?
On the “Configure Scan Lists” tab, after configuring a channel's measurement function, you can set limits by clicking in the channel's Limit Type column.

FAQ 2010-05-05

Can I use the National Instruments 34970A LabView Driver and Examples with the 34972A?
Yes, there is a new Labview driver that supports both the 34972A and the 34970A...

FAQ 2010-04-16