Technical Support
Test et mesure électronique
Refine the List
Par sujet
- Calibration (166)
- Configuration & Installation (825)
- Display Messages/Error Codes (170)
- Licensing (76)
- Measurement & Instrument Fundamentals (211)
- Measurement Techniques (532)
- Operating System & Software (298)
- Operation & Functionality (1115)
- Other Information (296)
- Parts & Accessories (307)
- Printing & Printers (34)
- Product & Firmware Updates & Upgrades (280)
- Product Theory of Operation (280)
- Programming & Data Transfer (511)
- Service & Maintenance (217)
- Specifications & Accuracy (344)
- Troubleshooting (120)
Par application
By Type of Content
- FAQ (7724)
Par catégorie de produit
201-225 of 7724
|
How can I get 1 GHz modulation bandwidth below 3.2 GHz?
There is a special option that down converts the wideband signal. It is: E8267D Option H1S PSG with 1 GHz out for use by the Z5623AK92 down converter, 500 MHz – 3.2 GHz.
FAQ 2012-12-28 |
|
|
What is the internal Arb trigger delay jitter?
The internal Arb trigger delay is generated using a free running oscillator.
FAQ 2012-12-28 |
|
|
Should the N7620B Signal Studio for Pulse Building software always use the N6030A arbitrary waveform generator built-in predistortion function?
Yes, the N6030A predistortion function works very well and should always be used.
FAQ 2012-12-28 |
|
|
Do corrections work with frequency and amplitude offsets?
Yes, however, the amplitude flatness accuracy is set by the spectrum analyzer flatness accuracy across the signal bandwidth...
FAQ 2012-12-28 |
|
|
How many coefficients should I use for custom FM?
The number of coefficients to use depends on the type of custom FM signal desired. Signal Studio for Pulse Building includes examples where 19 coefficients were used. The software allows as many coefficients as desired. The more coefficients used,...
FAQ 2012-12-28 |
|
|
What are the details related to using the N6030xA/M933xA and N824xA arbitrary waveform generator predistortion?
The built-in predistortion scales the data to guarantee that you never get a DAC over-range condition. Typically, it gives up 2-3 dB of range. This is important because less power out of the N6030A means less leveled output power from the PSG with...
FAQ 2012-12-28 |
|
|
Can I renew or extend the 30-day trial license after expiration?
After the trial license expires on an instrument, it cannot be renewed or extended.
FAQ 2012-12-28 |
|
|
How do I switch between trigger modes?
Any change between None, Continuous, or Single trigger mode requires only a "play" to update the Arb. Any change to or from the pulse trigger mode requires a "download and play". You must create a different waveform and sequence data for the pulse trigger mode.
FAQ 2012-12-28 |
|
|
How much time/frequency error is introduced by the Custom Profile or Custom I/Q resampling?
After using the formula to calculate the number of resampled data points, work backwards to determine the error.
FAQ 2012-12-28 |
|
|
Can multiple software applications communicate with a single N6030A arbitrary waveform generator at the same time?
Only one software application can communicate with the N6030A at a time.
FAQ 2012-12-28 |
|
|
What system configurations support ALC Hold?
Systems using the Internal Arb, Systems configured with the PSG and Option 016 and systems composed of the synthetic upconverter, N8212A...
FAQ 2012-12-28 |
|
|
What happens to nested patterns and off-time packets in pulse mode?
Nested patterns are flattened. This means that a single trigger will not play the entire pattern. It merely steps into the pattern and plays the first pulse. The next trigger plays the next pulse, etc. Off-time packets are ignored in pulse mode.
FAQ 2012-12-28 |
|
|
What happens when I turn the N6030A arbitrary waveform generator off?
You will probably need to reboot PC if you are using an MXI to PXI interface. All signal data is lost.
FAQ 2012-12-28 |
|
|
Is the performance of 0.4% EVM for 160 MHz 802.11ac best test result or average performance for N5182B MXG or N5172B EXG X-Series signal generators?
0.4% EVM is characteristic data of a small sample of N5182B MXG signal generators using the PXA and VSA 89601B.
FAQ 2012-12-26 |
|
|
How does DC calibration affect channel corrections?
If a DC calibration is run with channel corrections applied, this may or may not degrade performance slightly.
FAQ 2012-12-26 |
|
|
Which USB power sensors are supported on the X-Series signal generators?
All Agilent U200xx USB power sensors are supported. in the future, ...
FAQ 2012-12-26 |
|
|
Do User channel corrections cover multiple attenuator steps?
Yes. Bypass step, 0 dB step, and 5 dB step.
FAQ 2012-12-26 |
|
|
For User channel correction calibration, is it better to do a spot user cal or over an overlapping range?
Overlapping is good idea, but not required.
FAQ 2012-12-26 |
|
|
When you perform the User channel correction routine, do you need to compensate for the cable between spectrum analyzer or power meter and source?
No, the cable error has been calibrated.
FAQ 2012-12-26 |
|
|
Is there SCPI code compatibility from the 8662A or 8663A to the X-Series signal generators?
Yes
FAQ 2012-12-26 |
|
|
Are there any S1 S2 measurements with power sensors on the X-Series signal generators?
No, however, the “User” channel correction routine in X-Series vector signal generators measures DUT channel response in phase and amplitude with power sensor.
FAQ 2012-12-26 |
|
|
Do temperature changes affect the factory channel correction calibration?
temperature changes, channel correction calibration, factory correction calibration,x-series signal generators
FAQ 2012-12-26 |
|
|
For User channel correction, how many unique calibration files are supported?
We can support thousands on internal solid state drive.
FAQ 2012-12-26 |
|
|
Can running user correction calibration over a narrower range improve calibration?
No, the number of points is always fixed at a 5 MHz interval
FAQ 2012-12-26 |
|
|
Is the channel correction a new feature?
No, it has been available on the MXG since 2009. However, the functionality in the X-Series signal generators has been significantly improved since the first-generation MXG implementation.
FAQ 2012-12-26 |
|