How can I order the operation notes for the 4285A options 201, 202 and 301?
FAQ 2009-05-26 |
|
|
What are differences between the 16047A and 16047D?
FAQ 2009-05-26 |
|
|
What documents and accessories will I receive with my new N8300A?
Items include a Getting Started Guide, a BNC Cable, and a USB Cable. Click on the question above for a fuller description.
FAQ 2009-04-30 |
|
|
What documents and accessories will I receive with my new E6651A?
Items include a Getting Started Guide and a Handle Kit. Click on the question above for a fuller description.
FAQ 2009-04-30 |
|
|
What is the limitation of the evaluation mode of the MWA software?
The number of measurements is limited with the evaluation mode of the MWA back-end application.
FAQ 2009-04-19 |
|
|
Which upgrade kit should be ordered for the E5100A JP4KC00945 to install the latest hardware?
To install the latest hardware (JP5KCxxxxx), one of the following upgrade kits should be ordered.
FAQ 2009-04-13 |
|
|
What documents and accessories will I receive with my new N4011A?
Items include a Getting Started Guide, a Control Cable, and a Semi-Rigid RF Cable. Click on the question above for a fuller description.
FAQ 2009-03-20 |
|
|
What documents and accessories will I receive with my new N4010A?
Items include a Getting Started Guide, a Certificate Of Calibration, and a USB Cable. Click on the question above for a fuller description.
FAQ 2009-03-19 |
|
|
Is there a 16060A-like transformer test fixture usable with the 4284A?
No transformer test fixture for the 4284A is available.
FAQ 2009-03-11 |
|
|
What are the dimensions of the working standards supplied with the option 4287A-004?
FAQ 2009-03-11 |
|
|
Is there a 16060A-like transformer test fixture usable with the E4980A?
No transformer test fixture for the E4980A is available.
FAQ 2009-03-11 |
|
|
Can the 16092A Spring Clip Fixture be used with the 4287A?
Yes. Please refer to Test Fixtures/Accessories Quick Reference Matrix.
FAQ 2009-03-11 |
|
|
What are the part numbers for the cables necessary to create a multi-card logic analyzer module?
16753/4/5/6A, 16910/11A, and 16950/51A/B need 16754-60002. 16715/6/7/8/9A, 16740/41A, 16750/51/52A/B, and 16760A need 16715-60001.
FAQ 2009-03-06 |
|
|
85070E/85071E: What Are the Part Numbers for 7mm and 3.5mm Airlines for Materials Measurements?
7mm airline 85051-60010
3.5mm airline 85053-60008
FAQ 2009-02-17 |
|
|
What compensation should I perform when I use the 16048B with the 4285A?
It is recommended to set the Cable Length function of the 4285A to "1 m" and perform open/short/load compensation at the DUT contact terminals of the test fixture connected to the tip of the 16048B.
FAQ 2009-01-13 |
|
|
How can I get a 0603 size LOAD standard that can be used to perform LOAD correction using the 16196C and other SMD test fixtures?
Agilent part number 0699-6926 can be used as a LOAD standard. It is a 51-ohm chip resistor.
FAQ 2009-01-13 |
|
|
Can I use the 16048B with the 4285A for the cable extension?
Yes, the 16048B (Part Number 16048-60030) can be used with the 4285A. But, it is not easy to perform the cable correction using the 100-ohm resistor box (furnished with the 4285A).
FAQ 2009-01-13 |
|
|
How can I obtain the open and short terminations which are not supplied with the 42030A?
The 42090A Open Termination and the 42091A Short Termination are available as the four-terminal-pair open/short reference terminations.
FAQ 2009-01-13 |
|
|
Isn't the current 16034E equipped with a dual-post stopper while previous ones had the stopper attached to the right side of Hcur connector?
The 16034E currently has no stopper because all impedance analyzers that required the stopper became obsolescence by 2001.
FAQ 2009-01-13 |
|
|
Can a DC bias current be applied to an inductor DUT when the 16065C is used with the 4263B?
No, the 16065C can only be used to apply a DC voltage bias.
FAQ 2009-01-13 |
|
|
Why is the cylindrical insulator used in the 16196A/B/C/D test fixtures, which surrounds the DUT?
The cylindrical insulator in the 16196A/B/C/D is used to accurately position the DUT in the coaxial fixture, preventing the DUT's electrodes from contacting the outer conductor (ground) of the fixture.
FAQ 2009-01-13 |
|
|
What should I care in order to ensure good measurement correlation between the 16196A/B/C/D and other Agilent test fixtures?
FAQ 2009-01-13 |
|
|
What are the differences between the 16048A and the 16048D?
The differences between the 16048A and 16048D are shown in the table below...
FAQ 2009-01-13 |
|
|
How should open compensation be performed on the 16034E/G/H?
Locate the High and Low side contact pins the same distance apart as the length of the DUT by using the following procedure...
FAQ 2009-01-13 |
|
|
How can I replace the contact electrodes of the 16118A?
The contact electrodes of the 16118A cannot be replaced by user.
FAQ 2009-01-13 |
|