What is the board weight specification?
For the Series II SP50 and SJ50 systems, the specification is <3kg.

FAQ 2009-02-26

What are the effects of AOI on the environment, for example, does the use of lasers affect the operators?
AOI systems usually have no effect on the PCB or the environment.

FAQ 2009-02-26

What are the reasons for choosing an inline solder paste inspection system over an on-board solder paste inspection solution offered on the screen ...
Screen printing with on-board solder paste inspection solutions is typically very slow, so it negatively impacts throughput.

FAQ 2009-02-26

Is there a way to pull the results from my SP50 into a report?
Yes, a reporting package is available on the system.

FAQ 2009-02-26

What are the advantages and disadvantages of Agilent AOI systems compared to other systems?
The various AOI systems in the market have their unique features but Agilent has a unified platform which protects one's investment.

FAQ 2009-02-26

How do you test solder paste volume and quality, and what are the advantages compared to visual inspection?
Agilent's SP50 solder paste inspection system uses laser inspection to check the solder paste volume, height, area, and offset (all of the print related parameters).

FAQ 2009-02-25

Are the alarm settings saved in the SPC software?
Yes, the alarm settings are saved in the SPC software.

FAQ 2009-02-25

What units are the area and volume in for the SP50 measurements?
By default the SP50 displays and reports area and volume as normalized percentages.

FAQ 2009-02-25

AOI is able to detect solder paste missing or offset but can it detect solder paste volume? And it's height?
The Agilent SP50 is able to test solder paste missing & offset as well as solder paste height and volume.

FAQ 2009-02-25

Can the operator access the alarm limits in the SPC software?
Yes, the operator can access the alarm limits in the SPC software.

FAQ 2009-02-25

What is the minimum sensitivity of the N897xA NFA Series?
Sensitivity is not a specified parameter

FAQ 2009-02-09

How can I access to the maximum memory depth (32M/16M) as stated in the U2701A/U2702A Modular Oscilloscope's datasheet?
You can see the effects of maximum memory depth 32/16 Mpts in zoom mode….

FAQ 2009-02-04

Do the U2300A Series USB DAQ devices provide opto-isolation of the analog inputs?
No, the U2300A Series USB DAQ devices do not provide opto-isolation of the analog input channels.

FAQ 2009-02-04

How do I calculate the dc vertical gain accuracy of a U2701A/U2702A USB Modular Oscilloscope?
The dc vertical gain accuracy of a U2701A/U2702A USB Modular Oscilloscope depends on the error values in the measured value....

FAQ 2009-02-04

What is the output impedance of the 4285A?

FAQ 2009-01-14

Does the Agilent Measurement Manager (AMM) support regional language settings other than English (US)?
Yes, the Agilent Measurement Manager (AMM) supports regional language settings other than English (US)….

FAQ 2009-01-12

Can the spectrum analyzer mode of the 4395A display noise level below 0.0001 µV / sqrt (Hz) in noise measurement mode?
No, the 4395A can't display noise level below 0.0001 µV / sqrt (Hz) in noise measurement mode.

FAQ 2008-11-16

Is the accuracy of the impedance measurement specified when the 4395A/4396B Option 010 is used with the 87512A?
No, the accuracy of the impedance measurement values obtained by using the 4395A/4396B with the 87512A is not specified.

FAQ 2008-11-16

What does the Input Impedance in Table 11-24 of E4980A User's Guide and Table 39 of E4980A datasheet mean and how should it be applied?
The Table 11-24 and Table 39 describe input impedance of DC bias current monitor.

FAQ 2008-11-12

What is the signal source output impedance of the 4338B?
The signal source output impedance is 1 ohm +/- 0.2 ohms (not specified).

FAQ 2008-11-11

How accurately does the 4338B measure high resistance?
The 4338B accuracy in high resistance measurement is degraded because the maximum measurement range is limited to 100 k ohms.

FAQ 2008-11-11

ESA-L1500A: Spectrum Analyzer Frequency Reference

FAQ 2008-10-08

What is the maximum analog output current from the U2300A Series Data Acquisition (DAQ) devices?
The maximum analog output current from the U2300A Series Data Acquisition (DAQ) devices is 5mA.

FAQ 2008-09-25

Are the USB data acquisition (DAQ) devices compatible with USB 1.1 or USB 2.0?
The USB data acquisition (DAQ) devices come with Full Speed USB (12Mbps) which is compatible with any USB Host 1.1 and 2.0.

FAQ 2008-09-25

What is the lowest sampling rate that can be set for the U2300A/U2500A Series USB Data Acquisition (DAQ) devices?
The Agilent U2300A/U2500A Series Data Acquisition (DAQ0 devices can support sampling rates as low as 3Sa/s.

FAQ 2008-09-25