When I sent commands using VISA (Both Agilent VISA and NI VISA), why must i put '\n' or '\r' after the commands for U2600A…
Please upgrade your U2600A firmware to version 1.05 or above
FAQ 2010-08-09 |
|
|
Why do the error messages "1105: Could not connect to License Server. Please restart application" and "1003: Failed to connect …
The error messages appear when the N1918A Power Analysis Manager is launched because the Agilent License Service sometimes does not start….
FAQ 2010-08-09 |
|
|
Matlab throw this error with U2300A/U2500A
"??? Error using ==> daqhwinfo at 115
Failure to find requested data acquisition device: agilentu2500....
Please check whether your Matlab adaptor is installed at the following path:.....
FAQ 2010-08-09 |
|
|
When I press the Power On button on my U1602A/U1604A Handheld Oscilloscope, it does not boot up. Instead, the screen just flashes …
To turn on your U1602A/U1604A Handheld Oscilloscope, you will need to press and hold the Power On button for approximately 3 seconds….
FAQ 2010-08-09 |
|
|
Why does the “C-End” (charge end) message appear on the secondary display of the U1252A Handheld Multimeter…
When the “C-End” message is displayed, it actually indicates that the battery is fully charged…
FAQ 2010-08-09 |
|
|
What should I do when seeing crash during the installation of Power Analyzer (software licensing version) into my non-English version of Windows…
The workaround steps to resolve this are listed below….
FAQ 2010-08-09 |
|
|
When using the U1602A/U1604A Handheld Oscilloscope, I can see an offset value at the vertical axis although there is no connection…
When you see an offset value at the vertical axis although there is no connection at the test probe, try running the self-calibration….
FAQ 2010-08-09 |
|
|
What should I do when my Power Analyzer (software licensing version) still goes into trial version even though a valid license was installed…
When this situation happens, try the following steps to get this resolved:
FAQ 2010-08-09 |
|
|
Why do we see unused port in U2300A/U2500A with similar waveform and frequency but with lower amplitude to its adjacent or close by used port?
It is recommended to ground all the AI connection that is not being used. If you have multiples of AI channels to be used, one good way is to have…
FAQ 2010-08-09 |
|
|
Why is my acquired data for U2300A and U2500A shifted? eg. Column 2 data is in column 1, column 3 data is in column 2, and so on.
Install DAQ hardware driver version 1.05 and above.
FAQ 2010-08-09 |
|
|
Why does the new U1571A battery pack for my U1602/4A Handheld Oscilloscope last less than the stipulated 4 hours…
The new U1571A battery pack of the U1602A or U1604A Handheld Oscilloscope lasts less than 4 hours because….
FAQ 2010-08-08 |
|
|
I get error from the example "C:\Program Files\Agilent\RF Switch Driver\Examples\VS.NET\CSharp\Example1".
The temporary solution to this is to load the U2931A .dll file that was not loaded with the...
FAQ 2010-07-18 |
|
|
How do I convert *.svw file to *.csv file in PC Link for U160xA/B?
1) From within PC Link, click on the "Load SVW" icon on the tool bar...
FAQ 2010-07-18 |
|
|
When do I need to perform “Calibrate All” and “Calibrate I/Q Balance” on my N4010A?
There are several scenarios where we recommend you do both calibrations. Click on the question above for a fuller description.
FAQ 2010-07-07 |
|
|
No Title
Instead of the ("Counter value"/"48 x 10^6") as the duration in seconds taken to count, it is...
FAQ 2010-05-10 |
|
|
Is number of bits the only factor to look at if I'm measuring at very low voltage say 5mVpp?
No it is not. Often times, you will have to look at the Gain Error and Offset Error as well as...
FAQ 2010-05-10 |
|
|
Why USB modular instruments (U272XA, U2741A, U2751A and U2761A) is not detectable by E5813A?
PC is failed to enumerate the USB modular instrument.
FAQ 2010-04-09 |
|
|
Why my N8300A will shut down when I select restart?
The application at N8300A must be close before you restart.
FAQ 2010-03-24 |
|
|
How to check the condition of the fuses in U1253A/U1253B before you use it?
To test the fuses inside the U1253A/U1253B OLED display DMM, just follow the instructions as follows…
FAQ 2010-03-22 |
|
|
Why does my N4010A sometimes fail EDR Relative Power on a good DUT?
This may happen if the firmware is A.05.03.10 (or newer).
FAQ 2010-02-02 |
|
|
My InfiniiMax probe fails calibration or does not accurately pick up the cal signal when I use the E2655A test fixture. What could be wrong?
The first step in troubleshooting a failed probe calibration should be to compare the actual signal and the probed signal. If the probed signal does not track the actual signal well, it is most likely due to a poor connection.
FAQ 2010-01-10 |
|
|
Is there any special setting that I need to do in Agilent VEE before using the U2300A or U2500A DAQ with it?
Yes. In fact it is the most important thing you need to set before using the DAQ with Agilent VEE. As most instruments uses MSB byte ordering, DAQ...
FAQ 2009-12-15 |
|
|
What is the main difference between the digital output (DO) of the U2100A, U2600A, U2300A and U2500A?
The DO port of U2100A and U2600A requires external power supply to be pumped into the port...
FAQ 2009-10-20 |
|
|
Can I export the interval logging data saved in the internal memory of my U1253A Handheld Multimeter?
Yes, you can export the interval logging data saved by upgrade your U1253A Firmware revision to V1.20…..
FAQ 2009-09-29 |
|
|
Check disk often runs when the E5070B/71B or E5061A/62A power up. Why?
Shutdown process might be failed. Uninstall the unsupported software or use special shutdown process when you want to shutdown the unit.
FAQ 2009-08-25 |
|