Which Agilent oscilloscopes have a 10 MHz reference input/output?
6000 Series, 6000L Series, 7000A Series, 7000B Series, 9000 Series, 54850 Series (Output only), 80000A Series, 80000B Series, 90000A Series and 90000 X-Series

FAQ 2012-09-29

What is the difference between the Auto and Normal trigger modes on InfiniiVision oscilloscopes?
In auto trigger mode, the trigger will be forced if the specified conditions are not met. In normal trigger mode, the trigger will never be forced and a trigger will only occur if the specified conditions are met.

FAQ 2012-09-29

Can I manually set the sample rate on my InfiniiVision oscilloscope?
Although the sample rate cannot be directly set on any InfiniiVision oscilloscope, it can be set indirectly by adjusting the oscilloscopes time per division setting.

FAQ 2012-09-29

How do I get >8 bit vertical resolution on my Agilent real-time oscilloscope?
Most Agilent oscilloscopes give 8-bit vertical resolution at normal acquisition mode.

FAQ 2012-08-31

What is the typical power consumption of the 86100C and 86100D Digital Communications Analyzer?
Typical measurements of 86100C and 86100D power consumption

FAQ 2012-08-06

세그멘티드 메모리 옵션, N5454A를 구매했습니다. 메뉴에서 찾을 수가 없습니다. 어떻게 해야 하나요?
세그멘티드 메모리는 firmware 5.10 이상에서 동작합니다.

FAQ 2012-07-31

Which probe positioners are available to hold the N1021B?
The adapter provided with the N1021B is generic enough to work with robot arms or common industry positioners ...

FAQ 2012-07-06

How do I establish a peer-to-peer connection between my PC and an InfiniiVision 5000/6000/7000 Series oscilloscope?
There are two methods ...

FAQ 2012-03-27

ENA는 액티브 프로브에 대해 프로브 전원 연결을 제공합니까?

FAQ 2012-03-16

인피니비젼 스코프에서 오토스케일 기능을 끌 수 있나요?
전면 판넬 동작으로는 불가능 합니다.

FAQ 2011-10-23

Why i can't find other languages help file setting in U160X A/B series HH oscilloscope?
In order to access to other language, please go to respective product support page in www.Agilent.com. Go to Driver & Software page, select Firmware Update.

FAQ 2011-09-12

How can I perform TDR measurements using the 86100D mainframe with the standard trigger option, 86100D-STR?
If you want to use two TDR modules in an 86100D with option STR then you either have to move the cable to the module that sends out the TDR pulses, or you have to use two cables (such as Agilent P/N 5062-6687) and a power divider (such as Agilent’s P/N 11636B) or power splitter (such as Agilent P/N 11667B). The common port should go into the trigger input.

FAQ 2011-04-25

Are the input channels on the U1602B and U1604B Handheld Oscilloscopes isolated?
No, both scope channels (channel 1 and channel 2) on the U1602B and U1604B Handheld Oscilloscopes are not isolated.

FAQ 2011-03-31

Do the 1000 Series oscilloscopes provide the ability to switch off the Auto Scale feature?
Not on the front panel, but you can do it with remote programming commands.

FAQ 2011-03-14

Can U1602A/B and U1604A/B measure capacitance of 0.13nF?
Based on the datasheet, for 0.13nF, it falls in the range of 60nF. To calculate the range of fluctuation of the reading,…

FAQ 2010-12-20

How do I extract the 32Mpts from U270xA?
One way of “viewing” the full memory waveform is using the zoom function (that the red arrow...

FAQ 2010-09-14

생산 중단되었거나 폐기된 HP 및 애질런트 테스트 장비 매뉴얼은 어디서 구할 수 있습니까?
매뉴얼을 다양한 방법으로 검색 또는 요청하실 수 있습니다.

FAQ 2010-09-13

Why does the pulse shape of my scope probe compensation look different from the pulse shape shown…
The compensation signal (square wave) that you see is different from the pulse shape shown in the U1602A/U1604A's user’s manual because….

FAQ 2010-08-09

How do I convert *.svw file to *.csv file in PC Link for U160xA/B?
1) From within PC Link, click on the "Load SVW" icon on the tool bar...

FAQ 2010-07-18

When will Agilent USB modular instruments and USB Modular DAQs supports Windows 7?
For 32 bit Windows 7, the supportability of modular instruments and DAQs will happen...

FAQ 2010-07-18

What is the update rate for U1600A series handheld scope?
update rate is 14 waveforms per second

FAQ 2009-08-06

Why does handheld scope’s date/time display disappears or shows hexa characters?
This condition indicates that the internal memory battery level is low.

FAQ 2009-07-16

Why does handheld scope’s DMM measurement frequently stall after one hour of continuous operation?
This condition indicates that the internal memory battery level has dropped to 1.4V or lower.

FAQ 2009-07-16

How do you connect a 12GHz probe with a solder-in probe tip to the BNC port?
For best accuracy use the E2655B kit to perform the probe calibration on the DCA ...

FAQ 2009-06-22

Is there any communication between the DCA mainframe and the 1169A probe via the N1022A adapter?
You have to select the probe model number in the graphical user interface (GUI) of the 86100X mainframe ...

FAQ 2009-06-22