How do you clear the M9381A PXIe Vector Signal Generator and M9380A PXIe CW Source modules memories?
Please refer to the documents for a comprehensive listing of memory installed into these products.

FAQ 2013-05-20

How do you clear the M9036A Embedded Controller memories?
Please refer to the link below for the procedure on how to clear the memories for the M9036A Embedded Controller.

FAQ 2013-03-15

How do you clear the M9536A Embedded Controller memories?
Please refer to the link below for the procedure on how to clear the memories for the M9536A Embedded Controller.

FAQ 2013-03-15

Which AXIe modules can be controlled using the USB option on the AXIe chassis ESM (M9502A-U20 and M9505A-U20)?
The only modules supported through USB connectivity to a host PC are the following Agilent logic and protocol analyzer modules.

FAQ 2013-01-09

On my E8267D, I get an error that the signal requires more repeats than supported, can I increase this limit with the internal baseband option?
No. To increase the number of pulse capacity either upgrade to an External Baseband option with the N8241A AWG or ...

FAQ 2012-12-30

How do you clear the 34980A multifunction switch/measure mainframe and modules, L44xxA series LXI switch and control instruments memories?
Please refer to the documents for a comprehensive listing of memory installed into these products.

FAQ 2012-12-12

How can previously created data in BenchLink II be exported?
Open a previously saved configuration file with data and then export the data as a Text (.txt) file or Comma Separated values (.csv) file.

FAQ 2012-11-05

How do you clear the M9045A, M9045B, M9047A and M9048A memory?
Please refer to the link below for the procedure on how to clear the memory for the M9045B and M9048A adapters.

FAQ 2012-05-01

The Agilent 8761B SPDT Coaxial Switches are not listed in the "Agilent 34945A, L4445A and L4490A/L4491A Configuration Guide". Why?
Due to the 8761B’s internal design the RF path selection is achieved via DC polarity reversal across the coil control terminals. The Agilent 34945A, L4445A and L4490A/L4491A Control Units do not provide a polarity reversal mode. Thus the 8761B cannot be controlled by the 34945A, L4445A and L4490A/L4491A Control Units.

FAQ 2011-12-19

How do you clear the M9202A PXI Express 12-bit Wideband IF Digitizer memory?

FAQ 2011-08-18

Where can I find manuals for discontinued and obsolete Hewlett-Packard and Agilent test equipment?
Most Agilent products have PDF manuals that can be found on product pages. Other vendors also supply old manuals.

FAQ 2011-07-13

How do you clear the M9502A and M9505A AXIe Chassis memory?

FAQ 2011-07-08

How do you clear the M91xxA memory?

FAQ 2011-06-22

Is a dual-M9018A chassis configuration using NI PCIe-8372 connected to NI PXIe-8370 modules supported?
A dual-M9018A chassis configuration using NI PCIe-8372 and NI PXIe-8370 modules is supported...

FAQ 2011-03-08

Is it normal to not be able to set sample point in AMM for U2300A/2500A?
Yes. AMM assigns the sample point automatically.

FAQ 2010-12-20

Must we need 2 units of SCSI cable connected in between U2802A and U2355/56A?
Yes.

FAQ 2010-12-20

Why are the 435/6/7/8A/B Power Meter, 53147/8/9A Microwave Counter/Power Meter/DVM, 70100A MMS Power Meter …
The 435/6/7/8A/B, 53147/8/9A, 70100A, E1416A and E7495A/B are incompatible with the N8480 Power Sensors because….

FAQ 2010-10-31

How do I rack mount two instruments of different depths?
There are three ways to rack instruments of different depths side-by-side; for example, an Agilent 33220A with an Agilent 34401A.

FAQ 2010-10-12

How can I input 28V digital signal to U2651A/U2652A when it support digital input voltage < 24V?
You can connect a voltage divider in front of the digital input to reduce the voltage to <24V

FAQ 2010-10-07

Can I use the PXIe products over LAN?
If the PXIe chassis has an embedded controller with a LAN port then the PXI system can connect to a LAN port...

FAQ 2010-10-06

Can I run a program that is controlling my PXI instrument while using its soft front panel (SFP)?
Not at this time...

FAQ 2010-10-06

Can I replace other vendors' module (for example a digitizer) with an Agilent one?
There are two aspects to consider...

FAQ 2010-10-06

Will ExpressVIs work with Agilent hardware?
No. Agilent has VIs available to use with LabView but not ExpressVIs.

FAQ 2010-10-06

What is the difference between PXIe and AXIe?
The AXIe standard provides the maximum scalability to address a range of platforms...

FAQ 2010-10-06

Where can customers find user manuals and example programs for AXIe & PXIe products?
Datasheets of modular products will be included on the CD shipped with every product and will be available on Agilent.com from the product page...

FAQ 2010-10-06