Why should I use Amplitude Offset?
Use the Amplitude Offset feature to account for any external gain or loss that is greater than 10 dB.
FAQ 2012-12-28 |
|
|
Why do I want to mirror the spectrum?
Mirror Spectrum reverses the spectrum of the waveform when it is downloaded. This is useful for systems with external upconversion and downconversion where the signal spectrum is mirrored by the conversion process.
FAQ 2012-12-28 |
|
|
What happens when I turn the N6030A arbitrary waveform generator off?
You will probably need to reboot PC if you are using an MXI to PXI interface. All signal data is lost.
FAQ 2012-12-28 |
|
|
What are the details related to using the N6030xA/M933xA and N824xA arbitrary waveform generator predistortion?
The built-in predistortion scales the data to guarantee that you never get a DAC over-range condition. Typically, it gives up 2-3 dB of range. This is important because less power out of the N6030A means less leveled output power from the PSG with...
FAQ 2012-12-28 |
|
|
What system configurations support ALC Hold?
Systems using the Internal Arb, Systems configured with the PSG and Option 016 and systems composed of the synthetic upconverter, N8212A...
FAQ 2012-12-28 |
|
|
What is the internal Arb trigger delay jitter?
The internal Arb trigger delay is generated using a free running oscillator.
FAQ 2012-12-28 |
|
|
How many coefficients should I use for custom FM?
The number of coefficients to use depends on the type of custom FM signal desired. Signal Studio for Pulse Building includes examples where 19 coefficients were used. The software allows as many coefficients as desired. The more coefficients used,...
FAQ 2012-12-28 |
|
|
Is the channel correction a new feature?
No, it has been available on the MXG since 2009. However, the functionality in the X-Series signal generators has been significantly improved since the first-generation MXG implementation.
FAQ 2012-12-26 |
|
|
Which USB power sensors are supported on the X-Series signal generators?
All Agilent U200xx USB power sensors are supported. in the future, ...
FAQ 2012-12-26 |
|
|
Are there any S1 S2 measurements with power sensors on the X-Series signal generators?
No, however, the “User” channel correction routine in X-Series vector signal generators measures DUT channel response in phase and amplitude with power sensor.
FAQ 2012-12-26 |
|
|
Do User channel corrections cover multiple attenuator steps?
Yes. Bypass step, 0 dB step, and 5 dB step.
FAQ 2012-12-26 |
|
|
Is there SCPI code compatibility from the 8662A or 8663A to the X-Series signal generators?
Yes
FAQ 2012-12-26 |
|
|
Is the performance of 0.4% EVM for 160 MHz 802.11ac best test result or average performance for N5182B MXG or N5172B EXG X-Series signal generators?
0.4% EVM is characteristic data of a small sample of N5182B MXG signal generators using the PXA and VSA 89601B.
FAQ 2012-12-26 |
|
|
What is embedded software versus Signal Studio software?
View table with descriptions
FAQ 2012-12-14 |
|
|
How do you clear the 34980A multifunction switch/measure mainframe and modules, L44xxA series LXI switch and control instruments memories?
Please refer to the documents for a comprehensive listing of memory installed into these products.
FAQ 2012-12-12 |
|
|
When I use the 30-day trial license of the Signal Studio for WiMAX™, how can I check the number of days remaining on temporary license?
Press the front panel keys: Utility > Instrument Adjustments > Instrument Options > Waveform Licenses
FAQ 2012-12-11 |
|
|
How often does the system user alignment for the PSA EMI Measurement Receiver need to be run?
30 days or 3° C temperature change. See contents for details...
FAQ 2012-12-11 |
|
|
Do I need to perform a periodic front panel instrument alignment on my N9039A RF Preselector?
No, but there is a system alignment that needs to be periodically run. See FAQ content for details...
FAQ 2012-12-11 |
|
|
What is the process to capture a trace image to the floppy disk on the Agilent 8712ES/ET and 8714ES/ET Vector Network Analyzers?
The 8712ES/ET and 8714ES/ET Vector Network Analyzers support HPGL, PCX, PCL5, and GIF image saves via the floppy drive.
FAQ 2012-12-11 |
|
|
66xxA, E363xA and E364xA: Can Agilent Power Supplies Sink Current?
Yes! Sinking, or down-programming, is the ability to pull current into the positive terminal of a power supply.
FAQ 2012-12-07 |
|
|
What Configuration issues are there with option AYQ, Quasi Peak Detector in the ESA-E Series of Spectrum Analyzers?
View the compatibility issues here....
FAQ 2012-12-05 |
|
|
What you need to know about Advanced DGN Reporting?
Frequently Asked Questions about Advanced DGN Reporting.
FAQ 2012-11-28 |
|
|
How to debug the 3 differences that are encountered on the new hybrid pin cards (P/N: E4000-66562 and E4000-66563)?
Follow the guideline to debug your test when you start using the new bybrid pin cards:
• E4000-66562 for 6MPs (standard hybrid pin card)
• E4000-66563 for 12MPs (advanced hybrid pin card)
FAQ 2012-11-12 |
|
|
How can previously created data in BenchLink II be exported?
Open a previously saved configuration file with data and then export the data as a Text (.txt) file or Comma Separated values (.csv) file.
FAQ 2012-11-05 |
|
|
Are there any reference documents for TRL Calibration of network analyzers?
FAQ 2012-11-05 |
|