How do I erase/clear the user data in an ESA or EMC series spectrum analyzer for security reasons?
Follow this link for further information....
FAQ 2012-03-16 |
|
|
Why don't the Measure at Marker or Auto Measure peak detector values match the peak trace marker values on my EMC analyzer?
Your instrument firmware may need to be updated....
FAQ 2012-03-16 |
|
|
On the ENA 6 series, can I get TTL signal indicating Pass/Fail of the limit test like the 871x?
Yes.
FAQ 2012-03-16 |
|
|
What advantages does the expanded memory option (option 003) on the 16700 Series Logic Analyzers provide?
Generally, expanded memory will provide enhanced performance with certain hardware configurations and will support monitor resolutions up to 1600 X 1200.
FAQ 2012-03-12 |
|
|
What is the resolution of the VGA monitor output from the 8560EC Series spectrum analyzer?
640 x 480
FAQ 2012-03-02 |
|
|
How do I transfer the time capture buffer data from my 89441A or 89410A VSA to a PC?
There are several ways to transfer the data in the time capture buffer after a recording has been made. The easiest way is to use FTP over LAN, but there are other programmatic ways too.
FAQ 2012-03-02 |
|
|
Will the handheld spectrum analyzers have an LXI C class (web server)?
No, there is no plan for an LXI C class (web server).
FAQ 2012-03-02 |
|
|
Are the remote control commands of the handheld spectrum analyzers compatible with any other instrument?
The remote control command set of the handheld spectrum analyzers is compatible with the command sets of other spectrum analyzers.
FAQ 2012-03-02 |
|
|
What is the fastest pulse risetime that I can measure with my spectrum analyzer in zero span?
The measurement risetime may not be faster that the best risetime of the spectrum analyzer
FAQ 2012-03-02 |
|
|
How can I make field strength measurements on my handheld spectrum analyzer?
Each of the HSA products supports field strength measurements.
FAQ 2012-03-02 |
|
|
How much the default RF port power of N4375B? And can I change it?
It is 0 dBm, and you can change it.
FAQ 2012-03-01 |
|
|
Do the handheld spectrum analyzers offer a tracking generator?
Yes, all HSA models have a tracking generator option.
FAQ 2012-03-01 |
|
|
What graphics format does the E7495A/B Wireless Base Station Test Set support for saving screen captures to compact flash or PCMCIA memory card?
The E7495A/B can save screen images in the Portable Network Graphics (PNG) format. This format is a lossless compression graphics format that is supported by Microsoft Office 97 and later, Microsoft Internet Explorer, and Netscape Navigator.
FAQ 2012-02-28 |
|
|
Which channel plans does the E7495A/B Wireless Base Station Test Set Support?
The following channel tuning plans are supported by the E7495A/B: Japan CDMA, Korean PCS CDMA, Secondary 800 CDMA, IMT-2000 CDMA, GSM-850, GSM-900, GSM DCS-1800, GSM PCS-1900, North American Cellular AMPS, and NMT-450
FAQ 2012-02-28 |
|
|
How do I connect a PSA Series Spectrum Analyzer to the 89601A Vector Signal Analysis Software?
The 89601A software must be installed on a PC that has either a USB, GPIB or LAN interface. Agilent IO Libraries must also be properly configured.
FAQ 2012-02-28 |
|
|
Where can I see an on-line demonstration of the PSA Series Spectrum Analyzer?
Click here to see a selection of on-line demonstrations.
FAQ 2012-02-26 |
|
|
What is the frequency coverage of the N5532A/N5532B sensor module? What options would my PSA Analyzer require to operate in an N5531S?
The N5532A/N5532B is offered in four optional frequency ranges. All models can measure power from -20 dBm to +30 dBm.
FAQ 2012-02-26 |
|
|
How do I include Mismatch Uncertainty into the N5531S Measuring Receiver Absolute Amplitude accuracy?
The N5531S Measuring Receiver System is comprised of a PSA Series Spectrum Analyzer with Option 233 (measuring receiver personality), a P-Series or an EPM Series Power Meter, and an N5532B (or N5532A) Sensor Module.
FAQ 2012-02-26 |
|
|
What is the frequency range of the N5532A Sensor Module?
100 kHz to 4.2 GHz, 10 MHz to 18 GHz, 30 MHz to 26.5 GHz, and 30 MHz to 50 GHz.
FAQ 2012-02-26 |
|
|
Why do spurious signals appear in my spectrum analyzer span when I apply a clean signal to the RF input?
Overdriving the input mixer of the analyzer may cause the spurs.
FAQ 2012-02-26 |
|
|
What is the frequency range of the N5532B Sensor Module?
100 kHz to 4.2 GHz, 10 MHz to 18 GHz, 30 MHz to 26.5 GHz, and 30 MHz to 50 GHz.
FAQ 2012-02-26 |
|
|
Can the ESA-E Series Spectrum Analyzer Noise Figure Personality, Option 219, be used with external mixing Option AYZ?
No, the ESA-E Series Spectrum Analyzer Noise Figure Personality Option 219 does not incorporate the external mixing functionality offered with option AYZ.
FAQ 2012-02-25 |
|
|
Is the ESA-E Series Spectrum Analyzer Noise Figure option code compatable with the NFA Noise Figure Analyzer?
The NFA and the ESA-E Series Noise Figure Measurement Personality are approximately 90% code compatible for the features they have in common.
FAQ 2012-02-25 |
|
|
Can I use the internal microwave preamp, Option H26, with the ESA-E Series Spectrum Analyzer Noise Figure solution?
We do not recommend using the Option H26 internal microwave preamp at this time. Option H26 has not been tested for compatability with the Noise Figure Measurement Personality.
FAQ 2012-02-25 |
|
|
How can I transfer trace data from the 89400 VSA to my PC?
The VSA always saves data in standard data format; the utility is run from the DOS prompt.