251-275 of 7799

Sort:
How do I use the Service Request method (SRQ) to determine if the X-Series, ESA and PSA Signal Analyzers measurement is complete or has an error me...
Click here for information on the Service Request query to determine when a measurement is complete.

FAQ 2013-06-25

What are the deep signal capture capabilities for the N9030A Signal Analyzer?
Details found here...

FAQ 2013-06-25

How can I order the upgrade kit of the 4395A
The model numbers of available upgrade kits for the 4395A options are as follows.

FAQ 2013-06-24

M9216A memory sanitization
M9216A memory sanitization

FAQ 2013-06-21

PDF PDF 48 KB
M9185A memory sanitization
M9185A memory sanitization process

FAQ 2013-06-21

PDF PDF 47 KB
M9186A memory clearing process
this document provides information regarding the memory clearing process for M9186A

FAQ 2013-06-18

PDF PDF 47 KB
89600 VSA software and X-Series signal analyzer software compatibility matrix
Supported versions listed here

FAQ 2013-06-13

Replacement of Control XTP, Module Control Card
Frequently Asked Questions about XTPA Module Control Card

FAQ 2013-06-11

Can I use the MXA or PXA real-time Frequency Mask Trigger (FMT) to provide a trigger output that can be used to trigger another device?
Yes, you can configure the MXA or PXA to provide a trigger output when using FMT.

FAQ 2013-06-05

Can I use option RT1 or RT2 real-time spectrum analyzer in my N9030A PXA that has option B40 installed?
No, you will need to add either option B85 or B1X, depending on the desired analysis bandwidth to your PXA.

FAQ 2013-06-05

What are the specifications for real-time analysis bandwidths on N9030A PXA signal analyzers with option RT1 or RT2?
See details...

FAQ 2013-06-05

Why is option MPB required at frequencies above 3.6 GHz for real-time spectrum analysis in an X-Series signal analyzer?
At frequencies above 3.6 GHz, a YIG Preselector (a tracking band-pass filter) is used to reject out-of-band signals. This filter’s bandwidth is significantly less than 85 or 160 MHz so it must be bypassed if the user wishes to utilize the full 85 or 160 MHz of real-time bandwidth in their PXA.

FAQ 2013-06-05

How can we make VCO/PLL settling time measurements without a frequency vs. time display in the MXA or PXA with options RT1 or RT2 RTSA?
Many PLL/VCO settling time measurements do not really require real-time, they can be made using the spectrogram and with 89600 VSA software.

FAQ 2013-06-05

Can I get the real-time I/Q samples out via LAN on my MXA or PXA signal analyzer with option RT1 or RT2?
No, however you can save the real-time trace (Frequency & Amplitude) data into a .csv file from the spectrogram trace (10,000) traces.

FAQ 2013-06-05

Why is option B85 or B1X required for real-time spectrum analyzer on an MXA or PXA signal analyzer?
All the real-time processing takes place in the option B85 or B1X hardware.

FAQ 2013-06-05

I am looking at a 160 MHz OFDM signal at 5 GHz on my MXA or PXA signal analyzer. Why can’t I see the whole signal?
The instrument preselector is limiting the bandwidth of the MXA or PXA input.

FAQ 2013-06-05

How can I tell if my instrument is licensed for options B1X, B1Y, and MPB?
You can check to see what options are installed in your instrument by pressing the [System] hard key, then the {Show} soft key, then the {System} soft key.

FAQ 2013-06-05

What features will my MXA or PXA signal analyzer have after I install option RT2 or RT1 real-time spectrum analyzer?
Frequency mask trigger, power vs. time measurements, real-time spectrogram, trace zoom peak, average, sample, and negative peak detectors...

FAQ 2013-06-05

How can I perform the calibration/compensation when I use the 16094A with a 7-mm connector extension cable?
It is recommended to perform the following compensation procedure...

FAQ 2013-06-05

How do I upgrade my N9030A PXA Signal Analyzer?
Find Information on Hardware Upgrades, Instrument Software and Measurement Applications, etc....

FAQ 2013-06-04

What upgrade kit option provides real-time functionality for my N9030A PXA signal analyzer?
If you already have option B1X, B1Y, and MPB in your instrument, order N9030AK-RT2 or N9030AK-RT1...

FAQ 2013-06-02

Infiniium Oscilloscopes: Mouse and Trackball Usage
What type of mouse can be used with the Infiniium oscilloscope? Can a trackball device be used?

FAQ 2013-05-31

Infiniium Oscillscopes: Trigger Setup for Violation Mode
When triggering on a setup time violation, what would cause a trigger to occur on a setup time value that is larger than specified?

FAQ 2013-05-31

Infiniium Oscilloscopes: Waveform Labeling
Is it possible to label waveforms?

FAQ 2013-05-31

How do I upgrade my 53200 Series Frequency Counter?
Find Information on Hardware Upgrades, Instrument Software, etc....

FAQ 2013-05-23