My simulation software is failing to import Touchstone files with extensions *.s1, *.s2, etc. Is there a way to rectify this issue?
FAQ
2011-10-07
|
|
|
Can I hide the softkey menu when I perform "Dump Screen Image" on the ENA / ENA-L?
Yes.
FAQ
2011-10-07
|
|
|
Windows login process appears on my ENA every time after power up. Can I skip this?
Yes.
FAQ
2011-10-07
|
|
|
Is there an error in the delay/thru definition for the 85039B F-Type Calibration Kit?
Yes.
FAQ
2011-10-07
|
|
|
Can I disable the front keys, keyboard, mouse and/or touch screen on the ENA / ENA-L?
Yes.
FAQ
2011-10-07
|
|
|
Is it possible to measure the velocity of propagation utilizing an Agilent Vector Network Analyzer (VNA)?
Agilent VNAs do not directly provide the velocity of propagation measurement. As an alternative the steps below outline a method to calculate the velocity of propagation based upon the physical length of the cable under test.
FAQ
2011-10-07
|
|
|
On the ENA, how can I make CW sweep (Fixed frequency) without turning off the ENA's output signal each time a sweep finishes?
Turn off the "Init Src Ctrl" feature, then hold trigger.
FAQ
2011-10-07
|
|
|
Are the adapters in the 85033E 30kHz to 9GHz calibration kit phase matched?
Yes.
FAQ
2011-10-07
|
|
|
On the ENA / ENA-L, it appears as though only the first channel is activated. Is this normal?
Yes
FAQ
2011-10-07
|
|
|
The "set Zo" function does not appear to affect the displayed S-parameters of my network analyzer. How does this function work?
FAQ
2011-10-07
|
|
|
On the ENA / ENA-L, how do I determine my hard disk version?
FAQ
2011-10-07
|
|
|
Are there equation examples for ENA Equation Editor?
Yes.
FAQ
2011-10-07
|
|
|
On the ENA / ENA-L, what is the meaning of "1.#QNB" or "1.#QNAN"?
FAQ
2011-10-07
|
|
|
What are the equations that relate Real and Imaginary data pairs to Log Magnitude, Polar, Phase, and Smith Chart formats?
FAQ
2011-10-07
|
|
|
After performing a calibration with a user defined calibration kit, all log magnitude data is displayed as -200 dB; why?
FAQ
2011-10-07
|
|
|
What are the benefits of the built-in VBA?
FAQ
2011-10-07
|
|
|
On the ENA / ENA-L, the "Update Firmware" key is not displayed under the Service menu. What is wrong?
FAQ
2011-10-07
|
|
|
In limit line test, the marker value at that point is beyond the limit line. However, the Pass/Fail indicates a Pass condition. Why?
FAQ
2011-10-07
|
|
|
Can I modify the trace background color from black to white on the ENA / ENA-L?
FAQ
2011-10-07
|
|
|
On the ENA / ENA-L, when recalling a state, the free running trigger condition is not being preserved. Why?
If the user selects either Save Type "State & Trace" or Save Type "All" then trace data is included as part of the state save.
FAQ
2011-10-07
|
|
|
Why i can't find other languages help file setting in U160X A/B series HH oscilloscope?
In order to access to other language, please go to respective product support page in www.Agilent.com. Go to Driver & Software page, select Firmware Update.
FAQ
2011-09-12
|
|
|
Can I adjust the output voltage of the Arbitrary waveform generator to reduce the broadband noise of the I/Q modulation chain?
It is possible to adjust the output voltage by clicking the advanced menu in pattern details and then un-checking the Auto Output Voltage.
FAQ
2011-09-06
|
|
|
How do you clear the M9202A PXI Express 12-bit Wideband IF Digitizer memory?
FAQ
2011-08-18
|
|
|
Is There a GPS Receiver for FieldFox?
GPS capability has been added to FieldFox starting from firmware revision A.05.33.
FAQ
2011-08-17
|
|
|
Eight commonly asked questions about the Medalist i3070 Series 5
The i3070 Series 5 sports various innovative hardware and software features to bring you much wider test coverage and superb throughput for cost savings and faster time to profit. Check out these key features.
FAQ
2011-08-08
|
|