Technical Support
Spectrum Analyzers (Signal Analyzers)
Refine the List
By Topic
-
All Topics
- Operation & Functionality
By Type of Content
-
FAQs
- FAQ
By Product Category
-
Spectrum Analyzers (Signal Analyzers)
-
FieldFox and HSA Handheld Spectrum Analyzers
- N9344C Handheld Spectrum Analyzer (HSA), 20 GHz (15)
- N9343C Handheld Spectrum Analyzer (HSA), 13.6 GHz (15)
- N9342C Handheld Spectrum Analyzer (HSA), 7 GHz (15)
- N9340B Handheld Spectrum Analyzer (HSA), 3 GHz (13)
- N9935A FieldFox Handheld Microwave Spectrum Analyzer, 9 GHz (10)
- N9936A FieldFox Handheld Microwave Spectrum Analyzer, 14 GHz (10)
- N9937A FieldFox Handheld Microwave Spectrum Analyzer, 18 GHz (10)
- N9938A FieldFox Handheld Microwave Spectrum Analyzer, 26.5 GHz (9)
- N9917A FieldFox Handheld Microwave Combination Analyzer, 18 GHz (10)
- N9918A FieldFox Handheld Microwave Combination Analyzer, 26.5 GHz (9)
- N9912A FieldFox Handheld RF Combination Analyzer, 4 and 6 GHz (9)
- N9913A FieldFox Handheld RF Combination Analyzer, 4 GHz (10)
- N9914A FieldFox Handheld RF Combination Analyzer, 6.5 GHz (10)
- N9915A FieldFox Handheld Microwave Combination Analyzer, 9 GHz (10)
- N9916A FieldFox Handheld Microwave Combination Analyzer, 14 GHz (10)
-
FieldFox and HSA Handheld Spectrum Analyzers
1-25 of 26
|
Can I use an Agilent 85032E Cal Kit with FieldFox instruments?
Yes. You can use an 85032E Cal kit with FieldFox.
FAQ 2012-08-20 |
|
|
Are there limit lines with pass/fail status on FieldFox instruments?
Yes, all the modes include limit lines and pass/fail status indicators.
FAQ 2012-08-20 |
|
|
Is it possible to modify the scale on the return loss plot when the measurement is configured for Return Loss & DTF on a FieldFox instrument?
There is no method to change the scale on the upper Return Loss (top) plot.
FAQ 2012-08-20 |
|
|
Will FieldFox instruments be able to differentiate between internal and external zeroing when using the U200xA/B/H USB power sensors?
FieldFox instruments cannot do this differentiation, but FieldFox allows you the choice of external zeroing.
FAQ 2012-08-20 |
|
|
How Can I Find What I Need in a Signal Analyzer Recording Faster?
If you have a very long Signal Analyzer recording, it is sometimes difficult to find the area of interest. There is no really good tool for this problem at this time, but here are some suggestions.
FAQ 2012-08-17 |
|
|
FieldFox will not recognize my USB memory stick. What can I do?
Most USB memory sticks work well with the FieldFox.
FAQ 2012-08-17 |
|
|
Which is Most Accurate: CalReady, QuickCal (Without Load), or 2 Port Calibration?
When nothing connected at the end of RF port, CalReady is the most accurate calibration method at test port.
FAQ 2012-08-15 |
|
|
Why won't my Signal Analyzers Display Pulse Type Signals Properly?
These signals may be missed if the Sweep Acquisition setting is on Auto. We recommend using a Sweep Acquisition setting of 50 or 100 for GSM signals.
FAQ 2012-08-15 |
|
|
Will the handheld spectrum analyzers have an LXI C class (web server)?
No, there is no plan for an LXI C class (web server).
FAQ 2012-03-02 |
|
|
How can I make field strength measurements on my handheld spectrum analyzer?
Each of the HSA products supports field strength measurements.
FAQ 2012-03-02 |
|
|
Are the remote control commands of the handheld spectrum analyzers compatible with any other instrument?
The remote control command set of the handheld spectrum analyzers is compatible with the command sets of other spectrum analyzers.
FAQ 2012-03-02 |
|
|
Do the handheld spectrum analyzers offer a tracking generator?
Yes, all HSA models have a tracking generator option.
FAQ 2012-03-01 |
|
|
What is the Task Planner Trial program?
A program offered by Agilent that allows customers to obtain a 90-day trial license.
FAQ 2012-02-22 |
|
|
Why Do I Get a "VCO Unlock Error" on my N9923A?
The solution is to upgrade firmware to A.05.04 or later.
FAQ 2011-11-14 |
|
|
Can I measure VSWR, return loss and DTF with my handheld spectrum analyzer?
The HSAs do not provide a read-out of VSWR or DTF.
FAQ 2011-11-11 |
|
|
Do the handheld spectrum analyzers have AM/FM demodulation?
Yes
FAQ 2011-11-11 |
|
|
How do I enable the GPS information on the handheld spectrum analyzer?
The steps to enable GPS on the N9342C, N9343C or N9344C are: Press[Shift] -> [System Mode] -> {More 1 of 2} -> {GPS} -> {GPS on} and {GPS Info on}.
FAQ 2011-11-10 |
|
|
Can the handheld spectrum analyzers be turned on or off remotely?
There is no SCPI command to turn the HSA on or off remotely.
FAQ 2011-11-10 |
|
|
How long will a handheld spectrum analyzer powered by battery continuously work?
A battery-powered HSA can continuously work for a minimum of 3 hours.
FAQ 2011-11-10 |
|
|
Do the handheld spectrum analyzers have record/playback features in the spectrogram and the spectrum mode? Can the signal be recorded on a USB drive?
Option SIM for the HSAs provides record and playback features in the spectrogram and the spectrum mode.
FAQ 2011-11-07 |
|
|
Is it possible to operate the power meter option (PWM) remotely using a SCPI command?
No, the power meter option on the HSAs cannot be controlled remotely.
FAQ 2011-11-07 |
|
|
Is it possible to load built-in cellular frequency channels onto the handheld spectrum analyzer?
Yes, each HSA model allows the user to load standard frequency channels, like GSM or W-CDMA.
FAQ 2011-11-07 |
|
|
Does the user interface of the handheld spectrum analyzer support multiple languages?
Yes, the user interface for each of the HSA models supports eleven languages.
FAQ 2011-11-03 |
|
|
Do the handheld spectrum analyzers have a keystroke recorder?
No, the HSAs do have a keystroke recorder.
FAQ 2011-11-03 |
|
|
Is There a GPS Receiver for FieldFox?
GPS capability has been added to FieldFox starting from firmware revision A.05.33.
FAQ 2011-08-17 |
|