What is the maximum distance allowed between a host computer and USB Data Acquisition (DAQ) devices?
According to USB specifications, the maximum distance allowed between a host computer and USB Data Acquisition (DAQ) device is five meters.

FAQ 2008-09-25

Can the U2802A Thermocouple input device work with all the USB Data Acquisition (DAQ) models?
No. The U2802A Thermocouple input device can only be used with the U2355A or U2356A USB data acqusition (DAQ) model.

FAQ 2008-09-25

Does the Agilent Measurement Manager (AMM) run on a Linux operating system?
No, the Agilent Measurement Manager (AMM) does not run on a Linux operating system.

FAQ 2008-09-25

What is the required operating system for the U2300A Series Modular Multifunction Data Acquisition (DAQ) devices?
The operating system required for the U2300A Series Modular Multifunction Data Acquisition (DAQ) devices is….

FAQ 2008-09-25

What is the maximum torque force allowable on the 82350B GPIB card connector?
The maximum torque force allowable when attaching a GPIB cable to the 82350B GPIB card connector is 8 in. lbs.

FAQ 2008-09-24

Can the Agilent Measurement Manager (AMM) application software be used to control all six USB Data Acquisition (DAQ) devices in a modular chassis?
Yes, the Agilent Measurement Manager (AMM) can be configured to control all USB Data Acquisition (DAQ) devices in the chassis.

FAQ 2008-09-24

Can the U2300A/U2500A Series Data Acquisition (DAQ) devices that are used with three modular chassis be synchronized?
Yes, the U2300A and U2500A Series Data Acquisition (DAQ) devices that are used with three modular chassis can be synchronized….

FAQ 2008-09-24

What is the expected transfer rate over the U2781A USB Modular Instrument Chassis?
The transfer rate of the U2781 is dependent on the type of USB Data Acquisition (DAQ) Modules installed and the number of channel counts….

FAQ 2008-09-24

Why should I use the U2802A Thermocouple input device?
The U2802A Thermocouple input device offers you a complete temperature measurement solution when used with data acquisition (DAQ) devices….

FAQ 2008-09-24

Can the Agilent Measurement Manager (AMM) display multiple U2781A modular chassis on the same application window?
No, the Agilent Measurement Manager (AMM) can only display one U2781A modular chassis on one application window…

FAQ 2008-09-24

What are the drivers needed to run the U2300A Series Data Acquisition (DAQ) devices with LabView?
The IVI-COM driver is required for the U2300A Series Data Acquisition (DAQ) devices to work with LabView.

FAQ 2008-09-24

Can the U2531A/U2541A/U2542A Data Acquisiton device work in both Single-Ended and Differential mode?
No, the U2531A, U2541A and U2542A Data Acquisiton devices cannot work in both Single-Ended and Differential mode….

FAQ 2008-09-24

How many U2781A modular chassis can be connected via USB at the same time?
USB has a limit of 127 device connections. Theoretically, about 18 chassis can be connected at a time.

FAQ 2008-09-24

Where can I get the terminal pin configuration for each model of the U2300A Series USB Data Acquisition (DAQ) devices?
The terminal pin configuration for each model of the U2300A Series USB Data Acquisition (DAQ) devices can be found in the User’s Guide….

FAQ 2008-09-24

What are the maximum sampling rates for the U2531A, U2541A and U2542A Data Acquisition (DAQ) devices?
The maximum sampling rates for the U2531A, U2541A and U2542A Data Acquisition (DAQ) devices are:….

FAQ 2008-09-24

When using the U2300A Series DAQ devices, how many channels can the Agilent Measurement Manager (AMM) display?
The Agilent Measurement Manager (AMM) can display all 16 or 64 channels depending on the model of the U2300A Series DAQ device selected….

FAQ 2008-09-24

What programming platforms are compatible with the U2300A Series Data Acquisition (DAQ) devices?
Agilent VEE, LabView, Microsoft Visual Studio and C++ are compatible with the U2300A Series Data Acquisition (DAQ) devices.

FAQ 2008-09-24

Which thermocouple types are compatible with the U2802A Thermocouple input device?
Eight standard thermocouple types defined in the NIST ITS-90 Thermocouple Database are compatible with the U2802A input device….

FAQ 2008-09-24

Are there any sample programs provided for the U2300A and U2500A Series Data Acquisition (DAQ) devices?
Yes, sample programs of VEE, LabView and Microsoft® Visual Studio® are available for the U2300A and U2500A Series Data Acquisition (DAQ)….

FAQ 2008-09-24

Is calibration required for the U2651A/U2652A/U2653A Digital I/O device?
No, calibration is not required for the U2651A, U2652A and U2653A Digital I/O devices.

FAQ 2008-09-24

How do I connect external sensors to the U2300A Series Data Acquisition (DAQ) devices?
External sensors can be connected to the U2300A Series Data Acquisition (DAQ) devices through the U2901A or U2902A terminal block….

FAQ 2008-09-24

How do I connect the 33210A or 33220A to a PC via the USB port?
Install IO Libraries. Connect instrument. When prompted select “display a list of known drivers…”

FAQ 2008-09-01

Can I close all of the channels in the reed cards (ie. 34923A, 34924A, and 34933A) at the same time when working in switch mode?
No. Due to power dissipation, you cannot close all of the channels in the reed cards simultaneously when working in switch mode.

FAQ 2008-08-15

Can I Perform Open/Short Test Using 34980A?
Yes. There are two ways you can setup using the 34980A to perform this test.

FAQ 2008-06-25

Can Agilent build my custom L4490A/L4491A solution?
Please visit "www.agilent.com/find/AD-systems" or see Agilent’s Channel Partners and Solution Providers at "www.agilent.com/find/channelpartner"

FAQ 2008-04-07