Discutez avec un expert

Support technique

Test et mesure électronique

Recherche par numéro de modèle du produit: Exemples : 34401A, E4440A

Affiner la liste

Par sujet

Par application

Par type de contenu

Par catégorie de produit

1-25 sur 7736

Sort:
Explore the Newest Release of ADS and More
List of product-specific release information for Advanced Design System

FAQ 2013-06-17

What hardware platforms are supported by the 89600 VSA and 89600 WLA Software?
The measurement hardware front ends include supported by the current version of software are listed here.

FAQ 2013-06-14

Upgrading 89600 VSA Software
Adding new options, upgrading to new revisions, and adding additional applications is described in this document.

FAQ 2013-06-13

89600 VSA software and X-Series signal analyzer software compatibility matrix
Supported versions listed here

FAQ 2013-06-13

How do I upgrade my E8257D PSG Analog Signal Generator?
Find Information on Hardware Upgrades, Instrument Software, etc....

FAQ 2013-06-11

Where can I find manuals for discontinued and obsolete Hewlett-Packard and Agilent test equipment?
Most Agilent products have PDF manuals that can be found on product pages. Other vendors also supply old manuals.

FAQ 2013-06-10

Signal Generator Firmware Update Center
Download signal generator firmware, release notes, upgrade guide and FAQs.

FAQ 2013-06-07

Agilent Infiniium Software Update Utility
Utilities for assessing and updating your Infiniium software.

FAQ 2013-06-06

Why is option B85 or B1X required for real-time spectrum analyzer on an MXA or PXA signal analyzer?
All the real-time processing takes place in the option B85 or B1X hardware.

FAQ 2013-06-05

How can I perform the calibration/compensation when I use the 16094A with a 7-mm connector extension cable?
It is recommended to perform the following compensation procedure...

FAQ 2013-06-05

Can I use option RT1 or RT2 real-time spectrum analyzer in my N9030A PXA that has option B40 installed?
No, you will need to add either option B85 or B1X, depending on the desired analysis bandwidth to your PXA.

FAQ 2013-06-05

How can I tell if my instrument is licensed for options B1X, B1Y, and MPB?
You can check to see what options are installed in your instrument by pressing the [System] hard key, then the {Show} soft key, then the {System} soft key.

FAQ 2013-06-05

I am looking at a 160 MHz OFDM signal at 5 GHz on my MXA or PXA signal analyzer. Why can’t I see the whole signal?
The instrument preselector is limiting the bandwidth of the MXA or PXA input.

FAQ 2013-06-05

What are the specifications for real-time analysis bandwidths on N9030A PXA signal analyzers with option RT1 or RT2?
See details...

FAQ 2013-06-05

Why is option MPB required at frequencies above 3.6 GHz for real-time spectrum analysis in an X-Series signal analyzer?
At frequencies above 3.6 GHz, a YIG Preselector (a tracking band-pass filter) is used to reject out-of-band signals. This filter’s bandwidth is significantly less than 85 or 160 MHz so it must be bypassed if the user wishes to utilize the full 85 or 160 MHz of real-time bandwidth in their PXA.

FAQ 2013-06-05

What is the replacement of the discontinued fixtures/accessories for LCR meters/Impedance Analyzer?
The part which is identical with its product is available.

FAQ 2013-06-05

What features will my MXA or PXA signal analyzer have after I install option RT2 or RT1 real-time spectrum analyzer?
Frequency mask trigger, power vs. time measurements, real-time spectrogram, trace zoom peak, average, sample, and negative peak detectors...

FAQ 2013-06-05

How can we make VCO/PLL settling time measurements without a frequency vs. time display in the MXA or PXA with options RT1 or RT2 RTSA?
Many PLL/VCO settling time measurements do not really require real-time, they can be made using the spectrogram and with 89600 VSA software.

FAQ 2013-06-05

Infiniium 90000 and 9000 Series Oscilloscope Software
Infiniium 90000 and 9000 Series oscilloscope software.

FAQ 2013-06-05

How do I upgrade my N9010A EXA Signal Analyzer?
Find Information on Hardware Options, Measurement Applications, etc....

FAQ 2013-06-05

Can I use the MXA or PXA real-time Frequency Mask Trigger (FMT) to provide a trigger output that can be used to trigger another device?
Yes, you can configure the MXA or PXA to provide a trigger output when using FMT.

FAQ 2013-06-05

How do I upgrade my N9020A MXA Signal Analyzer?
Find Information on Hardware Options, Measurement Applications, etc....

FAQ 2013-06-05

Can I get the real-time I/Q samples out via LAN on my MXA or PXA signal analyzer with option RT1 or RT2?
No, however you can save the real-time trace (Frequency & Amplitude) data into a .csv file from the spectrogram trace (10,000) traces.

FAQ 2013-06-05

How do I upgrade my N9030A PXA Signal Analyzer?
Find Information on Hardware Upgrades, Instrument Software and Measurement Applications, etc....

FAQ 2013-06-04

LTE-Advanced FDD/TDD Signal Generation and Analysis
Agilent addresses LTE-Advanced challenges by providing the industry'sfirst signal generation & analysis tools, enabling design engineers to test physical layer implementations,now with envelope tracking capability, with greater insight & confidence.

FAQ 2013-06-04

1 2 3 4 5 6 7 8 9 10 ... Page suivante