Sprechen Sie mit einem Experten
Technischer Support
Test & Messtechnik
Refine the List
Alle detailierte Suchkriterien entfernen
Nach Oberbegriff
- Calibration (4)
- Configuration & Installation (21)
- Display Messages/Error Codes (4)
- Licensing (1)
- Measurement Techniques (2)
- Operating System & Software (5)
- Operation & Functionality (39)
- Other Information (6)
- Product Theory of Operation (8)
- Programming & Data Transfer (12)
- Service & Maintenance (2)
- Specifications & Accuracy (24)
- Troubleshooting (2)
By Type of Content
Nach Produkt Kategorie
-
Alle Produkt Kategorien
-
Generators, Sources, Supplies
-
DC Power Supplies
- 0-50W, DC Power Supplies, GPIB, Single and Multiple Outputs (91)
- 51-175W, DC Power Supplies, GPIB, Single and Multiple Outputs (37)
- 176-1200W, DC Power Supplies, GPIB, Single and Multiple Output (43)
- 200-2000W, DC Power Supplies, no Interface, Single Output (19)
- 1201-6600W, DC Power Supplies, GPIB, Single Output (27)
- Single and Multiple Output Bench Power Supplies (39)
- Application Specific Power Supplies (39)
-
DC Power Supplies
-
Generators, Sources, Supplies
1-25 of 127
|
How can I find the low terminal state of the channels on the B2961A/B2962A?
If the low terminal state of the channel is set to FLOATING, you can see the status indicator on GUI.
FAQ 2013-03-11 |
|
|
Can B2961A/B2962A connect its output to the ground when the output is switched off?
Yes, the B2961A/B2962A can connect its output to the ground by specifying the output-off state to "ZERO" when the output is switched off.
FAQ 2013-03-11 |
|
|
How can I find the power-on state setting of the B2961A/B2962A?
You can find the power-on state setting on the System Start-up dialog box.
Click the above link for details.
FAQ 2013-03-11 |
|
|
How can I perform a self calibration on B2961AB2962A?
Click the above link for details.
FAQ 2013-03-11 |
|
|
The Agilent B2961A/B2962A shows the message "Interlock terminal is open" and don't accept to input voltage more than 42 V.
Click the above link for details.
FAQ 2013-03-11 |
|
|
Can I set the different limit values for each of polarities on the B2961A/B2962A?
Yes, it's possible by enabling V/I Limit for Each Polarity.
Click the above link for details.
FAQ 2013-03-11 |
|
|
How to configure the time constant of the output filter with the B2961A/B2962A?
The time constant of the output filter can be configured on the Output Filter dialog box.
Click the above link for details.
FAQ 2013-03-11 |
|
|
How can I enable Over Voltage/Current Protection function on the B2961A/B2962A?
Click the above link for details.
FAQ 2013-03-11 |
|
|
How can I set up Power-on State of the B2961A/B2962A?
It is possible to store the desired instrument condition as Power-on State.
Click the above link for details.
FAQ 2013-03-11 |
|
|
What kind of interface can I use to control the B2961A/62A?
The GPIB, USB and LAN are available to control the B2961A/62A.
FAQ 2013-03-11 |
|
|
How can I save or load the measurement setups on the B2961A/B2962A?
Click the above link for details.
FAQ 2013-03-11 |
|
|
How can I find the sensing type of the channels on the B2961A/B2962A?
If the low terminal state of the channel is set to FLOATING, you can see the status indicator on GUI.
FAQ 2013-03-11 |
|
|
I can't source as low noise signal as expected from the B2961A/B2962A with the Ultra Low Noise Filter.
Click the above link for details.
FAQ 2013-03-11 |
|
|
How can I find the power-on program setting of the B2961A/B2962A?
You can find the power-on program setting on the System Start-up dialog box.
Click the above link for details.
FAQ 2013-03-11 |
|
|
Can the B2961A/B2962A step the source value immediately after the value is changed by its rotary knob?
Yes, it's possible by enabiling Immediate V/I Update function.
Click the above link for details.
FAQ 2013-03-11 |
|
|
Where can I get LabVIEW Plug and Play Instrument Driver for B2961A/B2962A?
You can get LabVIEW Plug and Play Instrument Driver for B2961A/B2962A from NI.com.
FAQ 2013-03-11 |
|
|
Quick I/V Measurement Software cannot recognize the B2961A/B2962A.
The B2961A/B2962A is supported by Quick I/V Measurement Software in the revision 2.0 or later.
Click the above link for details.
FAQ 2013-03-11 |
|
|
How can I update its firmware on the B2961A/B2962A?
Click the above link for details.
FAQ 2013-03-11 |
|
|
How can I configure Trigger Output Signals with the B2961A/B2962A?
Click the above link for details.
FAQ 2013-03-11 |
|
|
I can't source as low noise signal as expected from the B2961A/B2962A with the Low Noise Filter.
Click the above link for details.
FAQ 2013-03-11 |
|
|
Can I upgrade from B2961A to B2962A?
No, you cannot upgrade from B2961A to B2962A.
FAQ 2013-03-11 |
|
|
Is it possible to append the data to the previous one in Graph View?
No.
FAQ 2012-12-30 |
|
|
How do I find my Agilent B2961A/B2962A firmware revision?
You can find the firmware revision on the Revision dialog box.
FAQ 2012-12-30 |
|
|
66xxA, E363xA and E364xA: Can Agilent Power Supplies Sink Current?
Yes! Sinking, or down-programming, is the ability to pull current into the positive terminal of a power supply.
FAQ 2012-12-07 |
|
|
How can I source a ramp waveform on the B2961A/B2962A?
Click the above link for details.
FAQ 2012-11-22 |
|