Will Windows 7 work on my existing processor?
There is a minimum configuration/vintage of processors which are compatible with Windows 7 and these are denoted as PC4 and PC5 in the show system screen on your instrument
FAQ 2013-04-25 |
|
|
How can an installed base customer with Windows XP Professional for Embedded Systems upgrade to Windows Embedded Standard 7?
For the PC4/PC5 processor, the upgrade is via the software kit on Option SSD. For older CPUs, the CPU hardware must first be upgraded to PC4/PC5.
FAQ 2013-04-25 |
|
|
How long will Agilent support Windows XP Professional for Embedded Systems?
Windows XP will be supported until May 2016.
FAQ 2013-04-25 |
|
|
What if I need secure scripts to utilize Windows 7 within my secure measurement lab?
Agilent will work with you to evaluate scripts we have developed and successfully deployed in other secure measurement labs.
FAQ 2013-04-25 |
|
|
For installed-base customers, after purchasing the N9094AK-PC4 or N9094AK-SSD option, must the instrument to a local SSU office for upgrading?
No. The N9094AK-PC4 and N9094AK-SSD upgrade options come with an imaged SSD.
FAQ 2013-04-25 |
|
|
Will I be able to continue to get defect fixes if I remain on Windows XP?
We will continue to maintain the last shipping Windows XP version through end of support life.
FAQ 2013-04-25 |
|
|
FieldFox – 펌웨어
최신 펌웨어 업데이트 다운로드...
이전 버전
계측기 펌웨어/소프트웨어 현재 버전:A.06.23 | 2013-04-25 |
|
|
Replacing the 8508A vector voltmeter with the E5061B network analyzer
Measuring the phase difference of an external CW signals is a typical measurement application of the 8508A vector voltmeter.
FAQ 2013-04-25 |
|
|
How do I know what operating system my instrument will have?
Your quote and order will indicate the operating system.
FAQ 2013-04-25 |
|
|
ENA 6 시리즈는 주파수 스윕할 때 swept sweep 모드를 지원합니까?
아니요..
FAQ 2013-04-25 |
|
|
M1970V과 M1970W 스마트 믹서의 waveguide flange 타입은 무엇입니까?
기존의 11970V 와 11970W 하모닉 믹서와 동일합니다.
FAQ 2013-04-25 |
|
|
8x8 MIMO and Carrier Aggregation Test Challenges for LTE Webcast Slides
Slides from the April 25, 2013 webcast
세미나 프리젠테이션 2013-04-25 |
|
|
Which 89600 VSA version is supported by firmware release A.12.xx on Windows 7?
All 89601B versions should work with firmware release A.12 for Windows 7.
FAQ 2013-04-25 |
|
|
Will Agilent continue to sell existing functionality/upgrades for my instruments?
We have no plans to end upgrade offerings for existing Windows XP functionality
FAQ 2013-04-25 |
|
|
Will I be able to get all future minor enhancements if I remain on Windows XP?
When we stop selling Windows XP downgrades we will end enhancing Windows XP SW versions.
FAQ 2013-04-25 |
|
|
Why is Agilent delivering OS upgrades on the Option SSD or Option PC4/PC5 processor?
Agilent’s licensing agreement prevents us from selling the operating system independent of physical hardware.
FAQ 2013-04-25 |
|
|
How do I remotely manage the internal alignments on my X-Series Signal Analyzer?
This example demontrates the "cal:expired?" and "cal:auto:part" commands to handle running internal alignments remotely
FAQ 2013-04-25 |
|
|
Is the firmware revision A.12.xx installer the same for both Windows XP and Windows 7?
Firmware revision A.12.xx installer for Windows XP is a separate file than the firmware revision A.12.xx installer for Windows 7. Both are available on the Download button for the instrument software.
FAQ 2013-04-25 |
|
|
FieldFox – 펌웨어 아카이브
N9912A 및 N9923A에 대한 전체 펌웨어 개정판 목록
이전 버전
계측기 펌웨어/소프트웨어 현재 버전:A.06.23 | 2013-04-25 |
|
|
E5071C-TDR Method of Implementation (MOI) for High Speed Digital Applications
FAQ 2013-04-25 |
|
|
How can I bundle N1045A remote heads together in a tight space?
For simple differential setups, two heads can simply be clipped together using the supplied clip. To mount more heads see the full body of this FAQ for mounting dimensions and thermal considerations.
FAQ 2013-04-24 |
|
|
Sample Setups and Test Results for the Step by Step Measurement Handbook of IGBT
Setups and test results of measurements introduced in the step by step measurement handbook of IGBT.
프로그램 예제 2013-04-24 |
|
|
[Method of Implementation] HDMI Cable Assembly Compliance Test
프로그램 예제 2013-04-24 |
|
|
Analyze Agile or Elusive Signals Using Real-time Measurement and Triggering Webcast Slides
Slides from the April 24, 2013 webcast
세미나 프리젠테이션 2013-04-24 |
|
|
How do I poll to determine when the internal alignments are complete on my X-Series or PSA Series Signal Analyzer
Programming example to demonstrate how to poll the status register for operation complete
FAQ 2013-04-23 |
|