DSO91304A Infiniium High Performance Oscilloscope: 13 GHz
| Sold By: |
|
|---|
Base Price GBP 86,263
Typically Configured Price GBP 86,736
Typical Configuration
DSO91304A Infiniium Oscilloscope - 13 GHz, 40 GSa/s, 4 Ch
- DSO90000A-805 GPIB card-interface - installed
- DSO90000A-800 Standard hard drive - installed
- DSO90000A-821 Additional Precision BNC to SMA adapters includes qty 2
- R-51B-001-3C Return to Agilent Warranty - 3 years
Typically Configured Price GBP 86,736
Prices for: United Kingdom
* Prices are subject to change without notice. Prices shown are Manufacturer's Suggested Retail Prices (MSRP).
Refine the List
By Type of Content
- Specifications (16)
- Manuals (7)
- Application Notes (30)
- Brochures & Competitive Overviews (5)
- Demos (1)
- Articles & Case Studies (1)
1-25 of 60
| User's Guides, Programmer's Guides, and Online Help (Version 04.30.0009)
This installer places an "Agilent Infiniium Docs" folder shortcut on your desktop. In this folder you can find user's guides, programmer's guides, and other manuals that go with Infiniium 90000 Series and 9000 Series oscilloscope system software.
Help File 2013-05-15 |
|
| USB 2.0 Compliance Testing with Infiniium Oscilloscopes - Application Note
This Application Note discusses the Agilent solution for the USB 2.0 test suite. The Agilent solution is the only one-box solution that uses the official USB-IF scripts for precompliance ans compliance testing.
Application Note 2013-05-10 |
|
| Using Microwave Switches When Testing High Speed Serial Digital Interfaces - Application Note
Many high speed digital interfaces use multiple lanes to achieve their system's throughput requirements. Most issues associated with this can be resolved with a switching network.
Application Note 2013-05-07 |
|
| User's Guides, Programmer's Guides, and Online Help (Version 04.20.0005)
This installer places an "Agilent Infiniium Docs" folder shortcut on your desktop. In this folder you can find user's guides, programmer's guides, and other manuals that go with Infiniium 90000 Series and 9000 Series oscilloscope system software.
Help File 2013-05-06 |
|
| N5435A Infiniium Server-Based License for Infiniium Oscilloscopes - Data Sheet
The Agilent N5435A Infiniium server-based license allows you to move your oscilloscope application license from one Infiniium oscilloscope to another, using a license server.
Data Sheet 2013-05-02 |
|
| Infiniium 90000 Series Oscilloscopes - Data Sheet
Infiniium 90000A Series scopes provide the solution for all high-speed digital and RF design engineers evaluating signal integrity, validating compliance, and analyzing and debugging designs.
Data Sheet 2013-04-01 |
|
| Programmer's Reference for Infiniium 90000A/90000X Series Oscilloscopes
This is a zipped Microsoft Windows® format help file. Extract this file to a Local Disk (a Windows security requirement); on Windows XP, you may have to open the file's Properties dialog and Unblock the file before opening.
Programming and Syntax Guide 2013-03-21 |
|
| Programmer's Reference for Infiniium 90000A/90000X Series Oscilloscopes (PDF)
This is a printable PDF version of the Infiniium 90000A/90000X Series Oscilloscopes Programmer's Reference.
Programming and Syntax Guide 2013-03-21 |
|
| N5392A Ethernet Electrical Performance Validation and Compliance Software - Data Sheet
The Agilent Technologies N5392A Ethernet electrical performance validation and compliance software for Infiniium 54830 and 54850 Series oscilloscopes provides you with a fast and easy way to verify and debug your 1000Base-T, 100Base-TX and 10Base-T Ethernet designs. The Ethernet electrical test software
Data Sheet 2013-03-14 |
|
| Three Compelling Reasons for Deep Acquisition Memory
This app note discusses deep memory's value. While acquisition memory depth is often used as a primary purchase consideration, the associated benefits require additional thought to fully appreciate.
Application Note 2013-03-14 |
|
| Evaluating Oscilloscope Fundamentals - Application Note
We will discuss oscilloscope applications and give you an overview of basic measurements and performance characteristics.
Application Note 2013-03-06 |
|
| Infiniium 90000A Series Service Guide
This book provides the service documentation for the Agilent Technologies 90000 Series
oscilloscopes.
Service Manual 2013-03-01 |
|
| EZJIT Plus Jitter Analysis Software for Infiniium Oscilloscopes - Data Sheet
With the faster edge speeds and shrinking data valid windows in today s high-speed digital designs, insight into the causes of signal jitter is critical for ensuring the reliability of your design. Model E2681A EZJIT jitter analysis software from Agilent Technologies, combined with the Infiniium 54830 and 54850 Series oscilloscopes, helps to identify and quantify jitter components. Time correlation of jitter to the real-time signal makes it easy to trace jitter components to their sources.
Data Sheet 2013-02-14 |
|
| E2688A, N5384A High-Speed Serial Data Analysis & Clock Recovery Software for Infiniium Oscilloscopes
The Agilent Technologies E2688A serial data analysis software provides engineers with a fast and easy way to validate signal integrity for serial interface designs. The E2688A, when used with the Agilent 54850 Series Infiniium real-time oscilloscopes, performs mask testing and characterizes serial data streams that employ embedded clocks. The E2688A enables engineers to verify compliance to computer, communication, and data communications standards such as PCI Express, Serial ATA, Fibre Channel, and Gigabit Ethernet.
Data Sheet 2013-01-15 |
|
| Infiniium Oscilloscope Probes and Accessories - Data Sheet
Probes and accessories for Infiniium Series oscilloscopes
Data Sheet 2012-11-26 |
|
| Evaluating Oscilloscope Sample Rates vs. Sampling Fidelity
Evaluating Oscilloscope Sample Rates vs. Sampling Fidelity: How to Make the Most Accurate Digital Measurements When you select an oscilloscope for accurate, high-speed digital measurements, sampling fidelity can often be more important than maximum sample rate.
Application Note 2012-11-11 |
|
| Evaluating Oscilloscope Bandwidths for your Application
This application note provides some helpful hints on how to select an oscilloscope with the appropriate bandwidth for analog and digital applications.
Application Note 2012-11-08 |
|
| Bandwidth and Rise Time Requirements for Making Accurate Oscilloscope Measurements
How much oscilloscope bandwidth do you need and how fast does the rise time need to be to measure your signals accurately?
Application Note 2012-08-17 |
|
| Ten things to Consider when Selecting your Next Oscilloscope - Application Note
You rely on your oscilloscope every day, so selecting the right one to meet your needs is an important task. Comparing specs and features of scopes made by different manufacturers can be time-consuming and confusing. The concepts outlined here are intended to speed your selection process and help you avoid some common pitfalls. No matter who makes the scopes you are considering, carefully analyzing each one in relation to the 10 issues discussed here will help you evaluate the instruments objectively.
Application Note 2012-05-15 |
|
| I2C and SPI Protocol Triggering and Decode for Infiniium 8000 and 90000 Series Oscilloscopes
Extend your scope capability with I2C and SPI Triggering and Decode application. This application makes it easy to debug and test designs that include I2C or SPI protocols using your Infiniium 90000 or 8000 Series scope.
Data Sheet 2012-03-11 |
|
| Understanding The Oscilloscope Jitter Specifi cation
Jitter is defined as the unwanted phase modulation of a digital signal, and is considered one of the most important specifications for measuring a device's quality.
Application Note 2011-09-30 |
|
| Oscilloscopes and ENOB
For scopes with bandwidth in the GHz range, a quality metric involves characterizing the analog-to-digital converter (ADC) using effective number of bits (ENOB). How important is ENOB?
Application Note 2011-08-08 |
|
| Eight Hints for Better Scope Probing
Probing is critical to making quality oscilloscope measurements, and often the probe is the
fi rst link in the oscilloscope measurement chain.
Application Note 2011-05-24 |
|
| Optimizing Oscilloscope Measurement Accuracy on High-Performance Systems with Agilent Active...
To keep high-speed devices supplied with data so they are not sitting idle, designers have been
inventing techniques to increase the bandwidth of external buses in order to move large amounts of
data between devices on circuit boards.
Application Note 2011-05-20 |
|
| An Overview of the Electrical Validation of 10BASE-T, 100BASE-TX, and 1000BASE-T
The technology used in these ports, commonly known as “LAN” or “NIC” ports, is usually one of the 10BASE-T, 100BASE-TX, and 1000BASE-T standards or a combination of them.
Application Note 2011-01-11 |
|
What's New
- 3-year instrument warranty is now standard
- How much can you save by choosing Agilent Technologies as the only service provider?
- Find us on Facebook
- Get a 50% credit when you trade this model toward a new Infiniium oscilloscope
- Get a complimentary DSOX3034A oscilloscope with your purchase of this product until Sept. 30, 2013
