Agilent 10770A Product Photograph

10770A Angular Interferometer

Product Status: Currently Orderable | Currently Supported

click to collapse this panelDescription

The Agilent 10770A Angular Interferometer is a high accuracy plane mirror interferometer ideal for use in precision calibration applications. Used with the 10771A Angular Reflector in an 5529A Dynamic Calibrator system, the interferometer measures pitch and yaw motions along each axis that a machine tool or measuring machine travels. The system can help quickly locate and evaluate unwanted angular motion. The 10770A has a range of up to ±36,000 arc-seconds (±10°) when used with the 10771A Angular Reflector, with 0.1 arc-second resolution and a maximum transmitted beam deviation of ±30 arc-seconds. An alignment target is included to simplify setup.

As part of the 5529A system, the 10770A is a powerful diagnostic tool that helps find the causes of angular positioning errors – information that is critical in making replace or rebuild decisions for older machine tools.

  • Brief description: Interferometer, angular, 1 axis, 6 mm beam
  • Measurements: Rotation (pitch) about the Y axis OR rotation (yaw) about the Z axis
  • Number of axis: 1
  • Beam size: 6 mm
  • Usage: High accuracy
  • Application: Single axis
  • Stability: Medium
  • Measurement Resolution: 0.1 arc-second
  • Range: Up to ±36,000 arc-seconds (±10° when used with the Agilent 10771A Angular Reflector)
  • Maximum transmitted beam deviation: ±30 arc-seconds
  • Optical resolution: Lambda/4 (158.2 nm, 6.2 uin)
  • System resolution (32x): Lambda/64 (10 nm, 0.4 uin) (When used with the Agilent 5527B Laser Positioning System, 10885A PC Axis Board or 10895A Laser Axis Board for VMEbus.)
  • System resolution (256x): Lambda/512 (1.2 nm, 0.047 uin) (When used with the Agilent 10897B, 10897C and 10898A Axis Boards for VMEbus.)
  • Beam separation: 11 mm (0.43 in)
  • Weight: 553 g (19.5 oz)
  • Housing: Stainless steel (416)
  • Apertures: Plastic (Nylon)
  • Optics: Optical grade glass
  • Adhesives: Low volatility (vacuum grade)
  • Type: Not plane mirror
  • Recommended reflector: 10771A
  • Mount used: 10785A
  • Beam bending possible: No
  • Interferometer movement allowed: ?
  • Included accessory: Alignment target simplifies setup
  • Related products: 10771A, 10785A, 55281A

click to collapse this panelPrice & Availability

Availability 6 week(s)

Usually arrives in: 6 week(s)

Prices for: India | Change Country/Area

Prices are subject to change without notice.

click to collapse this panelWhat's New more >

click to collapse this panelTraining & Events

None available for this product.

click to collapse this panelRelated Links