|
New!

N1913A EPMシリーズ・シングル・チャネル・パワー・メータ |
1 |
• U2000 Sensors -60 dBm to +44 dBm • N8480 Sensors -70 dBm to +44 dBm • 8480 Sensors -70 dBm to +44 dBm • E441XA CW Sensors -70 dBm to +20 dBm • E9300 Sensors -60 dBm to +44 dBm |
• U2000 Sensors 9kHz to 24 GHz • N8480 Sensors 100kHz to 50 GHz • 8480 Sensors 10 MHz to 50 GHz • E441XA CW Sensors 10 MHz to 33 GHz • E9300 Sensors 9 kHz to 24 GHz |
Up to 400 readings / second
|
• U2000 Series • N8480 Series • 8480 Series • E4410A Series • E9300 Series (E9320 Series NOT supported) |
• Measure average power |
Multiple connector types are available, power sensors dependent |
|
New!

N1914A EPMシリーズ・デュアル・チャネル・パワー・メータ |
2 |
• U2000 Sensors -60 dBm to +44 dBm • N8480 Sensors -70 dBm to +44 dBm • 8480 Sensors -70 dBm to +44 dBm • E441XA CW Sensors -70 dBm to +20 dBm • E9300 Sensors -60 dBm to +44 dBm |
• U2000 Sensors 9kHz to 24 GHz • N8480 Sensors 100kHz to 50 GHz • 8480 Sensors 10 MHz to 50 GHz • E441XA CW Sensors 10 MHz to 33 GHz • E9300 Sensors 9 kHz to 24 GHz |
Up to 200 readings / second on each channel
|
• U2000 Series • N8480 Series • 8480 Series • E4410A Series • E9300 Series (E9320 Series NOT supported) |
• Measure average power |
Multiple connector types are available, power sensors dependent |
|

N1911A Pシリーズ・シングル・チャネル・パワー・メータ |
1 |
N1920センサ:-35~+20 dBm * E9320センサ:-65~+20 dBm * E9300センサ:-60~+44 dBm * E441XAセンサ:-70~+20 dBm * 8480センサ:-70~+44 dBm |
• N8480 Sensors 100kHz to 50 GHz • 8480 Sensors 10 MHz to 50 GHz • E441XA CW Sensors 10 MHz to 33 GHz • E9300 Sensors 9 kHz to 24 GHz • E9320 Sensors 50 MHz to 18 GHz • N192X Sensors 50 MHz to 40 GHz |
1500
|
• 8484 Series • 8480 Series • E441xA Series • E9320 Series • E9300 Series • N192xA Series |
ピーク、ピーク・アベレージ比、平均パワー、立上がり/立下がり時間、パルス幅測定 ・ 内部ゼロ調整および校正 ・ 30 MHzビデオBW、100 Mサンプル/sでの連続サンプリング |
Multiple connector types are available, power sensors dependent |
|

N1912A Pシリーズ・デュアル・チャネル・パワー・メータ |
1 |
N1920センサ:-35~+20 dBm * E9320センサ:-65~+20 dBm * E9300センサ:-60~+44 dBm * E441XAセンサ:-70~+20 dBm * 8480センサ:-70~+44 dBm |
• N8480 Sensors 100kHz to 50 GHz • 8480 Sensors 10 MHz to 50 GHz • E441XA CW Sensors 10 MHz to 33 GHz • E9300 Sensors 9 kHz to 24 GHz • E9320 Sensors 50 MHz to 18 GHz • N192X Sensors 50 MHz to 40 GHz |
1500
|
• 8484 Series • 8480 Series • E441xA Series • E9320 Series • E9300 Series • N192xA Series |
ピーク、ピーク・アベレージ比、平均パワー、立上がり/立下がり時間、パルス幅測定 ・ 内部ゼロ調整および校正 ・ 30 MHzビデオBW、100 Mサンプル/sでの連続サンプリング |
Multiple connector types are available, power sensors dependent |
|

N8262A Pシリーズ・パワー・メータ(LXI対応) |
2 |
N1920センサ -35~+20 dBm * E9300センサ -60~+44 dBm * E441XAセンサ -70~+20 dBm * 8480センサ -70~+44 dBm |
• U2000 Sensors 9kHz to 24 GHz • N8480 Sensors 100kHz to 50 GHz • 8480 Sensors 10 MHz to 50 GHz • E441XA CW Sensors 10 MHz to 33 GHz • E9300 Sensors 9 kHz to 24 GHz • E9320 Sensors 50 MHz to 18 GHz • N192X Sensors 50 MHz to 40 GHz |
> 1500 読み取り/秒
|
• 8480 Series • E4410A Series • E9300 Series • N1920A Series |
· 小型でスリムなLXI-C準拠ピーク・パワー・メータ · LANベースの自動測定が可能 · N1911/12Aと機能/プログラミング・コード互換 |
Multiple connector types are available, power sensors dependent |
|

E4416A EPM-Pシリーズ・シングル・チャネル・パワー・メータ |
1 |
• N8480 Sensors -70 dBm to +44 dBm • 8480 Sensors -70 dBm to +44 dBm • E441XA CW Sensors -70 dBm to +20 dBm • E9300 Sensors -60 dBm to +44 dBm • E9320 Sensors -65 dBm to +20 dBm |
• N8480 Sensors 100kHz to 50 GHz • 8480 Sensors 10 MHz to 50 GHz • E441XA CW Sensors 10 MHz to 33 GHz • E9300 Sensors 9 kHz to 24 GHz • E9320 Sensors 50 MHz to 18 GHz |
up to 1000 readings/sec
|
• 8480 Series • E4410A Series • E9300 Series • E9320 Series |
measure peak, average and time-gated power |
Multiple connector types are available, power sensors dependent |
|

E4417A EPM-Pシリーズ、デュアル・チャネル・パワー・メータ |
2 |
• N8480 Sensors -70 dBm to +44 dBm • 8480 Sensors -70 dBm to +44 dBm • E441XA CW Sensors -70 dBm to +20 dBm • E9300 Sensors -60 dBm to +44 dBm • E9320 Sensors -65 dBm to +20 dBm |
• N8480 Sensors 100kHz to 50 GHz • 8480 Sensors 10 MHz to 50 GHz • E441XA CW Sensors 10 MHz to 33 GHz • E9300 Sensors 9 kHz to 24 GHz • E9320 Sensors 50 MHz to 18 GHz |
up to 1000 readings/sec
|
• 8480 Series • E4410A Series • E9300 Series • E9320 Series |
measure peak, average and time-gated power |
Multiple connector types are available, power sensors dependent |
|

E4418B EPMシリーズ・シングル・チャネル・パワー・メータ |
1 |
• 8480 Sensors -70 dBm to +44 dBm • E441XA CW Sensors -70 dBm to +20 dBm • E9300 Sensors -60 dBm to +44 dBm |
• N8480 Sensors 100kHz to 50 GHz • 8480 Sensors 10 MHz to 50 GHz • E441XA CW Sensors 10 MHz to 33 GHz • E9300 Sensors 9 kHz to 24 GHz
|
up to 200 readings/second
|
• 8480 Series • E4410A Series • E9300 Series (E9320 Series NOT supported) |
n/a |
Multiple connector types are available, power sensors dependent |
|

E4419B EPMシリーズ・デュアル・チャネル・パワー・メータ |
2 |
• 8480 Sensors -70 dBm to +44 dBm • E441XA CW Sensors -70 dBm to +20 dBm • E9300 Sensors -60 dBm to +44 dBm |
• N8480 Sensors 100kHz to 50 GHz • 8480 Sensors 10 MHz to 50 GHz • E441XA CW Sensors 10 MHz to 33 GHz • E9300 Sensors 9 kHz to 24 GHz |
up to 100 readings/second on each channel
|
• 8480 Series • E4410A Series • E9300 Series (E9320 Series NOT supported) |
n/a |
Multiple connector types are available, power sensors dependent |
|

U2000A 10 MHz~18 GHz USBパワー・センサ |
1 |
-60 dBm to +20 dBm |
10 MHz to 18 GHz |
110 readings / sec at Fast mode
|
N1913A/14A |
• Measure average power |
Type-N (m) |
|

U2000B 10 MHz~18 GHz USBパワー・センサ |
1 |
-30 dBm to +44 dBm |
10 MHz to 18 GHz |
110 readings / sec at Fast mode
|
N1913A/14A |
• Measure average power |
Type-N (m) |
|

U2000H 10 MHz~18 GHz USBパワー・センサ |
1 |
-50 dBm to +30 dBm |
10 MHz to 18 GHz |
110 readings / sec at Fast mode
|
N1913A/14A |
• Measure average power |
Type-N (m) |
|

U2001A 10 MHz~6 GHz USBパワー・センサ |
1 |
-60 dBm to +20 dBm |
10 MHz to 6 GHz |
110 readings / sec at Fast mode
|
N1913A/14A |
• Measure average power |
Type-N (m) |
|

U2001B 10 MHz~6 GHz USBパワー・センサ |
1 |
-30 dBm to +44 dBm |
10 MHz to 6 GHz |
110 readings / sec at Fast mode
|
N1913A/14A |
• Measure average power |
Type-N (m)
|
|

U2001H 10 MHz~6 GHz USBパワー・センサ |
1 |
-50 dBm to +30 dBm |
10 MHz to 6 GHz |
110 readings / sec at Fast mode
|
N1913A/14A |
• Measure average power |
Type-N (m) |
|

U2002A 50 MHz~24 GHz USBパワー・センサ |
1 |
-60 dBm to +20 dBm |
50 MHz to 24 GHz |
110 readings / sec at Fast mode
|
N1913A/14A |
• Measure average power |
3.5mm (m) |
|

U2002H 50 MHz~24 GHz USBパワー・センサ |
1 |
-50 dBm to +30 dBm |
50 MHz to 24 GHz |
110 readings / sec at Fast mode
|
N1913A/14A |
• Measure average power |
3.5mm (m) |
|

U2004A 9 kHz~6 GHz USBパワー・センサ |
1 |
-60 dBm to +20 dBm |
9 kHz to 6 GHz |
110 readings / sec at Fast mode
|
N1913A/14A |
• Measure average power |
Type-N (m) |
|

432A アナログ・パワー・メータ |
1 |
• Thermistors -30dBm to +10 dBm |
なし |
n/a
|
• Thermistors |
Analog meter |
なし |
|

53140 Series Microwave Counter/Power Meter/DVM, up to 46 GHz |
1 |
· 8480 Sensors -70 dBm to 44 dBm |
なし |
2
|
8480 Series |
Counter/power meter/DMM combination * saves space in system rack * excellent for microwave link maintenance * optional battery power |
なし |
|

N1918A パワー・アナライザ・マネージャ |
なし |
なし |
なし |
なし |
なし |
なし |
なし |