New!

N1913A EPM Series Single-Channel Power Meter |
1 |
• U2000 Sensors -60 dBm to +44 dBm • N8480 Sensors -70 dBm to +44 dBm • 8480 Sensors -70 dBm to +44 dBm • E441XA CW Sensors -70 dBm to +20 dBm • E9300 Sensors -60 dBm to +44 dBm |
• U2000 Sensors 9kHz to 24 GHz • N8480 Sensors 100kHz to 50 GHz • 8480 Sensors 10 MHz to 50 GHz • E441XA CW Sensors 10 MHz to 33 GHz • E9300 Sensors 9 kHz to 24 GHz |
Up to 400 readings / second
|
• U2000 Series • N8480 Series • 8480 Series • E4410A Series • E9300 Series (E9320 Series NOT supported) |
• Measure average power |
Multiple connector types are available, power sensors dependent |
|
New!

N1914A EPM Series Dual-Channel Power Meter |
2 |
• U2000 Sensors -60 dBm to +44 dBm • N8480 Sensors -70 dBm to +44 dBm • 8480 Sensors -70 dBm to +44 dBm • E441XA CW Sensors -70 dBm to +20 dBm • E9300 Sensors -60 dBm to +44 dBm |
• U2000 Sensors 9kHz to 24 GHz • N8480 Sensors 100kHz to 50 GHz • 8480 Sensors 10 MHz to 50 GHz • E441XA CW Sensors 10 MHz to 33 GHz • E9300 Sensors 9 kHz to 24 GHz |
Up to 200 readings / second on each channel
|
• U2000 Series • N8480 Series • 8480 Series • E4410A Series • E9300 Series (E9320 Series NOT supported) |
• Measure average power |
Multiple connector types are available, power sensors dependent |
|

N1911A P 시리즈 싱글 채널 파워 미터 |
1 |
• N1920 Sensors -35 to +20 dBm • E9320 Sensors -65 to +20 dBm • E9300 Sensors -60 to +44 dBm • E441XA Sensors -70 to +20 dBm • 8480 Sensors -70 to +44 dBm |
• N8480 Sensors 100kHz to 50 GHz • 8480 Sensors 10 MHz to 50 GHz • E441XA CW Sensors 10 MHz to 33 GHz • E9300 Sensors 9 kHz to 24 GHz • E9320 Sensors 50 MHz to 18 GHz • N192X Sensors 50 MHz to 40 GHz |
> 1500 readings/second
|
• 8484 Series • 8480 Series • E441xA Series • E9320 Series • E9300 Series • N192xA Series |
· Peak, pk-to-avg, average power, rise/fall time measurements · Internal zeroing and calibration · 30 MHz video BW, 100 MSa/s continuous sampling |
Multiple connector types are available, power sensors dependent |
|

N1912A P 시리즈 듀얼 채널 파워 미터 |
1 |
• N1920 Sensors -35 to +20 dBm • E9320 Sensors -65 to +20 dBm • E9300 Sensors -60 to +44 dBm • E441XA Sensors -70 to +20 dBm • 8480 Sensors -70 to +44 dBm |
• N8480 Sensors 100kHz to 50 GHz • 8480 Sensors 10 MHz to 50 GHz • E441XA CW Sensors 10 MHz to 33 GHz • E9300 Sensors 9 kHz to 24 GHz • E9320 Sensors 50 MHz to 18 GHz • N192X Sensors 50 MHz to 40 GHz |
> 1500 readings/second
|
• 8484 Series • 8480 Series • E441xA Series • E9320 Series • E9300 Series • N192xA Series |
· Peak, pk-to-avg, average power, rise/fall time measurements · Internal zeroing and calibration · 30 MHz video BW, 100 MSa/s continuous sampling |
Multiple connector types are available, power sensors dependent |
|

N8262A P시리즈 모듈러 파워 미터 (LXI-C 호환) |
2 |
N1920 센서 -35 ~ +20 dBm * E9300 센서 -60 - +44 dBm * E441XA 센서 -70 - +20 dBm * 8480 센서 -70 - +44 dBm |
• U2000 Sensors 9kHz to 24 GHz • N8480 Sensors 100kHz to 50 GHz • 8480 Sensors 10 MHz to 50 GHz • E441XA CW Sensors 10 MHz to 33 GHz • E9300 Sensors 9 kHz to 24 GHz • E9320 Sensors 50 MHz to 18 GHz • N192X Sensors 50 MHz to 40 GHz |
> 1500 판독/초
|
• 8480 Series • E4410A Series • E9300 Series • N1920A Series |
· 컴팩트 및 슬림형 LXI-C 호환 피크 파워 미터로 LAN 기반 자동 측정이 가능하며 N1911/12A 기능/프로그래밍 코드와 호환됨 |
Multiple connector types are available, power sensors dependent |
|

E4416A EPM-P 시리즈 단일 채널 파워 미터 |
1 |
사용불가 |
• N8480 Sensors 100kHz to 50 GHz • 8480 Sensors 10 MHz to 50 GHz • E441XA CW Sensors 10 MHz to 33 GHz • E9300 Sensors 9 kHz to 24 GHz • E9320 Sensors 50 MHz to 18 GHz |
사용불가
|
• 8480 Series • E4410A Series • E9300 Series • E9320 Series |
사용불가 |
Multiple connector types are available, power sensors dependent |
|

E4417A EPM-P 시리즈 이중 채널 파워 미터 |
2 |
• N8480 Sensors -70 dBm to +44 dBm • 8480 Sensors -70 dBm to +44 dBm • E441XA CW Sensors -70 dBm to +20 dBm • E9300 Sensors -60 dBm to +44 dBm • E9320 Sensors -65 dBm to +20 dBm |
• N8480 Sensors 100kHz to 50 GHz • 8480 Sensors 10 MHz to 50 GHz • E441XA CW Sensors 10 MHz to 33 GHz • E9300 Sensors 9 kHz to 24 GHz • E9320 Sensors 50 MHz to 18 GHz |
up to 1000 readings/sec
|
• 8480 Series • E4410A Series • E9300 Series • E9320 Series |
measure peak, average and time-gated power |
Multiple connector types are available, power sensors dependent |
|

E4418B EPM 시리즈 단일 채널 파워 미터 |
1 |
• 8480 Sensors -70 dBm to +44 dBm • E441XA CW Sensors -70 dBm to +20 dBm • E9300 Sensors -60 dBm to +44 dBm |
• N8480 Sensors 100kHz to 50 GHz • 8480 Sensors 10 MHz to 50 GHz • E441XA CW Sensors 10 MHz to 33 GHz • E9300 Sensors 9 kHz to 24 GHz
|
up to 200 readings/second
|
• 8480 Series • E4410A Series • E9300 Series (E9320 Series NOT supported) |
n/a |
Multiple connector types are available, power sensors dependent |
|

E4419B EPM 시리즈 이중 채널 파워 미터 |
2 |
• 8480 Sensors -70 dBm to +44 dBm • E441XA CW Sensors -70 dBm to +20 dBm • E9300 Sensors -60 dBm to +44 dBm |
• N8480 Sensors 100kHz to 50 GHz • 8480 Sensors 10 MHz to 50 GHz • E441XA CW Sensors 10 MHz to 33 GHz • E9300 Sensors 9 kHz to 24 GHz |
up to 100 readings/second on each channel
|
• 8480 Series • E4410A Series • E9300 Series (E9320 Series NOT supported) |
n/a |
Multiple connector types are available, power sensors dependent |
|

U2000A 10MHz - 18GHz USB 파워 센서 |
1 |
-60 dBm to +20 dBm |
10 MHz to 18 GHz |
110 readings / sec at Fast mode
|
N1913A/14A |
• Measure average power |
Type-N (m) |
|

U2000B 10 MHz - 18 GHz USB 파워 센서 |
1 |
-30 dBm to +44 dBm |
10 MHz to 18 GHz |
110 readings / sec at Fast mode
|
N1913A/14A |
• Measure average power |
Type-N (m) |
|

U2000H 10 MHz - 18 GHz USB 파워 센서 |
1 |
-50 dBm to +30 dBm |
10 MHz to 18 GHz |
110 readings / sec at Fast mode
|
N1913A/14A |
• Measure average power |
Type-N (m) |
|

U2001A 10MHz - 6GHz USB 파워 센서 |
1 |
-60 dBm to +20 dBm |
10 MHz to 6 GHz |
110 readings / sec at Fast mode
|
N1913A/14A |
• Measure average power |
Type-N (m) |
|

U2001B 10 MHz - 6 GHz USB 파워 센서 |
1 |
-30 dBm to +44 dBm |
10 MHz to 6 GHz |
110 readings / sec at Fast mode
|
N1913A/14A |
• Measure average power |
Type-N (m)
|
|

U2001H 10 MHz - 6 GHz USB 파워 센서 |
1 |
-50 dBm to +30 dBm |
10 MHz to 6 GHz |
110 readings / sec at Fast mode
|
N1913A/14A |
• Measure average power |
Type-N (m) |
|

U2002A 50MHz - 24GHz USB 파워 센서 |
1 |
-60 dBm to +20 dBm |
50 MHz to 24 GHz |
110 readings / sec at Fast mode
|
N1913A/14A |
• Measure average power |
3.5mm (m) |
|

U2002H 50 MHz - 24 GHz USB 파워 센서 |
1 |
-50 dBm to +30 dBm |
50 MHz to 24 GHz |
110 readings / sec at Fast mode
|
N1913A/14A |
• Measure average power |
3.5mm (m) |
|

U2004A 9 kHz - 6GHz USB 파워 센서 |
1 |
-60 dBm to +20 dBm |
9 kHz to 6 GHz |
110 readings / sec at Fast mode
|
N1913A/14A |
• Measure average power |
Type-N (m) |
|

432A 아날로그 파워 미터 |
사용불가 |
사용불가 |
사용불가 |
사용불가
|
• Thermistors |
사용불가 |
사용불가 |
|

53140 Series Microwave Counter/Power Meter/DVM, up to 46 GHz |
1 |
· 8480 Sensors -70 dBm to 44 dBm |
사용불가 |
2
|
8480 Series |
Counter/power meter/DMM combination * saves space in system rack * excellent for microwave link maintenance * optional battery power |
사용불가 |
|

N1918A 전력 분석 매니저 |
사용불가 |
사용불가 |
사용불가 |
사용불가 |
사용불가 |
사용불가 |
사용불가 |