PDF
2.33 MB
|
10 Gigabit Ethernet and the XAUI interface
This product note covers the use of the 71612C error performance analyzer when employed in testing the 10 Gigabit Ethernet and the XAUI interface.
|
2002-08-01
|
Application Note
|
|
|
|
PDF
747 KB
|
3325A Synthesizer / Function Generator and 1000 Computer HP-IB Programming Guide (AN 401-13)
This Application Note is for information only. Agilent no longer sells or supports these products.
|
1979-06-01
|
Application Note
|
|
|
|
PDF
8.34 MB
|
5370B Universal Time Interval Counter (AN 191-7)
This Application Note is for information only. Agilent no longer sells or supports these products.
|
1987-06-01
|
Application Note
|
|
|
|
|
8 Hints for Making Better Spectrum Analyzer Measurements (interactive format) (AN 1286-1)
This application note provides eight pertinent hints for making better spectrum analyzer measurements, such as measuring low level signals and identifying internal distortion products.
|
2009-07-09
|
Application Note
|
|
|
|
PDF
641 KB
|
8620C Sweep Oscillator and 1000 Computer HP-IB Programming Guide (AN 401-17)
This Application Note is for information only. Agilent no longer sells or supports these products.
|
1979-04-01
|
Application Note
|
|
|
|
PDF
572 KB
|
8660 Signal Generator and 1000 Computer HP-IB Programming Guide (AN 401-19)
This Application Note is for information only. Agilent no longer sells or supports these products.
|
1979-08-01
|
Application Note
|
|
|
|
PDF
613 KB
|
8672A Synthesized Signal Generator and 1000 Computer HP-IB Programming Guide (AN 401-13)
This Application Note is for information only. Agilent no longer sells or supports these products.
|
1979-07-01
|
Application Note
|
|
|
|
PDF
3.48 MB
|
8753 Mixer Measurements (PN 8753-2)
This Product Note describes several procedures and hardware setups for measuring the performance of a mixer or frequency translator
using the Agilent 8753B Vector Network Analyzer.
|
2000-11-01
|
Application Note
|
|
|
|
PDF
815 KB
|
A New Technique for Pulsed RF Measurements (AN 120)
This Application Note is for information only. Agilent no longer sells or supports these products.
|
1968-09-01
|
Application Note
|
|
|
|
PDF
3.83 MB
|
A Technique for Calibrating Phase Shifters to High Accuracy (AN 19)
This Application Note is for information only. Agilent no longer sells or supports these products.
|
1966-05-01
|
Application Note
|
|
|
|
PDF
1.2 MB
|
Accessing the 3582A Memory with HP-IB (AN 245-4)
This Application Note is for information only. Agilent no longer sells or supports these products.
|
1979-05-01
|
Application Note
|
|
|
|
PDF
2.73 MB
|
Advanced TDR Techniques (AN 62-3)
This Application Note is for information only. Agilent no longer sells or supports these products.
|
1990-04-01
|
Application Note
|
|
|
|
PDF
852 KB
|
Antenna / Radome Boresight Error Measurements (AN 110)
This Application Note is for information only. Agilent no longer sells or supports these products.
|
1968-10-01
|
Application Note
|
|
|
|
PDF
7.64 MB
|
Applications and Operations of the 8970A Noise Figure Meter (PN8970A-1)
Part Number: 08970-99000 (Nov81). The 8970A is a discontinued product; this product note is provided for information only.
|
1981-11-01
|
Application Note
|
|
|
|
PDF
1.75 MB
|
Audio Frequency Measurements with the 8556A-8552B Spectrum Analyzer (AN 134)
This Application Note is for information only. Agilent no longer sells or supports these products.
|
1971-06-01
|
Application Note
|
|
|
|
PDF
529 KB
|
Automated Noise Sideband Measurements using the 8568A Spectrum Analyzer (AN 270-2)
This Application Note is for information only. Agilent no longer sells or supports these products.
|
1980-03-01
|
Application Note
|
|
|
|
PDF
1.37 MB
|
Basic Microwave Measurements (AN 27)
This Application Note is for information only. Agilent no longer sells or supports these products.
|
1965-08-01
|
Application Note
|
|
|
|
PDF
1.06 MB
|
Battery Drain Analysis Improves Mobile-Device Operating Time
Using specialized tools and analysis techniques can help you create mobile-device designs that extend battery life and improve your productivity.
|
2007-02-01
|
Application Note
|
|
|
|
PDF
65 KB
|
Broadbanding the Shunt Pin Diode SPDT Switch (AN 957-1)
This Application Note is for information only. Agilent no longer sells or supports these products.
|
1996-01-01
|
Application Note
|
|
|
|
PDF
865 KB
|
CATV Proof of Performance (150-6)
This Application Note is for information only. Agilent no longer sells or supports these products.
|
1974-04-01
|
Application Note
|
|
|
|
PDF
628 KB
|
Comb Generator Simplifies Multiplier Design (AN 983)
This Application Note is for information only. Agilent no longer sells or supports these products.
|
1981-02-01
|
Application Note
|
|
|
|
PDF
537 KB
|
Configuration of a Two-Tone Sweeping Generator (AN 312-1)
This Application Note is for information only. Agilent no longer sells or supports these products.
|
1981-12-01
|
Application Note
|
|
|
|
PDF
4.85 MB
|
Contribution of clocks to the BIH's International Atomic Time Scale (IATS) (AN 52-4)
This Application Note is for information only. Agilent no longer sells or supports these products.
|
1986-06-01
|
Application Note
|
|
|
|
PDF
960 KB
|
CRT Photography and X-Y Recording Techniques (AN 150-5)
This Application Note is for information only. Agilent no longer sells or supports these products.
|
1973-05-01
|
Application Note
|
|
|
|
PDF
484 KB
|
Designing a Custom Interface for a Logic Analyzer using User Definable Design Tools (AN 1244-2)
This Application Note is for information only. Agilent no longer sells or supports these products.
|
1993-08-01
|
Application Note
|
|