U2004A 9 kHz - 6 GHz USB Power Sensor |
1 |
-60 dBm to +20 dBm |
9 kHz to 6 GHz |
110 readings / sec at Fast mode
|
N1913A/14A |
• Measure average power |
Type-N (m) |
|

U2002H 50 MHz - 24 GHz USB Power Sensor |
1 |
-50 dBm to +30 dBm |
50 MHz to 24 GHz |
110 readings / sec at Fast mode
|
N1913A/14A |
• Measure average power |
3.5mm (m) |
|

U2002A 50 MHz - 24 GHz USB Power Sensor |
1 |
-60 dBm to +20 dBm |
50 MHz to 24 GHz |
110 readings / sec at Fast mode
|
N1913A/14A |
• Measure average power |
3.5mm (m) |
|

U2001H 10 MHz - 6 GHz USB Power Sensor |
1 |
-50 dBm to +30 dBm |
10 MHz to 6 GHz |
110 readings / sec at Fast mode
|
N1913A/14A |
• Measure average power |
Type-N (m) |
|

U2001B 10 MHz - 6 GHz USB Power Sensor |
1 |
-30 dBm to +44 dBm |
10 MHz to 6 GHz |
110 readings / sec at Fast mode
|
N1913A/14A |
• Measure average power |
Type-N (m)
|
|

U2001A 10 MHz - 6 GHz USB Power Sensor |
1 |
-60 dBm to +20 dBm |
10 MHz to 6 GHz |
110 readings / sec at Fast mode
|
N1913A/14A |
• Measure average power |
Type-N (m) |
|

U2000H 10 MHz - 18 GHz USB Power Sensor |
1 |
-50 dBm to +30 dBm |
10 MHz to 18 GHz |
110 readings / sec at Fast mode
|
N1913A/14A |
• Measure average power |
Type-N (m) |
|

U2000B 10 MHz - 18 GHz USB Power Sensor |
1 |
-30 dBm to +44 dBm |
10 MHz to 18 GHz |
110 readings / sec at Fast mode
|
N1913A/14A |
• Measure average power |
Type-N (m) |
|

U2000A 10 MHz - 18 GHz USB Power Sensor |
1 |
-60 dBm to +20 dBm |
10 MHz to 18 GHz |
110 readings / sec at Fast mode
|
N1913A/14A |
• Measure average power |
Type-N (m) |
|

N8262A P-Series Modular Power Meter (LXI-C compliant) |
2 |
• N1920 Sensors -35 to +20 dBm • E9300 Sensors -60 to +44 dBm • E441XA Sensors -70 to +20 dBm • 8480 Sensors -70 to +44 dBm |
• U2000 Sensors 9kHz to 24 GHz • N8480 Sensors 100kHz to 50 GHz • 8480 Sensors 10 MHz to 50 GHz • E441XA CW Sensors 10 MHz to 33 GHz • E9300 Sensors 9 kHz to 24 GHz • E9320 Sensors 50 MHz to 18 GHz • N192X Sensors 50 MHz to 40 GHz |
> 1500 readings/second
|
• 8480 Series • E4410A Series • E9300 Series • N1920A Series |
· compact, slim, LXI-C compliant peak power meter · enables LAN-based automated measurements · N1911/12A features/programming codes compatible |
Multiple connector types are available, power sensors dependent |
|

N1918A Power Analysis Manager |
n/a |
n/a |
n/a |
n/a |
n/a |
n/a |
n/a |
|
New!

N1914A EPM Series Dual-Channel Power Meter |
2 |
• U2000 Sensors -60 dBm to +44 dBm • N8480 Sensors -70 dBm to +44 dBm • 8480 Sensors -70 dBm to +44 dBm • E441XA CW Sensors -70 dBm to +20 dBm • E9300 Sensors -60 dBm to +44 dBm |
• U2000 Sensors 9kHz to 24 GHz • N8480 Sensors 100kHz to 50 GHz • 8480 Sensors 10 MHz to 50 GHz • E441XA CW Sensors 10 MHz to 33 GHz • E9300 Sensors 9 kHz to 24 GHz |
Up to 200 readings / second on each channel
|
• U2000 Series • N8480 Series • 8480 Series • E4410A Series • E9300 Series (E9320 Series NOT supported) |
• Measure average power |
Multiple connector types are available, power sensors dependent |
|
New!

N1913A EPM Series Single-Channel Power Meter |
1 |
• U2000 Sensors -60 dBm to +44 dBm • N8480 Sensors -70 dBm to +44 dBm • 8480 Sensors -70 dBm to +44 dBm • E441XA CW Sensors -70 dBm to +20 dBm • E9300 Sensors -60 dBm to +44 dBm |
• U2000 Sensors 9kHz to 24 GHz • N8480 Sensors 100kHz to 50 GHz • 8480 Sensors 10 MHz to 50 GHz • E441XA CW Sensors 10 MHz to 33 GHz • E9300 Sensors 9 kHz to 24 GHz |
Up to 400 readings / second
|
• U2000 Series • N8480 Series • 8480 Series • E4410A Series • E9300 Series (E9320 Series NOT supported) |
• Measure average power |
Multiple connector types are available, power sensors dependent |
|

N1912A P-Series Dual Channel Power Meter |
1 |
• N1920 Sensors -35 to +20 dBm • E9320 Sensors -65 to +20 dBm • E9300 Sensors -60 to +44 dBm • E441XA Sensors -70 to +20 dBm • 8480 Sensors -70 to +44 dBm |
• N8480 Sensors 100kHz to 50 GHz • 8480 Sensors 10 MHz to 50 GHz • E441XA CW Sensors 10 MHz to 33 GHz • E9300 Sensors 9 kHz to 24 GHz • E9320 Sensors 50 MHz to 18 GHz • N192X Sensors 50 MHz to 40 GHz |
> 1500 readings/second
|
• 8484 Series • 8480 Series • E441xA Series • E9320 Series • E9300 Series • N192xA Series |
· Peak, pk-to-avg, average power, rise/fall time measurements · Internal zeroing and calibration · 30 MHz video BW, 100 MSa/s continuous sampling |
Multiple connector types are available, power sensors dependent |
|

N1911A P-Series Single Channel Power Meter |
1 |
• N1920 Sensors -35 to +20 dBm • E9320 Sensors -65 to +20 dBm • E9300 Sensors -60 to +44 dBm • E441XA Sensors -70 to +20 dBm • 8480 Sensors -70 to +44 dBm |
• N8480 Sensors 100kHz to 50 GHz • 8480 Sensors 10 MHz to 50 GHz • E441XA CW Sensors 10 MHz to 33 GHz • E9300 Sensors 9 kHz to 24 GHz • E9320 Sensors 50 MHz to 18 GHz • N192X Sensors 50 MHz to 40 GHz |
> 1500 readings/second
|
• 8484 Series • 8480 Series • E441xA Series • E9320 Series • E9300 Series • N192xA Series |
· Peak, pk-to-avg, average power, rise/fall time measurements · Internal zeroing and calibration · 30 MHz video BW, 100 MSa/s continuous sampling |
Multiple connector types are available, power sensors dependent |
|

E4419B EPM Series Dual-Channel Power Meter |
2 |
• 8480 Sensors -70 dBm to +44 dBm • E441XA CW Sensors -70 dBm to +20 dBm • E9300 Sensors -60 dBm to +44 dBm |
• N8480 Sensors 100kHz to 50 GHz • 8480 Sensors 10 MHz to 50 GHz • E441XA CW Sensors 10 MHz to 33 GHz • E9300 Sensors 9 kHz to 24 GHz |
up to 100 readings/second on each channel
|
• 8480 Series • E4410A Series • E9300 Series (E9320 Series NOT supported) |
n/a |
Multiple connector types are available, power sensors dependent |
|

E4418B EPM Series Single-Channel Power Meter |
1 |
• 8480 Sensors -70 dBm to +44 dBm • E441XA CW Sensors -70 dBm to +20 dBm • E9300 Sensors -60 dBm to +44 dBm |
• N8480 Sensors 100kHz to 50 GHz • 8480 Sensors 10 MHz to 50 GHz • E441XA CW Sensors 10 MHz to 33 GHz • E9300 Sensors 9 kHz to 24 GHz
|
up to 200 readings/second
|
• 8480 Series • E4410A Series • E9300 Series (E9320 Series NOT supported) |
n/a |
Multiple connector types are available, power sensors dependent |
|

E4417A EPM-P Series Dual-Channel Power Meter |
2 |
• N8480 Sensors -70 dBm to +44 dBm • 8480 Sensors -70 dBm to +44 dBm • E441XA CW Sensors -70 dBm to +20 dBm • E9300 Sensors -60 dBm to +44 dBm • E9320 Sensors -65 dBm to +20 dBm |
• N8480 Sensors 100kHz to 50 GHz • 8480 Sensors 10 MHz to 50 GHz • E441XA CW Sensors 10 MHz to 33 GHz • E9300 Sensors 9 kHz to 24 GHz • E9320 Sensors 50 MHz to 18 GHz |
up to 1000 readings/sec
|
• 8480 Series • E4410A Series • E9300 Series • E9320 Series |
measure peak, average and time-gated power |
Multiple connector types are available, power sensors dependent |
|

E4416A EPM-P Series Single Channel Power Meter |
1 |
• N8480 Sensors -70 dBm to +44 dBm • 8480 Sensors -70 dBm to +44 dBm • E441XA CW Sensors -70 dBm to +20 dBm • E9300 Sensors -60 dBm to +44 dBm • E9320 Sensors -65 dBm to +20 dBm |
• N8480 Sensors 100kHz to 50 GHz • 8480 Sensors 10 MHz to 50 GHz • E441XA CW Sensors 10 MHz to 33 GHz • E9300 Sensors 9 kHz to 24 GHz • E9320 Sensors 50 MHz to 18 GHz |
up to 1000 readings/sec
|
• 8480 Series • E4410A Series • E9300 Series • E9320 Series |
measure peak, average and time-gated power |
Multiple connector types are available, power sensors dependent |
|

53140 Series Microwave Counter/Power Meter/DVM, up to 46 GHz |
1 |
· 8480 Sensors -70 dBm to 44 dBm |
n/a |
2
|
8480 Series |
Counter/power meter/DMM combination * saves space in system rack * excellent for microwave link maintenance * optional battery power |
n/a |
|

432A Analog Power Meter |
1 |
• Thermistors -30dBm to +10 dBm |
n/a |
n/a
|
• Thermistors |
Analog meter |
n/a |