86100C Infiniium DCA-J Wideband Oscilloscope Mainframe
| Product Status: | Discontinued | Currently Supported |
|---|---|
| Supported Until: | 1 September 2016 |
No replacement found for this product.
Refine the List
By Type of Content
- Specifications (5)
- Manuals (5)
- Application Notes (20)
- Brochures & Competitive Overviews (12)
- Demos (2)
- Catalogs (1)
26-45 of 45
| Complete solutions for characterization, debug, compliance test of HDMI designs
This brochure discusses test solutions for HDMI. Thorough characterization and validation of HDMI-based designs
Brochure 2007-10-19 |
|
| Precision Jitter Analysis Using the Agilent 86100C DCA-J (PN 86100C-1)
This product note provides a guide to making jitter measurements with the Agilent 86100C DCA-J.
Application Note 2007-03-07 |
|
| 86100C Infiniium DCA-J Brochure
The 86100C Infiniium DCA-J is four high-performance instruments in one. It's a general purpose wide-bandwidth oscilloscope, a digital communications analyzer, a time-domain reflectometer, and a jitter analyzer.
Brochure 2007-01-12 |
|
| Signal Integrity Analysis Series Part 1: Single-Port TDR, TDR/TDT, & 2-Port TDR
This Application Note focuses on part 1: those which use a single-port TDR, those which use TDR/TDT, and those which use 2-port TDR.
Application Note 2007-01-01 |
|
| Comparison of Different Jitter Analysis Techniques With a Precision Transmitter
This white paper describes how various jitter analysis techniques give dissimilar results. Which is right? We built a precision jitter transmitter to compare results of different techniques where test sets were exposed to known levels of jitter.
Application Note 2006-04-06 |
|
| Equalization: The Correction and Analysis of Degraded Signals
This whitepaper introduces engineers to the concepts of equalization and terms used in the development of emerging technologies that use standard materials (e.g., FR4) for buses and backplanes at ever higher rates.
Application Note 2005-09-15 |
|
| Improved Method for Characterizing and Modeling Gigabit Flex-Circuit Based Interconnects
This paper describes sophisticated, time-domain methods of accurately predicting time- and frequency-domain high-speed signal characteristics.
Application Note 2005-09-08 |
|
| Total Jitter Measurements at Low Probability Levels, Using Optimized BERT Scan Method
This paper describes an optimized technique based on probabliity and statistics theory that enables accurate TJ measurements at the 1e-12 bit error ratio level in about 20 minutes at 10 Gbit/s.
Application Note 2005-07-11 |
|
| 86100A/B/C Series Plug-In Modules Installation Guide
This installation guide is for the 86100 series of plug-in modules designed for use with the Infiniium DCA Agilent 86100A/B/C wide-bandwidth oscilloscopes.
Installation Manual 2005-07-01 |
|
| Precision Jitter Transmitter
This paper introduces a precisely calibrated jitter source capable of applying a wide variety of jitter signals in different combinations at adjustable amplitudes. The system, calibration techniques, and examples are discussed.
Application Note 2005-06-20 |
|
| Jitter Analysis: The Dual-Dirac Model, RJ/DJ, and Q-Scale
This paper provides a complete description of the dual-Dirac model, how it is used in technology standards and a summary of how it is applied on different types of test equipment.
Application Note 2005-06-15 |
|
| Advanced Jitter Generation and Analysis Product Note
This product note shows how the Agilent pulse generators can be used with the DCA-J Oscilloscope.
Application Note 2004-10-04 |
|
| High Precision Time Domain Reflectometry (AN 1304-7)
Techniques for achieving the highest possible accuracy and resolution in signal integrity impedance measurements
Application Note 2003-10-27 |
|
| High-Precision TDR with the Agilent 86100 DCA & Picosecond Pulse Labs 4020 Source Enhancement Module
Learn how to build a high-precision time-domain reflectometry/time-domain transmission measurement system.
Application Note 2003-09-12 |
|
| Improving Optical Transceiver Extinction Ratio Measurement Accuracy
This paper discusses how to improve optical transceiver extinction ratio measurement accuracy by using reference receiver correction factors.
Application Note 2003-07-23 |
|
| Time Domain Reflectometry Theory (AN 1304-2)
This application note discusses the fundamentals of TDR and then relates these fundamentals to the parameters that can be measured in actual test situations.
Application Note 2002-08-29 |
|
| 40 Gb/s and Return-to-Zero Measurements Using the 86100A Infiniium DCA (PN 86100-3)
This note describes the evolution of the Agilent 86100A Infiniium DCA for 40 Gb/s test and how measurement requirements have been implemented in the instrument through improved hardware and firmware.
Application Note 2001-11-15 |
|
| Need to test 40 Gb/s?
This brochure describes solutions for testing at 40 Gb/s. These solutions can be used whether you are developing fiber-optic components, or verifying system performance.
Brochure 2001-10-02 |
|
| Rambus Product Overview
This product overview describes TDR for use in Rambus applications. The 86100A Infiniium DCA is a TDR oscilloscope which measures impedance verses distance (or time).
Technical Overview 2000-11-01 |
|
| Measuring High Power Waveforms with the 86100A DCA and the 86101A or 86103A Reference Receiver
Product Note 86100-2 discusses the Agilent 86100A Digital Communications Analyzer (DCA)with the 86101A/103A plug-in module, designed to perform Gigabit Ethernet and Fibre Channel compliance testing.
Application Note 2000-06-14 |
|