DSO5054A 5000 Series Oscilloscope: 500 MHz, 4 channels

Produkt Status: Derzeit bestellbar | Support verfügbar
Produkt-Upgrades: Hardware-, Software- und Firmware-Upgrades

FAQ (Häufig gestellte Fragen)

Sprache:Deutsch | English | Beide

1-25 von 30

Sortieren:

Ergebnisse

Titel/Beschreibung Datum Typ
Can I automatically position the Y1 and Y2 cursors to the voltage values at X1 and X2?
Yes, using SCPI remote programming commands, follow these steps...
2008-09-30 FAQ
Can I program a waveform captured by my oscilloscope into an Agilent arbitrary waveform generator?
Yes. The free IntuiLink Waveform Editor software will download waveform data from Agilent Infiniium, 6000 series, and 54600 series oscilloscopes and send the data to the an Agilent 33120A, 33210A, 33220A, or 33250A generator.
2008-08-29 FAQ
Can I use the Quick Print button to quickly save my waveforms into the USB thumbdrive?
Yes, but with software version 5.10 and above you have to enable the feature...
2008-09-30 FAQ
Can my 54600-series or 6000-series scope use channels 3 and 4 for XY mode or math functions?
These oscilloscopes can perform math functions such as FFT, integration, and differentiation on any analog channel or even on another math function. But they cannot use channel 3 or 4 for XY mode, addition, subtraction, or multiplication.
2006-11-04 FAQ
Can the 6000 Series oscilloscopes make floating measurements?
Like most other digitizing oscilloscopes, the new 6000 Series is not designed to offer floating measurement by itself. With 6000 Series you can make floating or differential measurements using a differential probe.
2006-11-04 FAQ
Do the mean, min, and max values of the InfiniiVision oscilloscopes measurement statistics refer to one signal on the screen or all previously captured signals?
They refer to the "Count" number of captured waveforms ...
2009-03-30 FAQ
How can I password protect my InfiniiVisoni scope on the LAN?
Select Configure Network, then select Modify Configuration.
2009-04-18 FAQ
How can I save comma separated variable (CSV) data to my USB thumb drive?
Set this up in Utility -> Print Config.
2006-11-04 FAQ
How do I connect my InfiniiVision oscilloscope directly to a PC via the LAN interface?
To establish a point-to-point LAN connection, you will need either a PC with an Auto-MDIX network adapter or a crossover (not straight-through) LAN cable.
2009-04-13 FAQ
How do I control my InfiniiVision oscilloscope from a web browser?
Connect to LAN, type scope's IP address in browser, select Browser Web Control, Remote Front Panel.
2009-04-16 FAQ
How do I control my oscilloscope from Microsoft Excel?
2007-01-05 FAQ
How do I determine or adjust the sample rate of my 6000-series oscilloscope?
To determine the sample rate, press the Main/Delayed button. The scope will display the current sample rate in the lower left portion of the display.
2006-12-04 FAQ
How do I establish a peer-to-peer connection between my PC and an InfiniiVision 5000/6000/7000 Series oscilloscope?
There are two methods ...
2008-10-07 FAQ
How do I save a screen image from my 5000/6000/7000-series InfiniiVision oscilloscope to a USB storage device?
These instructions assume that your scope has system software version 05.00 or later (see Utility | Service | About Oscilloscope -> System version to see your scope’s version).
2009-04-17 FAQ
How do I save deep memory waveform data from my InfiniiVision oscilloscope to a USB storage device?
Use half-channel mode and ASCII XY, ALB, or BIN format. Within the "Save" menu, press Settings and select the max number of points. Make sure you are at a slow enough time/div setting that all the points are on screen, and then press Single.
2009-03-23 FAQ
How do I transfer waveforms, screen images, and measurements from my InfiniiVision oscilloscope to a PC using IntuiLink Data Capture?
Agilent’s free IntuiLink Data Capture software provides an easy way to transfer deep-memory waveform data, screen images, and measurements from your oscilloscope to your PC via the USB, LAN, or GPIB interface.
2009-05-05 FAQ
How does one understand the "Count" in InfiniiVision oscilloscope measurement statistics?
"Count" refers to the waveform count from the time Statistics are enabled ...
2009-03-30 FAQ
How often should I send in my oscilloscope for calibration?
2006-12-04 FAQ
I have purchased the Segmented Memory option, N5454A, for my InfiniiVision oscilloscope. However, I can’t find the feature in the menus. What can I do?
You need to upgrade your oscilloscope to the latest firmware...
2009-01-07 FAQ
In the user calibration of InfiniiVision 5000/6000/7000 Series oscilloscopes, what accessories are needed, and what is the procedure?
Here are the required accessories, and the procedure is at ...
2008-10-07 FAQ
Is it necessary to eliminate any skew between the voltage and current probes? How can I compensate for different delays in probes when using my InfiniiVision oscilloscope?
Yes, it is necessary to eliminate skew if your measured time intervals are in the ns range...
2008-09-30 FAQ
What is the amplitude accuracy of my oscilloscope?
When oscilloscope manufacturers specify vertical accuracy, they typically only mention bandwidth and DC accuracy. The bandwidth specification addresses the AC accuracy. Tighter AC accuracy specifications are very uncommon.
2006-11-04 FAQ
What is the function of the "10 MHz REF" port on my 6000-series oscilloscope?
You can use this port as either an input for an external 10 MHz reference signal, or as an output for the internal reference signal.
2007-01-23 FAQ
What is the purpose of the internal g(t) function available in the Math > Function menu of InfiniiVision 5000/6000/7000 Series Oscilloscopes?
The internal g(t) function can be used as a source of the displayed f(t) function ...
2008-10-07 FAQ
When using TV trigger mode with an Agilent oscilloscope, can I trigger only on even or odd fields?
Yes. All current Agilent scopes with TV triggering are capable of exclusively triggering on odd or even fields.
2006-12-04 FAQ