FAQ
|
|
|
|
|
Can I use the 11683A range calibrator for the performance test of P-Series Power Meter?
The P-Series have a built in range calibrator that allows the peak and average paths to be verified without the need for any external equipment.
|
2009-05-06
|
FAQ
|
|
|
|
|
How can I use a computer to monitor when the power meter is done with a Secure Erase?
The “*OPC?” command can be used with a long IO timeout.
|
2009-10-20
|
FAQ
|
|
|
|
|
How do I convert dBm to dBmV since power meter display unit is in dBm?
dBmV = dBm + 47
|
2009-11-08
|
FAQ
|
|
|
|
|
How do I convert percentage(linear) to dB(logarithmic) since most the accuracy value stated in power meter datasheet is in percentage?
dB = 0.0432
|
2009-10-20
|
FAQ
|
|
|
|
|
How do I set the Rise and Fall Times reference level on my N1911A/N1912A P-Series Power Meter?
To set the Rise and Fall Times reverence level on your N1911A or N1912A P-Series Power Meter, you need the firmware A.02.01 or above….
|
2008-09-25
|
FAQ
|
|
|
|
|
When will the E4416/7A, N1911/2A and N8262A Power Meters comply with the RoHS standard?
The E4416/E4417A, N1911/N1912A and N8262A Power Meters will gradually comply with the RoHS standard from the year 2012 onwards.
|
2009-02-04
|
FAQ
|
|
|
|
|
Which of Agilent's power sensors and power meters are compatible with each other?
The following table shows the compatiblitiy between Agilent power sensors and power meters….
|
2008-10-29
|
FAQ
|
|
|
|
|
Which of Agilent's sensor cables and power meters are compatible with each other?
The table given here shows the compatibility between Agilent's sensor cables and power meters:….
|
2009-02-27
|
FAQ
|
|
|
|
|
Why am I getting this message: "Certain features in the instrument firmware are currently not supported. Please refer to Agilent Web FAQ" when using my power meter and power sensor together with the N1918A Power Analysis Manager?
The message "Certain features in the instrument firmware are currently not supported. Please refer to Agilent Web FAQ" appears because....
|
2009-01-12
|
FAQ
|
|
|
|
|
Why do my N1911A and N1912A Power Meters display a message that says the analogue scale is over the range?
The N1911A and N1912A Power Meters display a message saying the analogue scale is over the range because the scale is set at a default….
|
2009-08-25
|
FAQ
|
|
|
|
|
Why does the N1911A/12A Power Meter automatically reset?
The N1911A/12A Power Meter automatically resets if there is unstable voltage transient in the power line….
|
2008-09-25
|