89600 VSA and X-Series analyzer compatibility matrix
Supported versions listed here
|
2009-10-22
|
FAQ
|
|
|
|
|
Can I add a DC blocking capacitor to the baseband I/Q inputs on my N9020A, MXA Signal Analyzer?
Yes, additional information can be found here...
|
2008-09-23
|
FAQ
|
|
|
|
|
Can I change the Windows XP localized language to another language other than English in the X-Series (PXA/MXA/EXA/CXA) Signal Analyzer?
No, currently Agilent does not support a local language other than English.
|
2009-09-26
|
FAQ
|
|
|
|
|
Can I install the latest Microsoft Windows Updates and Service Packs on my X-Series Signal Analyzer?
Yes, Agilent recommends installing Microsoft Windows Updates to address known operating system issues and help protect your instrument and your network against known security threats.
|
2009-09-26
|
FAQ
|
|
|
|
|
Can I use the N9020A MXA to demodulate the MIMO signals with fading?
No. Although the Spectrum or Signal Analyzer such as N9020A MXA or N9010A EXA, which is based on the principle of “super-heterodyne receiver” mainly to convert higher frequencies to measurable quantities, it is not the golden signal receiver as in the real communication system.
|
2009-11-13
|
FAQ
|
|
|
|
|
Do I need a keyboard and mouse to operate the Agilent X-Series (PXA/MXA/EXA/CXA) Signal Analyzers?
No. However, since this is a Windows based instrument it is easier to navigate various windows using a mouse.
|
2009-09-26
|
FAQ
|
|
|
|
|
Does the operator need to force the auto alignment to run each day to ensure the X-Series (PXA/MXA/EXA/CXA) Signal Analyzer is meeting published specifications?
No, the factory power on configuration has the auto-alignment process turned on...
|
2009-09-26
|
FAQ
|
|
|
|
|
For MIMO testing with 2-MXAs, does the 89601A VSA software need option BHE for both MXAs?
No, in this case, the 89601A option BHE is only need for the VSA that is acting as the controlling PC. If VSA is run inside of the MXAs, that one needs a BHE option. If VSA is running on an external PC, that PC’s VSA needs the BHE option.
|
2009-11-13
|
FAQ
|
|
|
|
|
How can I convert the X-Series (MXA/EXA/CXA) Signal Analyzer from the bench top to Portable configuration?
There is an upgrade option to change the configuration from bench top to portable. Details found here...
|
2009-09-26
|
FAQ
|
|
|
|
|
How do I convert the X-Series (MXA/EXA/CXA) Signal Analyzer from the Portable configuration to the bench top?
An upgrade option is not supported, but individual items can be ordered. Details found here...
|
2009-09-26
|
FAQ
|
|
|
|
|
How do I get Instrument Drivers for Agilent Test & Measurement Products?
From the CD shipped with the instrument or from the product technical support web page for the instrument.
|
2009-05-01
|
FAQ
|
|
|
|
|
How do I install a license key file into the Agilent X-Series (PXA/MXA/EXA/CXA)Signal Analyzer?
Process steps found here...
|
2009-09-26
|
FAQ
|
|
|
|
|
How do I perform a serial poll to determine when a sweep is complete on my Agilent X-Series Signal Analyzer?
Information found here...
|
2009-11-11
|
FAQ
|
|
|
|
|
How do I remotely control the Measure @ Marker function of the EMC Option in the N9000A, N9010A, N9020A or N9030A X-Series Signal Analyzers?
Use the remote command :CALC:MARK:FUNC:MAM? or see content of this FAQ for further details and an example VEE program...
|
2009-09-26
|
FAQ
|
|
|
|
|
How do I remotely program my Agilent X-Series (PXA/MXA/EXA/CXA) Signal Analyzer to remove instrument noise from the phase noise?
Sample program found here...
|
2009-09-26
|
FAQ
|
|
|
|
|
How do I remotely program my Agilent X-Series Signal Analyzer in C to use Relative Band Power Markers?
Sample program found here...
|
2009-11-11
|
FAQ
|
|
|
|
|
How do I remotely program my Agilent X-Series Signal Analyzer to set different types of trace detectors and couple markers?
Sample program found here...
|
2009-11-11
|
FAQ
|
|
|
|
|
How do I remotely program my Agilent X-Series, ESA, PSA Signal Analyzer to Transfer Trace data using VEE?
The attached program demonstrates how to transfer trace in in several formats including ASCII, REAL and Integer.
|
2009-11-11
|
FAQ
|
|
|
|
|
How do I remotely program my Agilent X-Series, ESA/PSA Series Signal Analyzer to transfer binary block trace data in Visual Basic 6?
Click here for information on transfering binary block trace data.
|
2009-11-11
|
FAQ
|
|
|
|
|
How do I remotely program my spectrum or vector signal analyzer?
Instructions, examples, and references for remotely programming your spectrum analyzer.
|
2009-11-16
|
FAQ
|
|
|
|
|
How do I remotely transfer screen images from my Agilent X-Series (PXA/MXA/EXA/CXA) Signal Analyzer using Visual Basic 6?
Sample program found here...
|
2009-09-26
|
FAQ
|
|
|
|
|
How do I remotely transfer screen images from my Agilent X-Series Signal Analyzer using VEE?
Sample program found here...
|
2009-11-11
|
FAQ
|
|
|
|
|
How do I upgrade my Agilent MXA Signal Analyzer (N9020A)?
Find Information on Hardware Options, Measurement Applications, etc....
|
2009-08-24
|
FAQ
|
|
|
|
|
How do I use the Service Request method (SRQ) to determine if the X-Series, ESA and PSA SIgnal Analyzers measurement is complete or has an error message using ANSI C or Visual C++?
Click here for information on the Service Request query to determine when a measurement is complete.
|
2009-11-11
|
FAQ
|
|
|
|
|
How does the N9020A MXA with N9082A do the PvT measurement?
For additional information, click here...
|
2009-11-13
|
FAQ
|
|